FLEXIBLE RANGE INDOOR DETECTOR
INSTALLATION INSTRUCTIONS
STANDARD
MODELS
Wide/Narrow area Flip lens |
PIR | |
IR-D-P1 | √ | √ |
Before installation
– Manufacturer’s statement
Symbol | Meaning |
![]() |
Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury. |
![]() |
Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage. |
Symbol | Meaning |
![]() |
Check mark indicates recommendation. |
![]() |
Nix sign indicates prohibition. |
NOTE | Special attention is required to the section of this symbol. |
Warning
Caution
– Parts identifications
Installation
1-1. Disassemble
- Unlock the cover
- Open the cover
- Remove the main unit
1-2. Wall mount without bracket
- Wire through the base
- Mount the base
1-3. Wall mount with bracket
- Wire and mount on the wall
NOTE :See page 4 for how to break the knockouts.
- Join the base on the bracket
NOTE: Adjust the detection direction while jointing.
Confirming with a walk test is required.
–> Refer to “3-1. Walk test” - Fix the base with the fixing screws (optional)
NOTE 2 fixing screws are required for the Grade 2 and higher grade installation.
1-4. Ceiling mount with bracket
How to change the bracket to the ceiling mounting
- Loosen the fixing screw.
- Rotate the body.
- Tighten the fixing screw.
- Wire and mount on the ceiling
NOTE See page 4 for how to break the knockouts.
- Join the base on the bracket
- Fix the base with the fixing screws (optional)
NOTE 2 fixing screws are required for the Grade 2 and higher grade installation.
1-5. Assemble and connect
- Attach the main unit to the base
- Connect wires to the terminal
Power cable length
The power cable should be limited to the following length.
IR-D-P1WIRE GAUGE 12 V DC 14 V DC AWG 22
(0.33 mm²)520 m
(1,710 ft.)1,130 m
(3, 718 ft.)AWG 20
(0.52 mm²)820 m
(2,690 ft.)1,790 m
(5,870 ft.)AWG 18
(0.83 mm²)1,320 m
(4,330 ft.)2,850 m
(9,350 ft.)
Settings
2-1. Wide/Narrow setting
NOTE Install the lens so that the letters on the cover and on the lens match your intention.
How to remove the lens
Caution
Be careful not to damage the light path of the LED.
Also, be careful not to allow the light path to pinch the wiring when closing the cover.
Caution
Be careful not to damage the lens with a screwdriver.
How to install the lens
Push the lens firmly at 3 points in numerical order.
Set the jumper pin to “Wide” or “Narrow”
Caution
- The jumper pin must be “Narrow”, when the lens is set to “Narrow”.
NOTE - Default setting is “Wide”.
- When “Narrow” is selected, MW detection will be disabled.
2-2. Jumper pin settings
Checking
3-1. Walk test
- Confirm that the LED pin is “ON” , then close the cover.
- Walk in the detection area to check the detecting performance via LED indication.
- Return the LED pin to “OFF” after the walk test, if necessary.
Lock the cover
NOTE Conduct a walk test at least once a year.
Other
– Specifications
Model | IR-D-P1 | |
Installation | ||
Detection method | Passive infrared | |
Coverage | Wide:12 m (40 ft.) 85°/ Narrow:18 m (60 ft.) 5° ( No MW detection at “Narrow” setting ) |
|
Detection zones | Wide: 76 zones/ Narrow: 12 zones | |
Mounting height | 2.0 to 3.0 m (6’7″ to 9’8”) | |
Alarm period | 2.0 ± 0.5 s | |
Warm-up period | Approx. 60 s (LED blinks) | |
LED indicator | Switchable ON/OFF Green: [1] Warm-up [2] Alarm | |
Electrical | ||
Power input | 9.5 to 16 V DC UL * | |
Current draw | 8 mA (normal) 11 mA (max.) at 12 V DC |
|
Relay output | Alarm | N.C. 24 V DC 0.1 A max. (Resistive load) |
Tamper | N.C. 24 V DC 0.1 A max. (Resistive load) (Open when the cover is removed.) |
|
Remote LED | ||
Environmental | ||
Operation temperature | -20℃ to +50℃(-4°F to +122°F) | |
Temperature compensation | Digital (SMDA) | |
Environmental humidity | 95% max. | |
RF interference | No alarm 10 V/m | |
Mechanical | ||
Dimension | H: 129.2 x W: 61.5 x D: 50.9 mm (H: 5.09” x W: 2.42” x D: 2.00”) | |
Weight | Approx. 90 g (3.17 oz) (with Bracket : Approx. 120 g (4.23 oz)) |
|
Mounting | Wall, Corner (Indoor) (with Bracket : Wall, Corner, Ceiling) |
- Specifications and designs are subject to change without prior notice.
- These units are designed to detect an intruder and activate an alarm control panel.
Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
UL * Shall be powered via a UL listed burglar alarm class 2 output power limited power supply that has a min standby power of 4 hrs.
– Dimensions
– Detection area
NOTE
- The * 2.4 m dotted line indicates the recommended mounting height.
- Narrow area settings are not certified to the following standards.
EN 50131-2-2 (IR-D-P1)
– Angle adjustment with bracket IR-D-CW-G2
– Compliance
EN 50131-1 Grades and Environmental Class; Security Grade 2, Environmental Class II
Applied Standards; EN 50131-2-2 (IR-D-P1)
Tested and certified by Kiwa
PD6662:2017v
Global Headquarters Inner Range Australia 1 Millennium Court, Knoxfield, Victoria, 3180, Australia Inner Range Middle East Plot No S20141, PO Box 16854 Jebel Ali Free Zone – South, Dubai, UAE IR INSTALL MANUAL: 63PIR-OS-IM 202310-31 |
Inner Range United States 2301 Patriot Blvd Glenview, IL 60026 Inner Range Canada 200 Foster Crescent Mississauga, Ontario, Canada L5R-3Y5 |
INNERRANGE.COM Inner Range United Kingdom Units 10-11 Theal Lakes Business Park Moulden Way, Reading, Berkshire RG74GB Inner Range India National Sales Office 95 Brigade Road, Bangalore, 560 025 India Copyright (C) 2023 Inner Range Pty Ltd. |
Documents / Resources
![]() |
Inner range IR-D-P1 Flexible Range Indoor Detector [pdf] Instruction Manual IR-D-P1, IR-D-CW-G2, IR-D-P1 Flexible Range Indoor Detector, IR-D-P1, Flexible Range Indoor Detector, Range Indoor Detector, Indoor Detector, Detector |