Schneider Electric TPRAN2X1 Input Output Modul Instruksi Manual
PETUNJUK KESELAMATAN
BAHAYA
BAHAYA KECUT ELEKTRIK, bledosan, utawa lampu kilat busur
- Waca lan mangerteni dokumen iki lan dokumen sing kadhaptar ing kaca 2 sadurunge nginstal, ngoperasikake, utawa njaga TeSys Active.
- Peralatan iki mung kudu dipasang lan dilayani dening tenaga listrik sing mumpuni.
- Pateni kabeh daya nyediakke peralatan iki sadurunge soyo tambah, kabel, utawa kabel piranti iki.
- Gunakake mung vol sing ditemtokaketage nalika ngoperasikake peralatan iki lan produk sing gegandhengan.
- Gunakake peralatan pelindung pribadi (PPE) sing cocog lan tindakake praktik kerja listrik sing aman miturut syarat peraturan lokal lan nasional.
Gagal ngetutake instruksi kasebut bakal nyebabake pati utawa ciloko serius.
WARNING
BAHAYA GEDUNG
Gunakake mung sawetara wiring gauge tartamtu karo peralatan lan tundhuk karo syarat mandap kabel kasebut.
Gagal ngetutake instruksi kasebut bisa nyebabake pati, ciloko serius, utawa karusakan peralatan.
WARNING
OPERASI PERALATAN sing ora dikarepake
- Aja mbongkar, ndandani, utawa ngowahi peralatan iki.
Ora ana bagean sing bisa dilayani pangguna. - Instal lan operate peralatan iki ing pager jumbuh rating kanggo lingkungan dimaksudaké.
- Tansah rute kabel komunikasi lan kabel daya kanthi kapisah.
- Kanggo instruksi lengkap babagan modul safety fungsional, waca Pandhuan Keamanan Fungsional,
8536IB1904
Gagal ngetutake instruksi kasebut bisa nyebabake pati, ciloko serius, utawa karusakan peralatan.
WARNING: Produk iki bisa nyedhiyakake sampeyan kanggo bahan kimia kalebu Antimony oxide (Antimony trioxide), sing dikenal ing Negara Bagian California nyebabake kanker. Kanggo informasi luwih lengkap menyang www.P65Warnings.ca.gov.
Dokumentasi
- 8536IB1901, Pandhuan Sistem
- 8536IB1902, Pandhuan Instalasi
- 8536IB1903, Pandhuan Operasi
- 8536IB1904, Pandhuan Safety Fungsional
Kasedhiya ing www.se.com.
Fitur
- A. Kabel flat
- B. Indikator status LED
- C. Konektor karo terminal spring
- D. kode QR
- E. jeneng tag
Pemasangan
mm: ing.
Kabel
|
![]() |
![]() |
![]() |
10 mm
0.40 ing. |
0.2–2.5 mm²
AWG 24–14 |
0.2–2.5 mm²
AWG 24–14 |
0.25–2.5 mm²
AWG 22–14 |
mm | ing. | mm2 | AWG |
Wiring
TPRDG4X2
Modul TeSys Active Digital I/O minangka aksesoris TeSys Active. Wis 4 input digital lan 2 output digital.
Sekring output: 0.5 Tipe T
Konektor |
Pin1 | Digital I/O |
Terminal |
![]() |
1 | Input 0 | I0 |
2 | Input 1 | I1 | |
3 | Input Umum | IC | |
4 | Input 2 | I2 | |
5 | Input 3 | I3 | |
6 | Hasil 0 | Q0 | |
7 | Output Umum | QC | |
8 | Hasil 1 | Q1 |
1 Jarak: 5.08 mm / 0.2 in.
TPRAN2X1
Modul TeSys Active Analog I/O minangka aksesoris TeSys Active. Wis 2 input analog configurable lan 1 output analog configurable.
Saiki / Voltage Input Piranti Analog
Konektor | Pin1 | Analog I / O | Terminal |
![]() |
1 | Input 0 + | I0 + |
2 | Input 0 − | I0− | |
3 | NC 0 | NC0 | |
4 | Input 1 + | I1 + | |
5 | Input 1 − | I1− | |
6 | NC 1 | NC1 | |
7 | Output + | Q+ | |
8 | Output − | Q− |
1 Jarak: 5.08 mm / 0.2 in.
Saiki / Voltage Output Piranti Analog
Termokopel
Resistance Temperature Detector (RTD)
Elinga
- Peralatan listrik kudu dipasang, dioperasikake, dilayani, lan dijaga mung dening personel sing mumpuni.
- Ora ana tanggung jawab sing ditindakake dening Schneider Electric kanggo akibat saka panggunaan materi iki.
Schneider Electric Industries SAS
35, rue Joseph Monier
CS30323
F - 92500 Rueil-Malmaison
www.se.com
Dicithak ing kertas daur ulang
Schneider Electric Limited Sajarah rega saham
Taman Stafford 5
Telford, TF3 3BL
Inggris
www.se.com/uk
MFR44099-03 © 2022 Schneider Electric Kabeh hak dilindhungi undhang-undhang
MFR4409903
Dokumen / Sumber Daya
![]() |
Schneider Electric TPRAN2X1 Input Modul Output [pdf] Instruksi Manual TPRDG4X2, TPRAN2X1, TPRAN2X1 Modul Input Output, Modul Input Output, Modul Output, Modul |