infinity series logoinfinity panic
Waterproof Panic Button for ESL, ESX, EC-i & infinity outputinfinity series EC-i Waterproof Panic Button -

Specifications

Operation 1 Programmable Button
Wireless Range Up t o  500m Line of Sight
Frequency SI6MHz
Modulation Type GFSK
Protocol infinity 2 Way Encrypted
Indication Haptic & LED Feedback
Battery Type 1x CR2032 Lithium (non replaceable)
Battery Life Up t o  5 Years
Operating Temperature -20°C t o  60°C
Environment Humidity 100% max
Dimensions 48mm x 44mm x 17mm
Ingress Protection P67
Functions Programmable Arm, Disarm, Panic, Output Control & Delayed Press Options

Overview

Function
Automatically pairs to ‘infinity link’ or ‘infinity output’ during learn procedure.
Optional ‘Delayed Press’ Function to help prevent false pressing. See bottom of page for more information:

2 Way Feedback
Panic button will vibrate & displayagreen LEDto, indicate a successful control panel or infinity Output operation.

infinity series EC-i Waterproof Panic Button - fig 1

Accessories

ClipinBase
With screw holes for wall mount or covert applications. infinity series EC-i Waterproof Panic Button - fig 2

Nylon Necklace
For medical & other emergency applications. infinity series EC-i Waterproof Panic Button - fig 3

Wrist Option
Locations For watch strap.
(Strap not included.
Requires 18mm x 1.5mm ‘single pass’ Strap).infinity series EC-i Waterproof Panic Button - fig 4

Default Programming
If the ‘infinity panic’ has been previously learnt into a system it will require defaulting before being learnt or re-learnt into a control panel or infinity output.

  1. To default: Press & hold the button for 10 seconds ( until the LED turns SOLID RED).
  2. As soon as the LED is SOLID RED, release the button, then press the same button 5 times in quick succession. (The LED will Fast flash orange during this part of the process).
  3. A GREEN LED will flash momentarily to confirm that the default has completed successfully.

infinity series EC-i Waterproof Panic Button - fig 5

Button Delay Options
The infinity panic can be programmed for ‘Instant Press’, ‘O.2sec Delay’ or ‘O.5sec Delay’ as detailed below:
Warning: Changing the function will not work if the remote is communicating with a control panel or ‘infinity output’. Make sure the remote is defaulted OR temporarily disconnect the ‘infinity link’ before proceeding.

  1. To change the button delay time: Press & hold the button For 5 seconds ( u n t i l the LED rapidly flashes RED).
  2. Assoon as the LED is rapidly flashing RED, release the button, then press the same button 5 times in quick succession. (The LED will fast flash orange during this part of the process).
  3. A GREEN LED will flash momentarily t o confirm that the default has completed successfully.
    The moment that the function has changed the infinity panic will vibrate to indicate the new function as detailed below:
    infinity series EC-i Waterproof Panic Button - icon 1 Vibration = 0.2sec Delay infinity series EC-i Waterproof Panic Button - icon1 2 Vibrations = O.5sec Delay infinity series EC-i Waterproof Panic Button - icon2 3 Vibrations = Instant Press

Learning into the ESL Contro! Panel (consult contro! panel installation manual for advanced programming)
ESL control panels have pre configured user slots to simplify the learning of wireless buttons/users.
These are located from users 4O to 89 as shown in ‘Pre-Configured ser Slots’ table below:

  • Make sure you are in installer programming mode (default PROG OOO000 ENTER) before continuing.
  • Press PROG 18 ENTER followed by the User Number you wish to learn, then ENTER. Next press
    ENTER again to start the Reypad beeps, indicating that the system is waiting to learn a remote button.
  • Press the remote button you wish to learn and the Reypad should stop beeping, indicating a successful learn.
  • To learn another button, press the right or left arrows on the Reypad to go to next or previous user slot, then press ENTER, or press PROG then ENTER to exit installer programming.
    Pre-Configured User Slots Table ( for ESL Series only)

infinity series EC-i Waterproof Panic Button - fig 6

Arm
Users 40 – 49
Users 40 to 49 will ARM only
Example: P18 E4OEE (learn beeps start) Press the remote button you wish to  learn (learn beeps stop)
This button will now ARM the system
Disarm
Users 50 – 59
Users 50 to 59 will DISARM only
Example: P18 E5QOEE (learn beeps start )  Press the remote button you wish to learn ( learn  beeps stop)
This button will now DISARM the system
Output 3
Users 60- 69
Users 60 to 69 will operate OUTPUT 3 & DISARM at the same time
Example: P18 E6QEE (learn beeps start )  Press the remote button you wish to  learn (learn beeps stop)
This button will now DISARM the system & control output 3 at the same time
Output 4
Users 70- 79
Users 70 to 79 will operate OUTPUT 4 & DISARM at the same time
Example: P18E 70OEE (learn beeps start )  Press the remote button you wish to  learn (learn beeps stop)
This button will now DISARM the system & control output 4 at the same time
Panic
Users 80- 789
Users 80 to 89 will operate as a PANIC button
Example: P18 E8OEE (learn beeps start )  Press the remote button you wish to learn ( learn  beeps stop)
This button will now perform a PANIC function

infinity series EC-i Waterproof Panic Button - fig 7

Battery Low Reporting & Haptic Feedback

  • P7Emust be set t o option | (Freelink) to enable battery low reporting & For the remote t o operate correctly.
  • Haptic feedback is disabled when battery is low is reported due t o the remote entering power save mode.
  • Battery low will be indicated at 2.2V & under

infinity series logoManufactured by Arrowhead Alarm Products Ltd – www.aap.co.nz