KEMLAN Insert Series II Coupe Insert
IMPORTANT:
INSTALLER, PLEASE LEAVE THESE INSTRUCTIONS WITH THE UNIT ON COMPLETION.
10 YEAR FIREBOX WARRANTY
The firebox is covered by a 10 year warranty. Other parts are covered by a one year limited warranty.
- Head Office – 13 French Avenue, Brendale, Queensland 4500
- Telephone – PH: (07) 3490 5500
- Facsimile – FAX: (07) 3490 5520
- Website: – www.jetmaster.com.au
- Business hours: – Monday to Thursday 7:30 am-4:00 pm. Friday 7:30am-2:00pm Email: – sales@jetmaster.com.au
DIMENSIONS
TWO DOOR DOUBLE SIDED UNIT CENTRE FLUE SUIT BUILDING INTO MASONRY
A | B | C | D | E | F | G | |
MEASUREMENTS | 615 | 505 | 725 | 557 | 608 | 720 | 152 |
INSTALLATION INSTRUCTION
COUPE MASONRY CAVITY INSTALLATION
\INSTALLATION INSTRUCTION
FULL MASONRY CHIMNEY INSTALLATION
NB The opening on each side and top should allow for a gap (minimum 20mm) from fireplace body to allow for heat expansion. (i.e. for a gap of 20mm the opening would be 665 wide x 745 high )
INSTALLATION INSTRUCTION
Alternate finish to full masonry chimney
INSTALLATION INSTRUCTION
ROOM DIVIDE INSTALLATION
NB The opening on each side and top should allow for a gap (minimum 20mm) from fireplace body to allow for heat expansion.(i.e. for a gap of 20mm the opening would be 665 wide x 745 high )
COUPE MANTLE DIMENSIONS (minimum requirements)
INSTALLATION INSTRUCTIONS
MINIMUM HEIGHT OF FLUE SYSTEM EXIT INSTALLATION TO COMPLY WITH AS/NZS 2918
Operating Instructions
Whether you have purchased a small, medium or large chamber fireplace the set-up is the same. Kelman introduces more primary air into the chamber of the fireplace than most other brands on the market, this makes it very easy to light the fire from a cold start, it also makes it easy for you the user of the fireplace to load the paper or firelighters, kindling (small pieces of soft wood) and hard wood into the chamber straight away. Your goal should be to fill the fireplace chamber front to back, side to side to make sure heat is evenly distributed throughout the entire firebox. We don’t want to have to keep tending to the fireplace slowly adding pieces of timber and constantly opening the door, one full load of timber is far better Scan the QR code below to access the ‘How to stack and light your Kemlan wood fire’ video. Please take some time to watch to see if your process is the same.

When it is time to add timber to your fireplace firstly make sure the underside of your white baffles is actually white, if they are still black this will mean the hardwood has not fully caught alight. If this is the case wait, you will notice as the fire heats up and your seasoned hardwood is fully lit the baffle plates will return to there original white condition, this means the fire drawing correctly through the flue system and burning cleanly with the secondary air in full swing. You can now open the air slide fully, crack the door slightly allowing the air pressure to equal then carefully fully open the door. Have the timber you are going to load in the chamber ready to immediately reload, be prepared, don’t open the door and then go looking for the optimal pieces of timber, the longer you wait the colder the chamber will get and the higher the chance of smoke coming back into the room.
All medium and large-size Kemlan fireplaces have what is called an ‘overnight burn’ but what does this mean: As we have touched on above, the air slide should only be shut down fully when you want the extended length of burn, as soon as you starve the firebox of air the fire will burn dirtier and heat Dutput will be greatly reduced, in some instances the glass will blacken due to the lack of air movement inside the chamber. The black creosote will burn off the glass when the fire’s air control isback up to high with a new load of timber. Generally, a Kemlan medium to large chamber will burn between 8- 12 hours depending on the quality of fuel/timber and how full you stack the chamber. For maximum burn time you would hill the chamber up to 50mm below the secondary air tubes underneath the white baffle plate. The larger the pieces of timber the better! After the 8-12 hours you should still have glowing embers in the base of the fire, a small amount of kindling and medium size pieces of hardwood can then be re-loaded making sure the air control has been moved back to full left’ introducing maximum primary air again. f you follow these simple steps, you will find your Kemlan fireplace is one of the best investments you have made to your home. From everyone in Kemlan, we thank you for your business and wish you a lifetime of warmth and enjoyment.
IMPORTANT:
UNDER NO CIRCUMSTANCES SHOULD ANY SOLVENTS SUCH AS METHYLATED SPIRITS, PETROL, MINERAL TURPENTINE ETC OR DETERGENTS, BE ALLOWED TO COME IN CONTACT WITH THE PAINTED SURFACE OF THE HEATER AS DAMAGE TO THE FINISH WILL RESULT. IF AN ACCIDENT DOES OCCUR, SPRAY CAN PAINT IS AVAILABLE FROM YOUR NEAREST KEMLAN DEALER.
WARRANTY
- Kemlan wood heaters carry a warranty on the 6mm firebox for a period of ten (10) years.
- This warranty also covers other components of the heater for a period of one (1) year. These components include the baffle plate, handle assembly, secondary air tubes and fan.
- Kemlan’s warranty covers the wood heaters against defects in materials and manufacture.
THIS WARRANTY DOES NOT COVER
- Failure to comply with manufacturer’s operation instructions.
- Normal wear and tear or damage caused by incorrect installation.
- Any form of rust and/or corrosion to the painted finish of the heater.
- Damage to the glass in the door, if the damage is caused by impact or misuse.
- The cost of collection and delivery of the wood heater and/or parts.
- Damage caused by water ingress.
- Cost of removal of defective heater or re-installation of replacement heater.
- Failure to use fireplace components supplied by Kemlan Industries Pty Ltd.
- Cost of inspection for damaged heater.
CLAIMS
- Kemlan will provide a full replacement of the heater in the first five years after installation.
- (ii) Replacement in the subsequent five years (i.e. sixth to tenth year after installation will be on the following basis. Owner will pay fifty percent of the current retail price, if the claim is made in
- the sixth year – tenth year after purchase. Replacement of heater subject to all conditions in section four of warranty.
- Should any defects occur, contact the Kemlan distributor from whom you purchased the heater.
- Under this warranty the defective parts will be repaired or replaced, free of charge.
- The fireplace installation must comply with the relevant local statutes, ordinances, regulations and by-laws.
THIS WARRANTY IS VOID IF:
- The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals. Over-firing can be identified by, but not limited to, warped plated or tubes, rust coloured cast iron, bubbling, cracking and discolouration of steel or enamel finishes.
PLEASE COMPLETE AND RETAIN THIS SECTION FOR YOUR RECORDS
- Purchased from: ………………………………………………………………………………………….
- Address: …………………………………………………………………………………………………….
- Date of Purchase: …………………………………………………………………………………………
Documents / Resources
![]() |
KEMLAN Insert Series II Coupe Insert [pdf] Instruction Manual Insert Series II, Coupe Insert, Insert Series II Coupe Insert, Insert |