Insulation Loop RCD
100/250/500/1000V 2/20/200/2000Ω 10/30/100/300/500/1000mA
PSC PFC Earth
2000A/20kA 2000A/20kA 2000A/50kA 20/200/2000Ω
ACV Continuity Phase rotation
300/600V 20/200/2000Ω
Frequency SPD (Varistor) PAT

Communication interface

KYORITSU KEW 6516 Multifunction Installation Tester - partsKYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD.
www.kew-Itd.co.jp
Operation in 3 simple steps

KYORITSU KEW 6516 Multifunction Installation Tester - icon 1 Set the rotary dial to your testing range.
KYORITSU KEW 6516 Multifunction Installation Tester - icon 1 Connect the instrument to the installation under test.
KYORITSU KEW 6516 Multifunction Installation Tester - icon 1 Press the test button.
KYORITSU KEW 6516 Multifunction Installation Tester - parts1

Hands free testing

By remote probe or using the Lockdown function of the test button.
KYORITSU KEW 6516 Multifunction Installation Tester - parts2

Large LCD

All the test data is shown in one large colored screen.
KYORITSU KEW 6516 Multifunction Installation Tester - parts3KYORITSU KEW 6516 Multifunction Installation Tester - icon 2 Anti-Trip Technology (with 2 & 3 wire)
For no trip LOOP L-PE testing on all RCDs.
With 3wire (L, N, PE), to get the best accuracy readings.
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).

HELP Key

HELP function will show instrument according to how to connect the the function selected.
KYORITSU KEW 6516 Multifunction Installation Tester - parts40.001 resolution
Thanks to high test current of 25A, the Loop Impedance Phase to Earth is measured with high resolution of 0.001 ohm. This can be useful when testing in the main switchboard closer to the transformer.
KYORITSU KEW 6516 Multifunction Installation Tester - parts5KYORITSU KEW 6516 Multifunction Installation Tester - parts6Wide variety of RCDs can be tested
Type AC, A, F, B (General & Selective) EV and Variable
RCDs. Single and Auto test, Ramp test and Contact voltage.
KYORITSU KEW 6516 Multifunction Installation Tester - parts7PAT test
PAT test (PAT = Portable Appliance Tester) It is possible to check the insulation resistance and earth bond continuity of portable appliances for class I and II.
KYORITSU KEW 6516 Multifunction Installation Tester - parts8

Zs/Ra Limit

KYORITSU KEW 6516 Multifunction Installation Tester - parts9The verification of safety requirement on an electrical installation is simplified by using Zs/Ra Limit function.
This function will automatically check if the measured loop impedance for TN (or earth loop for TT) is low enough to trip (disconnect) the MCB / Fuse / RCD giving the result of PASS(v) or FAIL (x) on the display.
SPD test
SPD (Surge Protection Device) which contains varistor can be tested measuring the tripping voltage without damage it. KYORITSU KEW 6516 Multifunction Installation Tester - parts10Connectivity
KEW 6516 can download the test data by connecting the USB adapter (Model 8212-USB) and then print complete Test Reports by a PC.
While KEW 6516BT can transfer the test datatoa Tablet or Smartphone via Bluetooth. Such test data can be saved, shared and sent by email. The USB adapter can also be ordered as an option. KYORITSU KEW 6516 Multifunction Installation Tester - parts11KEW 6516 and KEW 6516BT come complete with everything you need for testing an electrical installation

Accessories

KYORITSU KEW 6516 Multifunction Installation Tester - parts12Optional Accessories

KYORITSU KEW 6516 Multifunction Installation Tester - parts13MODEL7272
2 cord reels with test leads,
2 spikes, an earth test lead,
a carrying case.KYORITSU KEW 6516 Multifunction Installation Tester - parts14MoDEL 8259
Adapter for measurement terminal terminal [red, yellow, green/1 se] KYORITSU KEW 6516 Multifunction Installation Tester - parts15MFT and EVSE ADAPTER Kits
KEW 6516-EV2: KEW 6516×1, KEW 8802×1
KEW 6516BT-EV2: KEW 6516BTx1, KEW 8602×1

KEW 6516 / 6516BT Specifications

Insulation resistance

Test voltage 100V 250V 500V 1000V Max.1000V
Measuring ranges 2.000/20.00/200.0MΩ
(Auto-ranging)
20.00/200.0/1000MΩ
(Auto-ranging)
20.00/200.0/2000MΩ
(Auto-ranging)
0-1000V(goes up by1V)
Accuracy ±2%rdg±6dgt (2.000/20.00MΩ)
±5%rdg±6dgt (200.0MΩ)
±2%rdg±6dgt (20.00/200.0MΩ)
±5%rdg±6dgt (1000MΩ)
±2%rdg±6dgt (20.00/200.0MΩ)
±5%rdg±6dgt (2000MΩ)
±5%rdg±5dgt
Rated current 1.0-1.2mA @0.1MΩ 1.0-1.2mA @0.25MΩ 1.0-1.2mA @0.5MΩ 1.0-1.2mA @1MΩ
Short circuit current 1.5mA max

Loop impedance

Function LOOP ATT LOOP HIGH
L-PE/L-N(3wire) L-PE(2wire) L-PE(0.01ΩRes) L-PE(0.001ΩRes) L-N/L-L
Rated voltage 100-260V(50/60Hz) 48-260V(50/60Hz) 48-260V(50/60Hz) 100-260V(50/60Hz) 48-500V(50/60Hz)
Impedance range 20.00/200.0/2000Ω
(Auto-ranging)
20.00/200.0/2000Ω
(Auto-ranging)
2.000Ω 20.00Ω
Accuracy ±3%rdg±6dgt ±3%rdg±10dgt ±3%rdg±4dgt ±3%rdg±25mΩ ±3%rdg±4dgt
Nominal test current at 0Ω external loop: Magnitude/Duration at 230V L-N:6A/60ms
N-E:10mA
L-PE:15mA 20Ω:6A/20ms
200Ω:0.5A/20ms
2000Ω:15mA/500ms
25A/20ms 6A/20ms

PSC/PFC

Range 2000A/20kA(L-N(PSC)/L-PE(PFC)) 2000A/20kA(PFC) 2000A/20kA(PFC) 2000A/50kA(PFC) 2000A/20kA(PSC)
Accuracy PSC/PFC accuracy is derived from measured loop impedance specification and measured voltage specification

RCD

Rated voltage 100-260V(50/60Hz)
Function x1/2, x1,x5,Ramp,Auto,Uc
6/10/30/100/300/500/1000mA/variable
RCD type AC(G/S) A(G/S) F(G/S) B(G/S) EV
Trip current setting x1/2,x1,Uc 10/30/100/300/500/1000mA(G)

10/30/100/300/500mA(S)

10/30/100/300/500mA 10/30/100/300/500mA 10/30/100/300mA 6mA(×1 only)
x5 10/30/100mA 10/30/100mA 10/30/100mA 10/30mA
Ramp 10/30/100/300/500mA 10/30/100/300/500mA 10/30/100/300/500mA 10/30/100/300mA 6mA
Accuracy Trip current x1/2 -8% – -2% -10% – 0% -10% – 0% -10% – 0%
x1 +2% – +8% 0% – +10% 0% – +10% 0% – +10% 0% – +10%
x5 +2% – +8% 0% – +10% 0% – +10% 0% – +10%
Ramp -4% – +4% -10% – +10% -10% – +10% -10% – +10% -10% – +10%
Trip time x1/2 2000ms(G/S):±1%rdg±2ms
x1 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms 10.5s:±1%±2ms
x5 410ms(G/S):±1%rdg±2ms

Continuity

Range 20.00/200.0/2000Ω (Auto-ranging)
Open circuit voltage (DC) 7-14V
Measuring current 200mA >200mA or more(2Ω or less)
15mA 15mA±3mA(short-circuit)
Accuracy ±2%rdg±8dgt

Phase Rotation

Rated voltage 48-600V(50/60Hz)
Remarks Remarks Correct phase sequence: are displayed “1.2.3” and mark Reversed phase sequence: are displayed “3.2.1” and mark

Volts

Range 300.0/600V(Auto-ranging)
Measuring ranges Volts 2-600V
Frequency 45-65Hz
Accuracy Volts ±2%rdg±4dgt
Frequency ±0.5%rdg±2dgt

Earth

Range 20.00/200.0/2000Ω(Auto-ranging)
Accuracy ±2%rdg±0.08Ω(20.00Ω)
±2%rdg±3dgt(200.0/2000Ω)

General

Applicable Standards IEC 61010-1 CAT Ⅳ 300V / CATⅢ 600V Pollution degree 2, IEC 61010-2-034, IEC 61557-1,2,3,4,5,6,7,10, IEC 60529(IP40), IEC 61326(EMC)
Communication Interface USB, Bluetooth® 5.0*¹, AndroidTM 5.0 or later, iOS 10.0 or later
Power source LR6(AA)(1.5V) × 8
Dimension 136(L) × 235(W) × 114(D)mm
Weight 1350g (including batteries)
Accessories Mains test lead*², 7281(Test leads with remote control switch), 7246(Distribution board test lead), 7228A(Earth resistance test leads), 8041(Auxiliary earth spikes[2 spikes/1 set])

9084(Soft case), 9142(Carrying case), 9151(Shoulder strap), 9199(Shoulder pad), LR6(AA) × 8, Instruction manual, 8212-USB(USB adapter with “KEW Report(Software)”)*³, Calibration certificate

Optional Accessories 8212-USB(USB adapter with”KEW Report(Software)”)*³, 8259(Adapter for measurement terminal), 7272(Precision measurement Cord set), 8017A(Extension prod long) 8601(EVSE ADAPTER), 8602(EVSE ADAPTER)

*¹ 6516BT only
*² 7187A:British plug, 7218A:(EU)European SCHUKO plug, 7221A(SA) South african plug, 7222A:(AU)Australian plug
*³ 8212-USB : Standard accessory for 6516, optional accessory for 6516BT
Bluetooth is a trademark or registered trademark of Bluetooth SIG. Inc. Android is a trademark or registered trademark of Google Inc.
iOS is a trademark or registered trademark of Cisco Technology, Inc. in the United States and other countries.

KYORITSU KEW 6516 Multifunction Installation Tester - icon 3 Safety Warnings :

Please read the “Safety Warnings” in the instruction manual supplied with the instrument thoroughly and completely for correct use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure to operate the instrument on a correct power supply and voltage rating marked on each instrument.
For inquires or orders :

logo
2-5-20, Nakane, Meguro-ku, Tokyo, 152-0031 Japan
Phone:+81-3-3723-0131
Fax:+81-3-3723-0152
KYORITSU KEW 6516 Multifunction Installation Tester - QR code
www.kew-lItd.co.jp
@This leaf et was produced n September 2023.
The contents of this eaflet are subject to change without notice
KEW 6516/65 16BT-3E Seo.23 SS

Documents / Resources

KYORITSU KEW 6516 Multifunction Installation Tester [pdf] Instruction Manual
KEW 6516 Multifunction Installation Tester, KEW 6516, Multifunction Installation Tester, Installation Tester, Tester

References

Leave a comment

Your email address will not be published. Required fields are marked *