Specifications

Model FLS-50
Power Meter FPM-50A
Test Jumpers 1-3 depending on the test setup

POWER METER CALIBRATION STEPS

  1. Select the proper connector interface type that the application requires.
  2. Do not connect APC to Non-APC connectors at any point, as damage can occur to the interface of the unit, the connector of the optical cord or both.
  3. Turn the unit on and let it warm up for 15 minutes to stabilize to prevent any wavelength/reference drifting.
  4. Select dB if you want to measure loss or select dBm if you want to measure the output power of a transmitting device.
  5. Clean and inspect all Connectors, repeat if needed before plugging the selected test cord into the unit’s interface.
  6. When measuring output power of a transmitting source, verify the unit is in the “dBm” mode and plug in the opposite end of the test cord into the input of the transmitting device that you want to measure, and review your results on the power meters screen.
  7. When measuring system/link or insertion loss is being measured, verify the unit is in the dB mode.
  8. When using this power meter in combination with a light source to perform optical loss testing you will need to calibrate the units. Based on the application, you will need 1-3 test cords. “See diagrams on back of card” Connect between 1-3 cords to the units, if using 2 or more cords you will need and an adapter/coupler or bulkhead to connect the 2 test cords together in the middle. The power meter should be in the dB mode, press the dB key 1 time. If the power meter is still in the dBm mode, press the dB key 2 times.
  9. You have now synced/calibrated the units together to ensure test results are accurate, which they will not be without performing the calibration process.

Diagrams

JONARD-TOOLS-FLS55-Multi-mode-and-Single-mode-Fiber-Optic-Light-Source- (1)

Two Reference Cord Test Method 

JONARD-TOOLS-FLS55-Multi-mode-and-Single-mode-Fiber-Optic-Light-Source- (2)

Reference Cord Testing Methods

JONARD-TOOLS-FLS55-Multi-mode-and-Single-mode-Fiber-Optic-Light-Source- (3)

*Note for multimode testing, the use of a mandrel wrap ring is recommended to use for the test cable plugged into the optical light source.

FAQ

  • What is the purpose of warming up the unit?
    Warming up the unit for 15 minutes stabilizes it to prevent wavelength/reference drifting.
  • Why should APC not be connected to Non-APC connectors?
    Connecting APC to Non-APC connectors can cause damage to the unit’s interface or the optical cord.
  • How do I know if the unit is in the correct mode?
    For measuring output power, ensure the unit is in “dBm” mode. For measuring loss, ensure it is in “dB” mode.

Documents / Resources

JONARD TOOLS FLS-55 Multi-mode and Single-mode Fiber Optic Light Source [pdf] Instruction Manual
FLS-55 Multi-mode and Single-mode Fiber Optic Light Source, FLS-55, Multi-mode and Single-mode Fiber Optic Light Source, Single-mode Fiber Optic Light Source, Fiber Optic Light Source, Light Source

References

Leave a comment

Your email address will not be published. Required fields are marked *