Product Usage Instructions

  1. Charge the receiver to at least 50%.
  2. Download the desired firmware. It could include multiple updates for mainboard OEM and Radio. Connect to the receiver once for each update.
  3. Connect to the receiver via Wi-Fi:
    • Click on the network icon in the system tray and select the
      device with the GNSS-serial_number of your receiver.
    • No password is required for i83.
  4. Open a browser window and navigate to 192.168.1.1. Log in with Username ‘admin’ and Password ‘password’ (lower case).
  5. Check the current firmware version under Firmware info.
  6. To update firmware:
    • Main Board: Click on ‘Firmware Update’ and then ‘Browse’.
    • OEM Board: Click on ‘GNSS Board Upgrade’ and then ‘Browse’.
  7. Select the correct downloaded firmware file and click Confirm.
  8. The update process will take around 2 minutes. The receiver window will display ‘Updating…’ during the process and ‘Update Success’ at the end. The receiver will reboot after the update.
  9. If multiple updates are required, repeat the process starting from step 3.

NTRIP Caster on CHC or iGage Receiver
Date: 8 October 2021

Thesis
The CHC and most iGage receivers have an internal NTRIP caster that can be used to send Base corrections to drone controllers or other devices. Once you setup the caster, it will stay setup until a complete factory reset is performed. So, this is a once and done configuration.

These receivers have an NTRIP caster:  iG5, iG8, iG8a, iG9, iG9a i73, i80, i90, i83, i89, i93, iBASE

NOTE: the iGage iG10 has a different method which is described in this FAQ: [ iG10 NTRIP Caster ]

Setup

Connect to the receiver using the Wi-Fi interface

  1. Connect to the receiver by Wi-Fi: Click on the network icon in tool tray (1), then expand the list of available connections (2):iGage-i83-Sic-Marking-FIG- (1)
  2. Click on the device with GNSS-serial_number of your receiver.iGage-i83-Sic-Marking-FIG- (2)
  3. Click on Connect.iGage-i83-Sic-Marking-FIG- (3)If you are asked for a Wi-Fi password, try “12345678”.
  4. Open an incognito browser window and navigate to the address 192.168.1.1:iGage-i83-Sic-Marking-FIG- (4)The default ‘Login Account’ is ‘admin’ and the Password is ‘password’ (lower case). Click Login.
  5. The receiver status screen will be displayed:iGage-i83-Sic-Marking-FIG- (5)
  6. Click on I/O Settings:iGage-i83-Sic-Marking-FIG- 17
  7. Click on the Connect button for the first TCP Server… line, usually line 8:iGage-i83-Sic-Marking-FIG- (7)
  8. The TCP Server/NTRIP Caster dialog is shown:iGage-i83-Sic-Marking-FIG- (8)Configure: 
    • Auto connection Checked (TRUE)
    • Connection Protocol NTRIP
    • User Name user
    • Password user Port 2101
    • Mount Point RTCM32
    • Differential Data: RTCM3.2
    • Click on Confirm.
  9. The port will now display as ‘opened’:
    Configuration is complete and will remain available/active until you change it or do a factory reset on the receiver.iGage-i83-Sic-Marking-FIG- (9)

Configure the Receiver as a Base

Setup the head as a Base using Carlson SurvCE/SurvPC, X-PAD, Field Genius, LandStar or via the Web interface directly (shown below).

To configure from the web interface
Login to the receiver as shown above.

Click on Receiver Configuration, then Reference Station Settings:

iGage-i83-Sic-Marking-FIG- (10)

Set Reference Station Mode = Manual Base. Click oniGage-i83-Sic-Marking-FIG- (11)

iGage-i83-Sic-Marking-FIG- (12)

The receiver’s autonomous position will be loaded, click Save to start Base operation at the entered coordinate.

Configuration
I like to use the LaFebure NTRIP Client to test the connection. This is the configuration for the receiver setup above:

iGage-i83-Sic-Marking-FIG- (13)

Click OK.
Change the NTRIP Stream to Download Source Table

iGage-i83-Sic-Marking-FIG- (14)

Then click Connect.

Drop the NTRIP Stream:

iGage-i83-Sic-Marking-FIG- (15)

and select RTCM32.

Click Connect:

iGage-i83-Sic-Marking-FIG- (16)

Correction data will begin streaming. Congratulations, any device that connects to the head will have access to the correction stream.

iGage Mapping Corporation

FAQ

Q: Do I need a password to connect to the i83 receiver via Wi-Fi?
A: No, no password is required for connecting to the i83 receiver via Wi-Fi.

Documents / Resources

iGage i83 Sic Marking [pdf] Instructions
i83, i89, i93, iBase, iG8, iG9, i83 Sic Marking, i83, Sic Marking, Marking

References

Leave a comment

Your email address will not be published. Required fields are marked *