CLT20-Ex 4 Simple Steps
“
Specifications:
- Manufacturer: Intermodal Telematics BV
- Model: CLT20-Ex
- Serial Number: YYYY/IM20CLTXXXXX
- Designation: EPT 20 ATEX 3744X IECEX EUT 20.0007X
- Equipment Category: 2 (Zone 1 areas)
- Ex Marking: Ex Electrical apparatus with explosion protection
acc. EN-IEC standards - Type of Protection: Intrinsic Safety (ib)
- Gas Group: IIC
- Temperature Class: T4
Product Usage Instructions:
1. Installation
1.1 General:
The CLT20-Ex is a Communications and Location Terminal designed
for industrial applications. It includes a battery powered
GSM/HSPA/LTE Cat M1/NB1 modem and GPS receiver. The battery is
factory mounted and not user-replaceable.
1.2 Installation:
The device is intended for fixed installations only. Adhere to
local regulations and IEC60079-14 standards for electrical
installations in explosive atmospheres.
1.3 Electrostatic Discharge:
The CLT20-Ex has a non-metallic surface that minimizes
electrostatic charge build-up. Clean the device using a damp cloth
to prevent potential hazards.
2. Inspection, Maintenance, and Repair
2.1 Inspection and Maintenance:
Follow the requirements specified in EN-IEC 60079-17 or relevant
local codes of practice. Regularly inspect the device for any
damage or deterioration. If the enclosure is damaged, remove it
from the hazardous area for repair.
2.2 Repair:
If the device enclosure is cracked, broken, or in poor
condition, it must be repaired immediately before further use. Only
return the device to operation after repairs have been completed
and approved.
FAQ:
Q: Can the battery in the CLT20-Ex be replaced by the
user?
A: No, the battery is factory mounted and should not be replaced
by the user.
Q: How often should maintenance be performed on the
CLT20-Ex?
A: The maintenance cycle depends on specific usage conditions.
For light use, it is recommended to perform maintenance at least
once every 12 months.
“`
1 SUMMARY OF ATEX AND IECEX MARKINGS
Intermodal Telematics BV
· · Korte Huifakkerstraat 8 4815 PS Breda The Netherlands CLT20-Ex
SERIAL NUMBER YYYY/IM20CLTXXXXX
AAAAA
EPT 20 ATEX 3744X IECEX EUT 20.0007X
0344
II 2 GD
Ex ib IIC T4 Gb Ex ib IIIC T135ºC Db Ta: -40º C … +60º C
WARNING: Potential electrostatic charging hazard – see instructions – Clean only using a wet cloth
YYYY is the year of production. XXXXX is the serial number. AAAAA is the device code.
DESIGNATION ACCORDING TO DIRECTIVE 2014/34/EU:
Notified body performing the QA surveillance Equipment Group II (Surface Industries)
2 Equipment Category 2 (Equipment with a high level of protection suitable for in Zone 1 areas)
GD For explosive mixtures of gasses, mists, vapors or dust in air
Ex marking:
Ex Electrical apparatus with explosion protection acc. EN-IEC standards
ib Type of protection (Intrinsic Safety)
IIC Gas group T4 Temperature class
Gb IEC equipment protection level
Ex marking:
Ex Electrical apparatus with explosion protection acc. EN-IEC standards ib Type of protection (Intrinsic Safety)
IIIC Dust group T135ºC Temperature class Db IEC equipment protection level
··EU-Type Examination Certificate Number with X marking: Warning: Potential Electrostatic Charging Hazard Clean only using a damp cloth European Standards applied for explosion protection:
International Standards applied for explosion protection:
Ambient temperature:
ATEX EPT 20 ATEX 3744X IECEx EUT 20.0007X
EN IEC 60079-0:2018 EN60079-11:2012 IEC 60079-0:2017 IEC 60079-11:2011 -40ºC < Ta < +60ºC
FCC ID: 2BG2S-CLT20EX1
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
2 INSTALLATION
2.1 GENERAL
The CLT20-Ex is a Communications and Location Terminal consisting of a battery powered GSM/HSPA/LTE Cat M1/NB1 modem and GPS receiver with proprietary communication for industrial applications. The battery is factory mounted and may not be replaced by the user.
2.2 INSTALLATION
The CLT20-Ex is only intended for fixed installations. Always follow local regulations and IEC60079-14 (Explosive atmospheres – Part 14: Electrical installations design, selection and erection) or other local codes of practice.
2.2.1 ELECTROSTATIC DISCHARGE
The CLT20-Ex has a non-metallic surface that exceeds 10.000mm2. Extensive testing has proven this to be safe when there is no risk of electrostatic charge build-up during the intended use. The following warning needs to be observed:
Warning: Potential Electrostatic Charging Hazard – Clean only using a damp cloth.
2.3 ELECTRICAL CONNECTION
There are no electrical connections to be made by the user.
3 INSPECTION, MAINTENANCE AND REPAIR
3.1 INSPECTION AND MAINTENANCE
The requirements as stated in EN-IEC 60079-17 or other codes of practice valid at the place of installation apply.
If the CLT20-Ex enclosure appears cracked, dented, broken, very dirty or otherwise no longer in good condition, it must be repaired or cleaned immediately.
As the devices internal circuits are always on, in case of damage it must be removed from the hazardous area immediately and may only be restored after the repair has been carried out and approved.
Cycle of maintenance depends on the specific conditions of use. As a general guideline for light use a 12 month interval is recommended.
3.2 REPAIR
Repair to the CLT20-Ex may only be done using original parts. It shall be carried out by qualified skilled workers who have been trained in accordance with EN-IEC 60079-19 or other codes of practice valid at the place of installation. Repairing with non original parts may lead to personal injury and/or damage to the equipment.
If non-original parts are used, or repair has been carried out in an incompetent manner, the warranties concerning explosion safety no longer apply. Therefore it is advised to return the equipment to the manufacturer in cases where a repair is required.
3.3 SPECIAL CONDITIONS FOR SAFE USE
Warning: Potential Electrostatic Charging Hazard – Clean only using a damp cloth. See section 2 Electrostatic discharge
Intermodal Telematics BV
Korte Huifakkerstraat 8
· · Tel.: +31 (0)76 231 02 00
4815 PS Breda
The Netherlands
info@intermodaltelematics.com
· · Version CLT20Ex-18.06.2024 Specifications are subject to change without notice
www.intermodaltelematics.com
Telematics Taking Over
intermodaltelematics.com
CLT20-Ex Installation manual 4 simple steps
Version 1.2
READ BEFORE INSTALLING
INSTALLATION PROCEDURE ON TANK CONTAINER (CORNER)
1
CHECK
Check if an IMT L-bracket is fitted to the tank container.
2
WELD
Weld the bracket in the top left triangle at the back of the tank container.
3
ATTACH
Attach the CLT20-Ex using self- locking nuts.
4
SCAN
Scan the QR CODE on the CLT20-Ex and follow the instructions to register the unit.
MAKE SURE AN UNOBSTRUCTED EXPOSURE OF THE SOLAR PANEL TO THE SUN.
www.intermodaltelematics.com
INSTALLATION PROCEDURE ON TANK CONTAINER (WALKWAY)
1
CHECK
Check if an IMT L-bracket is fitted to the tank container.
2
ATTACH
Attach the bracket to the walkway with bolts and self-locking nuts or use a thread-lock. Utilise all three holes in the L-bracket.
3
ATTACH
Attach the CLT20-Ex using self- locking nuts.
4
SCAN
Scan the QR CODE on the CLT20-Ex and follow the instructions to register the unit.
MAKE SURE AN UNOBSTRUCTED EXPOSURE OF THE SOLAR PANEL TO THE SUN.
Any questions: support@intermodaltelematics.com
INSTALLATION PROCEDURE ON RAIL WAGON
1
CHECK
Check if an IMT bracket is fitted to the wagon.
2
DRILL
Drill holes to the wagon according to the drawing.
3
RIVET
Rivet the CLT20-Ex in place with the defined rivets. Pay attention to the correct rivet length for the wagon wall thickness.
4
SCAN
Scan the QR CODE on the CLT20-Ex and follow the instructions to register the unit.
MAKE SURE AN UNOBSTRUCTED EXPOSURE OF THE SOLAR PANEL TO THE SUN.
www.intermodaltelematics.com
Documents / Resources
![]() |
IMT CLT20-Ex 4 Simple Steps [pdf] Instruction Manual 2BG2S-CLT20EX1, 2BG2SCLT20EX1, CLT20-Ex 4 Simple Steps, CLT20-Ex, 4 Simple Steps, Simple Steps |