អ្វីដែលអ្នកនឹងត្រូវការ៖
Before starting the setup process, ensure you have the following:

  • WaveLinx CORE device
  • កុំព្យូទ័រយួរដៃ
  • ខ្សែអ៊ីសឺរណិត
  • Standalone network switch (optional)

Setting Up WaveLinx CORE:

  1. WaveLinx CORE IP Address Assignment:
    1. Power on WaveLinx CORE and connect your laptop to it using an Ethernet cable.
    2. Set your laptop’s IP address to 192.168.2.nnn range with subnet mask 255.255.255.0.
    3. Access WaveLinx CORE through a web browser using the default IP address (https://192.168.2.100).
    4. Login as Admin with default password BXLinx!5 and follow the on-screen instructions to set up the IP address.
    5. Note down the WaveLinx CORE IP address for future reference.
  2. WaveLinx CORE LAN Setup:
    1. Disconnect the laptop from WaveLinx CORE and connect WaveLinx CORE to the LAN switch.
    2. Access WaveLinx CORE through a web browser using the recorded IP address.
    3. Log in as Admin and proceed with the setup wizard to configure Date and Time settings.

សុវត្ថិភាពសំខាន់

អាន និងធ្វើតាមការណែនាំសុវត្ថិភាពទាំងអស់។

  • Class 1 component installation should be performed by a qualified electrician.
  • Installation shall be by all applicable local and NEC codes.
  • Designed for indoor installation and use only
  • Turn the power off at the circuit breaker before wiring electrical components.
  • ខ្សែភ្លើងថ្មីទាំងអស់ត្រូវតែផ្ទៀងផ្ទាត់យ៉ាងពេញលេញ មុនពេលប្រើប្រាស់ថាមពល
  • Servicing of equipment should be performed by qualified service personnel
    WaveLinx CORE is an on-site Smart Spaces Platform that moves real-time monitoring and processing to the edge of the network. It makes collected data, such as light level and occupancy status, available to third-party systems through BACnet IP and the Published API.

អ្វីដែលអ្នកនឹងត្រូវការ

  • Chrome 87+ or MS Edge 88+ on your computer
  • A list of IP addresses for the WaveLinx CORE, WaveLinx Area Controllers (WAC), and/or WaveLinx Wired Ethernet Gateways (EG2)
  • Latest WaveLinx CORE and WAC firmware versions

Port Selection for WaveLinx CORE Enterprise
The Ethernet port noted below must be used for WaveLinx CORE Enterprise installations.

COOPER-WaveLinx-Area-Controller-fig-2

WaveLinx CORE IP Address Assignment

Connect WaveLinx CORE

  • Power the WaveLinx CORE.
  • Connect your laptop to the WaveLinx CORE using an Ethernet cable, directly or via a standalone network switch.
    ចំណាំ៖ The WACs/EG2s must be on the same LAN or subnets connected by the router.

Connect to Device Setup

  • Set the IP address of your laptop to a value in the 192.168.2.nnn range (e.g., 192.168.2.200) with a subnet mask of 255.255.255.0 and the default gateway blank.
  • ប្រើរបស់អ្នក។ Web browser to connect to the WaveLinx CORE IP address (https://192.168.2.100 by default).
  • Log in to the WaveLinx CORE as “Admin” (the default password is “BXLinx!5”). This will trigger a password change and require you to log in to WaveLinx CORE with the new password. The Wizard will be launched, but only the Network phase will be used at this point.

    COOPER-WaveLinx-Area-Controller-fig-3

  • Enter (Manual or DHCP) the IP Address, Subnet Mask, and Default Gateway values from the Site Administrator. NOTE: Record the WaveLinx CORE IP address for later. IP ADDRESS: __________________________________
  • OPTIONAL: If you are setting up dual network interfaces with CORE Enterprise, enter the separate IP Address, Subnet Mask, and Default Gateway values for the Corporate Network (typically Network Interface Card 2). IP ADDRESS: __________________________________
  • Click Next, then close the Web កម្មវិធីរុករក។

WaveLinx CORE LAN Setup

Connect WaveLinx CORE to the Network

  • Disconnect the Ethernet connection from your laptop to the WaveLinx CORE.
  • Connect the WaveLinx CORE to the LAN switch using an Ethernet cable.
  • Connect your laptop to the LAN.
    ចំណាំ: If you are using a static IP address on the LAN, please change your laptop’s IP address to one that can access WaveLinx CORE.
  • ប្រើរបស់អ្នក។ Web browser to connect to WaveLinx CORE at the IP address recorded earlier (STEP 2d: WaveLinx CORE IP Address Assignment).
  • Log in to WaveLinx CORE as “Admin” (using the new password).
  • When the Wizard starts, click Next, then click New System, to move on to the Date Time phase.

កំណត់កាលបរិច្ឆេទនិងពេលវេលា

  • Select the Time Zone in which WaveLinx CORE will be operating, and then select the desired Date Format.
  • Select NTP Synchronization, then enter the NTP Server address.
    សំខាន់៖ NTP Synchronization must be set up and enabled to obtain reliable data.

    COOPER-WaveLinx-Area-Controller-fig-4

  • Click Next, and then confirm the WaveLinx CORE reboot required to apply the Date Time changes.
  • Wait for WaveLinx CORE to reboot, then log in, and then proceed to the Organization page.
  • Enter the Organization name, then optionally set the Working Hours (under Additional Details), and then click Next to proceed to the Discover phase.

Discover Controllers

  • Click Automatic, and then click Discover Now.
  • Verify that all Controllers are discovered. If any are missing, ping each IP address (or telnet to port 8081) to test its network status.

    COOPER-WaveLinx-Area-Controller-fig-5

  • Once all connected Controllers are discovered, select the checkbox for each Controller you want to connect to WaveLinx CORE (10 at a time on larger sites is recommended).

    COOPER-WaveLinx-Area-Controller-fig-6

  • Repeat the Controller selection in Step c) until all Controllers have been imported.
  • Click Next to move to the Building phase, and then configure one or more buildings (use Add Building when setting up multiple Buildings).
    ចំណាំ៖ Be sure to set the time zone for each Building so that Schedules will function properly.
  • Click Next to move to the Floor phase, and then configure one or more floors (use Add Floor when setting up multiple Floors).
  • Click Next to move to the Area Controllers phase.

Set Up Area Controller

  • Under Please select a floor, choose the Building and Floor combination for the first Area Controller.

    COOPER-WaveLinx-Area-Controller-fig-7

  • Repeat Step a) for each Area Controller.
  • Click Finish to apply your configuration, and then log in to WaveLinx CORE when the system is available again.

Change Default Passwords

  • While logged in to the WaveLinx CORE as “Admin”, click (upper right), then click Admin, and then click Users.
    ចំណាំ៖ The “Admin” password was changed earlier, but if you decide to change it again, do so after the rest are complete to avoid being automatically logged out.
  • For each default account, click the Username, and then click Change Password in the User Details sidebar.
  • Enter and confirm a new, valid password, then optionally select Password Expires, and then click Save.

Verify Installation and Setup

Confirm that the WaveLinx CORE alarm and event monitoring are working. For example, disconnect one of the WaveLinx Area Controllers and check that an alarm is generated within 10 minutes.

ជំហានបន្ថែម

Refer to the WaveLinx CORE System Configuration Guide when performing any of the following optional tasks:

  • Set up BACnet by referring to “Setting Up BACnet”. Use a BACnet explorer, such as CAS BACnet Explorer from http://chipkin.com or BACnet Explorer NG from https://sierramonitor.com, to discover the WaveLinx CORE and its associated BACnet objects.
  • Set up the WaveLinx CORE Published APIs by referring to “Configuring the Published APIs”.
  • Set up the demand response interfaces by referring to “Configuring Demand Response”.
  • Review the applications of the Enterprise Dual Network Interface Card by referring to the following sections:
    • Enterprise Dual Network Interface Card Configuration (located in the Appendix)
    • Setting Up BACnet
    • Setting Up the Email Server

សេចក្តីថ្លែងការណ៍របស់ FCC

ឧបករណ៍នេះអនុលោមតាមផ្នែកទី 15 នៃច្បាប់ FCC ។ ប្រតិបត្តិការគឺស្ថិតក្រោមលក្ខខណ្ឌពីរដូចខាងក្រោមៈ

  1. ឧបករណ៍នេះប្រហែលជាមិនបង្កការរំខានដែលបង្កគ្រោះថ្នាក់ទេ។
  2. ឧបករណ៍នេះត្រូវតែទទួលយកការជ្រៀតជ្រែកណាមួយដែលទទួលបាន រួមទាំងការជ្រៀតជ្រែកដែលអាចបណ្តាលឱ្យប្រតិបត្តិការដែលមិនចង់បាន។

ចំណាំ៖ អ្នកផ្តល់ជំនួយមិនទទួលខុសត្រូវចំពោះការផ្លាស់ប្តូរ ឬការកែប្រែណាមួយដែលមិនត្រូវបានអនុម័តដោយភាគីដែលទទួលខុសត្រូវចំពោះការអនុលោមតាមច្បាប់នោះទេ។ ការកែប្រែបែបនេះអាចចាត់ទុកជាមោឃៈនូវសិទ្ធិអំណាចរបស់អ្នកប្រើប្រាស់ក្នុងការដំណើរការឧបករណ៍។
ចំណាំ៖ The equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy and, if not installed and used according to the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Suppose this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on. In that case, the user is encouraged to try to correct the interference by one or more of the following measures:

  • តំរង់ទិស ឬផ្លាស់ប្តូរទីតាំងអង់តែនទទួល។
  • បង្កើនការបំបែករវាងឧបករណ៍និងអ្នកទទួល។
  • ភ្ជាប់ឧបករណ៍ទៅនឹងព្រីនៅលើសៀគ្វីដែលខុសពីឧបករណ៍ទទួលត្រូវបានភ្ជាប់។
  • ពិគ្រោះជាមួយអ្នកចែកបៀ ឬអ្នកបច្ចេកទេសវិទ្យុ/ទូរទស្សន៍ដែលមានបទពិសោធន៍ ដើម្បីទទួលបានជំនួយ។

ឧបករណ៍នេះអនុលោមតាមដែនកំណត់នៃការប៉ះពាល់នឹងវិទ្យុសកម្ម FCC ដែលបានកំណត់សម្រាប់បរិស្ថានដែលមិនអាចគ្រប់គ្រងបាន។ ឧបករណ៍នេះត្រូវតែត្រូវបានដំឡើង និងដំណើរការដោយអនុលោមតាមការណែនាំដែលបានផ្តល់ ហើយអង់តែនដែលប្រើសម្រាប់ឧបករណ៍បញ្ជូននេះត្រូវតែត្រូវបានដំឡើង ដើម្បីផ្តល់ចម្ងាយដាច់ពីគ្នាយ៉ាងហោចណាស់ 20 សង់ទីម៉ែត្រពីមនុស្សទាំងអស់។

ការធានា និងដែនកំណត់នៃការទទួលខុសត្រូវ

សូមយោងទៅ www.cooperlighting.com/global/resources/legal សម្រាប់លក្ខខណ្ឌ និងលក្ខខណ្ឌរបស់យើង។

អំពីក្រុមហ៊ុន

សំណួរគេសួរញឹកញាប់

  • What should I do if I forget the password for WaveLinx CORE?
    If you forget the password, you can perform a password reset by following the instructions provided in the user manual or contacting customer support.
  • Can I use WaveLinx CORE without connecting it to a LAN?
    No, WaveLinx CORE requires connection to a LAN for proper functionality and data access.