BITMAIN S19e XP Hyd Algorithm With Maximum Hashrate
Product Information
Specifications
Product Glance | Value |
---|---|
Model | S19e XP Hyd. |
Sub Version | |
Crypto algorithm/coins | SHA256|BTC/BCH/BSV |
Typical hashrate, TH/s(1-1) | 251 |
Power on wall @35(1-2), Watt(1-1) | 240 |
Power efficiency on wall@35(1-2), J/T(1-1) | 10 |
Frequently Asked Questions (FAQ)
- Q: What is the recommended coolant for the S19e XP Hyd.?
A: The recommended coolants are Antifreeze, Pure water, or Deionized water based on the specified pH values.
Specification
Product Glance | Value | |
Model | S19e XP Hyd. | |
Sub | 251T | 240T |
Version | 10 | |
Crypto algorithm/coins | SHA256|BTC/BCH/BSV | |
Typical hash rate, TH/s(1-1) | 251 | 240 |
Power on wall @35℃(1-2), Watt(1-1) | 5522 | 5280 |
Power efficiency on wall@35℃(1-2), J/T(1-1) | 22 |
Detailed Characteristics
Detailed Characteristics | Value |
Power supply | |
Phase | 3 |
Input voltage, Volt(2-1) | 380~415 |
Input frequency range, Hz | 50~60 |
Input max current, Amp | 12 |
Hardware configuration | |
Network connection mode | RJ45 Ethernet 10/100M |
Server size (length*width*height, w/o package), mm | 410*170*209 |
Server size (length*width*height, with package), mm | 570*316*430 |
Net weight, kg | 12.8 |
Gross weight, kg | 14.1 |
Environment requirements | |
Inlet coolant temperature, °C | 20~50 |
Coolant flow, L/min | 8.0~10.0 |
Coolant pressure, bar | ≤3.5 |
Working Coolant (2-2) | Antifreeze/ Pure water/ Deionized water |
Coolant pH value | Antifreeze: 7.0~9.0 Prue water: 6.5~7.5
Deionized water:8.5~9.5 |
Diameter of Coolant pipe connector, mm | OD10 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Notes:
- The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by 3%, and the actual power on wall and power efficiency on wall fluctuate by 5%.
- Inlet coolant temperature.
- Caution: Wrong input voltage may cause server damaged.
- For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!
Performance Curve
- Hashrate vs. Inlet Coolant Temperature.
- Power Efficiency vs. Inlet Coolant Temperature.
- The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by 3%, and the actual power efficiency on wall fluctuate by 5%.
BITMAIN TECHNOLOGIES INC.