Product Glance Value
Model S19e XP Hyd.
Sub Version
Crypto algorithm/coins SHA256|BTC/BCH/BSV
Typical hashrate, TH/s(1-1) 251
Power on wall @35(1-2), Watt(1-1) 240
Power efficiency on wall@35(1-2), J/T(1-1) 10

Frequently Asked Questions (FAQ)

  • Q: What is the recommended coolant for the S19e XP Hyd.?
    A: The recommended coolants are Antifreeze, Pure water, or Deionized water based on the specified pH values.

Specification

Product Glance Value
Model S19e XP Hyd.
Sub 251T 240T
Version 10
Crypto algorithm/coins SHA256|BTC/BCH/BSV
Typical hash rate, TH/s(1-1) 251 240
Power on wall @35℃(1-2), Watt(1-1) 5522 5280
Power efficiency on wall@35℃(1-2), J/T(1-1) 22

Detailed Characteristics

Detailed Characteristics Value
Power supply
Phase 3
Input voltage, Volt(2-1) 380~415
Input frequency range, Hz 50~60
Input max current, Amp 12
Hardware configuration
Network connection mode RJ45 Ethernet 10/100M
Server size (length*width*height, w/o package), mm 410*170*209
Server size (length*width*height, with package), mm 570*316*430
Net weight, kg 12.8
Gross weight, kg 14.1
Environment requirements
Inlet coolant temperature, °C 20~50
Coolant flow, L/min 8.0~10.0
Coolant pressure, bar ≤3.5
Working Coolant (2-2) Antifreeze/ Pure water/ Deionized water
Coolant pH value Antifreeze: 7.0~9.0 Prue water: 6.5~7.5

Deionized water8.5~9.5

Diameter of Coolant pipe connector, mm OD10
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%

Notes:

  1. The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by 3%, and the actual power on wall and power efficiency on wall fluctuate by 5%.
  2. Inlet coolant temperature.
  3. Caution: Wrong input voltage may cause server damaged.
  4. For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!

Performance Curve

  1. Hashrate vs. Inlet Coolant Temperature.BITMAIN-S19e-XP-Hyd-Algorithm-With-Maximum-Hashrate-1
  2. Power Efficiency vs. Inlet Coolant Temperature.BITMAIN-S19e-XP-Hyd-Algorithm-With-Maximum-Hashrate-2
  3. The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by 3%, and the actual power efficiency on wall fluctuate by 5%.

BITMAIN TECHNOLOGIES INC.
www.bitmain.com

Documents / Resources

BITMAIN S19e XP Hyd Algorithm With Maximum Hashrate [pdf] Instruction Manual
S19e XP Hyd. 251T, S19e XP Hyd. 240T, S19e XP Hyd Algorithm With Maximum Hashrate, S19e XP Hyd, Algorithm With Maximum Hashrate, Maximum Hashrate

References

Leave a comment

Your email address will not be published. Required fields are marked *