IOLET SAFEST V1.1 Activity Sensor
Product Information
Specifications
- Manufacturer: UnitedHealth Group
- Model: SAFEST Activity Sensor V1.1
- Power Supply: 5VDC 2.4A 12W USB-C
- Compliance: FCC Part 15, UL 62368-1:2019, CSA C22.2#62368-1:2019
- Distance Requirement: Minimum 20cm (8 inches) between the device and the body
Product Usage Instructions
- Installation
- Ensure the SAFEST Activity Sensor V1.1 is powered by a 5VDC 2.4A 12W USB-C power supply.
- Mount the device securely on the wall before plugging in the USB power cable.
- Do not cover or block any openings on the device except for plugging in the USB-C cable.
- Operation
Once installed, the SAFEST Activity Sensor V1.1 will monitor activity in the patient’s home environment. - Maintenance
Regularly check that the device is not overheating by ensuring the openings are not blocked. Unplug the USB power cable before removing the device from the wall for any maintenance.
Frequently Asked Questions
Q: What power supply should be used with the SAFEST Activity Sensor V1.1?
A: The device must be powered by a 5VDC 2.4A 12W USB-C power supply to ensure proper function and avoid damage.
Q: How far should I keep the device from my body when plugged in?
A: It is recommended to maintain a minimum distance of 20cm (8 inches) between the device and your body to comply with safety regulations.
Q: What should I do if the device overheats?
A: If the device overheats, unplug it immediately and ensure that none of the openings are blocked to allow for proper cooling.
About This Document
This document contains instructions for a patient, family member, or other caregiver to correctly install and use the SAFEST Activity Sensor V1.1 in a patient’s home. Review this entire document before starting the installation process to ensure conformance to all listed standards and common safety practices. This document and SAFEST Activity Sensor V1.1 are the intellectual property of UnitedHealth Group with Patent Pending and copyright protection, all rights reserved. All hardware and software names used in this document are likely to be registered trademarks and must be treated accordingly.
Listings, Regulatory Compliance, Approvals and Certifications
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This device complies with the following safety standards:
- UL 62368-1:2019 Ed.3+R:22Oct2021
- CSA C22.2#62368-1:2019 Ed.3+U1
This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm (8 inches) between the radiator and your body.
SAFEST V1.1 FCC ID: 2BEKJ-SAFESTV1-1 Contains FCC ID: 2AC7Z-ESPWROOMDA
The purpose of the SAFEST Activity Sensor with associated products and alerts is to monitor activity. It is not intended to diagnose, mitigate, treat, cure, or prevent any disease. Patients and caregivers should always rely on licensed medical professionals in making all health decisions and should use the information provided by the SAFEST Activity Sensor with associated products and alerts only as a resource for that process.
WARNINGS
- The SAFEST Activity Sensor V1.1 must be powered by a 5VDC 2.4A 12W USB-C power supply and cable. Use of a power supply that has different ratings may result in improper function, damage to the device, or a fire.
- Do not plug the USB power cable into a power supply until the device is mounted on the wall, and unplug it before removing it from the wall. While there is no scientific evidence for risk of exposure from radar signals similar to those used in the SAFEST Activity Sensor V1.1, it is recommended by the FCC to come no closer than 8 inches (20cm) to the device for a prolonged period when plugged into power.
- Do not cover or block any of the openings on the SAFEST Activity Sensor V1.1 other than plugging in the single USB-C cable. The openings are designed to cool the device and blocking them may overheat the device and potentially cause a fire.
- The SAFEST Activity Sensor with associated products and alerts does not replace the usual care and communication among patients, caregivers, and healthcare providers.
Overview
The SAFEST Activity Sensor V1.1 is a 64Ghz radar device used to safely and securely track the movement of individuals in a home. It does not have a camera and has been designed to ensure the privacy of individuals in their homes. Activity data is evaluated by the device, summarized, encrypted, and then sent securely through a wireless connection to a monitoring application. This monitoring application may alert you or a caregiver of possible changes in your health.
- The SAFEST Activity Sensor is supplied fully assembled and configured by the Violet Manufacturing Department at Reliant Medical Group and has no internal user-serviceable parts. It should never be disassembled! Changes or modifications, including painting, will void the user’s authority to operate the equipment.
- In order to function properly, the SAFEST Activity Sensor requires an external 5VDC USB-C power supply, USB-C cable, and a Wi-Fi hotspot which are not part of the SAFEST Activity Sensor. The external 5VDC USB-C power supply and cable must be rated at exactly 2.4A (12W).
While this power supply, cable and Wi-Fi hotspot are not part of the SAFEST Activity Sensor, instructions for their installation and use are described in detail below.
Specifications
Specifications for SAFEST Activity Sensor V1.1
Maximal Dimensions: | 2 x 2.6 x 1.25 in. (50 x 66 x 32 mm) H x W x D |
Weight: | 0.09 lbs (40g) |
Environmental Temperature: | 0°C to +40°C (+32°F to +104°F) |
Environmental Relative Humidity: | 0 – 90% non-condensing |
Power Input: | 5.0VDC nominal (4.75VDC minimum to 5.5VDC maximum) 2.4A (12W) USB-C power supply and cable |
Typical Current: | 2.2A @ 5VDC |
Maximum Current: | 2.4A @ 5.5VDC |
Minimum Mounting Height: | 6 feet (1.83m) from the bottom edge of the SAFEST Activity Sensor to the floor |
Maximum Mounting Height: | 7 feet (2.13m) from the bottom edge of the SAFEST Activity Sensor to the floor |
Installation
Location of the SAFEST Activity Sensor
The SAFEST Activity Sensor should be located in a dry indoor location protected from dripping water, close to an unswitched 120VAC power source, and in a position that is near the center of a wall in the room that it is monitoring. If the room is rectangular, try to locate the sensor on one of the shorter walls. Remember that it will be mounted on the wall 6 to 7 feet off the ground, so it can’t be on a window, picture, or doorway. Ideally, it should have an unobstructed view of people walking for distances as far as 30 feet from the sensor within the room, so don’t put it behind a decorative tree!
Location of the Cellular Wi-Fi Hotspot
The Cellular Wi-Fi Hotspot should be located on an outside wall, preferably near a window, and preferably within 50 feet of the SAFEST Activity Sensor. If you have been told which side of your house has the strongest cellular signal, use that side of the house. Referring to the manufacturer’s instructions, place the cellular antenna on the window sill (if possible) and the Wi-Fi antenna along the wall as close to the SAFEST Activity Sensor as possible. Then plug the Cellular Wi-Fi Hotspot into an unswitched 120VAC power outlet.
Connecting the USB-C Cable to the SAFEST Activity Sensor
- First, ensure that the USB-C cable is not plugged into a power source! Also, ensure that the cable is long enough to reach from your power source to where the SAFEST Activity Sensor will hang 6 to 7 feet up on the wall. The cable should hang straight down to the power supply, or hang straight down to the floor and then run along the wall until it reaches the power supply. Do not have the cable run diagonally along the wall because it could pull the sensor off the wall.
- Also, do not have the cable running into an area of the floor where people walk because someone could trip over the cable!
- Notice that there are 2 holes on the bottom of the SAFEST Activity Sensor. The center hole is for ventilation and should be left unobstructed. Plug the USB-C cable into the other hole on the bottom of the SAFEST Activity Sensor:
Mounting the SAFEST Activity Sensor onto the Wall
Use a tape measure to see if your fingertips can reach at least 6.5 feet above the ground where you will mount the SAFEST Activity Sensor. If not, get a secure step stool or ladder. If you are not safe climbing a step stool or ladder, get assistance! Hold the SAFEST Activity sensor up against the wall where you plan to mount it 6 to 7 feet above the ground with the USB-C cable dangling downward so that you are comfortable with the location and your ability to reach it. Use a dry clean cloth or paper towel to clean the wall in that location. You can use rubbing alcohol to help clean the area but do not use water or household cleaners.
When you are confident in the location, its cleanliness, and your ability to reach it, peel off the 2 adhesive backing strips:
Now, with the sticky side of the strips exposed and facing the wall, and the USB-C cable hanging down, make sure that it is approximately level. Then firmly push the SAFEST Activity Sensor against the wall in the desired mounting location and continue to apply pressure for 30 seconds. Then let go and the SAFEST Activity Sensor should continue to be stuck to the wall.
After it is stuck to the wall, do not try to remove or move it because it could rip the paint off of your wall! Instead, if you have to remove the sensor, follow the instructions at www.command.com/3M/en_US/command/how-to-use/picture-hanging-strips/#removal
Connecting the USB-C Cable to your Power Supply
Again confirm that your power supply or adapter is rated at 5VDC 2.4A as shown in Figure 2 above. Then plug your USB cable into the power supply or adapter and plug the power supply or adapter into an unswitched 120VAC power outlet. The SAFEST Activity Sensor will automatically turn on, start identifying activity, and start securely sending summary data to the monitoring application.
Operation
The SAFEST Activity Sensor works silently and automatically alerts the monitoring application if there are any potential problems with your activity or problems with the sensor itself. If a sensor problem is identified, you may be contacted and asked to look at the SAFEST Activity Sensor and report on any red, green, or blue colors that might be lighting up:
Maintenance
The SAFEST Activity Sensor requires no maintenance, but the occasional gentle removal of dust from the top with a dry feather-like duster is acceptable. Never use a wet duster!
Violet Manufacturing Department
- Reliant Medical Group 100 Front Street Worcester, MA 01605
- (508)852-0600
- www.ReliantMedicalGroup.org/Violet.