Danfoss-LOGO

Danfoss POV 600 Compressor Overflow Valve

Danfoss-POV-600-Compressor-Overflow-Valve-product

Nkọwapụta

  • Ụdị: Compressor overflow valve POV
  • Onye nrụpụta: Danfoss
  • Nrụgide Range: Up to 40 barg (580 psig)
  • Igwe nju oyi Applicable: HCFC, HFC, R717 (Ammonia), R744 (CO2)

Ntuziaka ojiji ngwaahịa

Nwụnye

  1. The POV valve is used in conjunction with the BSV back-pressure independent safety relief valve to protect compressors against excessive pressure.
  2. Install the valve with the spring housing upwards to avoid thermal and dynamic stress.
  3. Ensure the valve is protected from pressure transients like liquid hammer in the system.
  4. The valve should be installed with the flow towards the valve cone as indicated by the arrow on the valve.

ịgbado ọkụ

  1. Remove the top before welding to prevent damage to O-rings and teflon gaskets.
  2. Use materials and welding methods compatible with the valve housing material.
  3. Clean internally to remove welding debris before reassembly.
  4. Protect the valve from dirt and debris during welding.

Mgbakọ

  1. Wepu irighiri ihe ịgbado ọkụ na unyi sitere na ọkpọkọ na ozu valvụ tupu mgbakọ.
  2. Tighten the top with a torque wrench to the specified values.
  3. Ensure grease on bolts is intact before reassembling.

Agba na njirimara

  • Precise identification of the valve is made via the ID label on the top and stampna-abanye na valvụ ahụ.
  • Prevent external surface corrosion with a suitable protective coating after installation.

Nwụnye

  • Mara! Valve-type POV is categorised as a compressor overflow accessory (not as a safety accessory).
  • Hence, a safety valve (e.g. SFV) has to be installed to protect the system against excessive pressure.

$Refrigerants

  • Ọdabara na HCFC, HFC, R717 (Amonia) na R744 (CO2).
  • A naghị atụ aro hydrocarbon na-enwu ọkụ. A na-akwado valvụ ahụ naanị maka iji na sekit mechiri emechi. Maka ozi ndị ọzọ, biko kpọtụrụ Danfoss.

Oke okpomọkụ

  • POV: -50/+150 Celsius (-58/+ 302 °F)

Oke nrụgide

  • The valves are designed for a maximum. working pressure of 40 barg (580 psig).

Nwụnye

  • The POV valve is used in conjunction with the BSV back-pressure independent safety relief valve and is specifically designed for protecting compressors against excessive pressure (fig. 5).Danfoss-POV-600-Compressor-Overflow-Valve-fig-5
  • See the technical leaflet for further installation instructions.
  • The valve should be installed with the spring housing upwards (fig. 1).Danfoss-POV-600-Compressor-Overflow-Valve-fig-1
  • By mounting the valve, it is important to avoid the influence of thermal and dynamic stress (vibrations).
  • Emebere valvụ ahụ iji gbochie nrụgide dị n'ime. Otú ọ dị, ekwesịrị ịmepụta usoro ọkpọkọ iji zere ọnyà mmiri mmiri ma belata ihe ize ndụ nke nrụgide hydraulic site na mgbasawanye ọkụ.
  • A ghaghị ijide n'aka na valvụ ahụ na-echebe site na nrụgide nrụgide dị ka "hama mmiri" na usoro.

Ntuziaka mgbaba akwadoro

  • The valve should be installed with the flow towards the valve cone as indicated by the arrow on the figure. 2.Danfoss-POV-600-Compressor-Overflow-Valve-fig-2
  • A naghị anabata ọsọ n'akụkụ nke ọzọ.

ịgbado ọkụ

  • The top should be removed before welding (fig. 3) to prevent damage to the O-rings between the valve body and top, as well as the teflon gasket in the valve seat.Danfoss-POV-600-Compressor-Overflow-Valve-fig-3
  • Do not use high-speed tools for dismantling and reassembling.
  • Be sure that the grease on bolts is intact before reassembling.
  • Only materials and welding methods compatible with the valve housing material must be applied.
  • Ekwesịrị ịsacha valvụ ahụ n'ime ime iji wepụ ihe mkpofu ịgbado ọkụ mgbe emechara ịgbado ọkụ yana tupu agbakọta valvụ ahụ.
  • Zere irighiri ihe na ịgbado ọkụ na eriri nke ụlọ na n'elu.

Enwere ike ịhapụ iwepụ elu ahụ ma ọ bụrụ na:

  • The temperature in the area between the valve body and top, as well as in the area between the seat and the teflon cone during welding, does not exceed +150 °C/+302 °F.
  • This temperature depends on the welding method as well as on any cooling of the valve body during the welding itself (cooling can be ensured by, for example, wrapping a wet cloth around the valve body).
  • Make sure that no dirt, welding debris, etc, gets into the valve during the welding procedure.
  • Kpachara anya ka ị ghara imebi mgbanaka cone teflon.
  • Ụlọ valvụ ahụ aghaghị ịbụ nke na-enweghị nchekasị (ibu dị n'èzí) mgbe echichi gasịrị.

Mgbakọ

  • Wepu irighiri ihe ịgbado ọkụ na unyi ọ bụla sitere na ọkpọkọ na ahụ valvụ tupu mgbakọ.

Na-agbatị

  • Tighten the top with a torque wrench to the values indicated in the table (fig. 4).Danfoss-POV-600-Compressor-Overflow-Valve-fig-4
  • Do not use high-speed tools for dismantling and reassembling. Be sure that the grease on bolts is intact before reassembling.

Agba na njirimara

  • A na-eme nchọpụta nke ọma nke valvụ ahụ site na akara ID dị n'elu, yana site na Stampna-abanye na valvụ ahụ.
  • A ghaghị ichebe elu dị n'èzí nke ụlọ valvụ ahụ pụọ na corrosion na mkpuchi nchebe kwesịrị ekwesị mgbe echichi na mgbakọ.
  • Nchedo nke akara ID mgbe ị na-ese valvụ ka akwadoro.
  • N'ọnọdụ obi abụọ, biko kpọtụrụ Danfoss.
  • Danfoss anaghị anabata ọrụ ọ bụla maka mmejọ na mmejọ. Ụlọ ọrụ Danfoss Industrial
  • Refrigeration nwere ikike ime mgbanwe na ngwaahịa na nkọwapụta na-enweghị ọkwa mbụ.

Ndị ọrụ nlekọta ndị ahịa

  • Danfoss A / S
  • Ngwọta ihu igwe
  • danfoss.com
  • +4574882222
  • Any information, including, but not limited to, information on selection of the product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals catalogues, descriptions, advertisements, etc, and whether made available in writing, orally, electronically, online or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation.
  • Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material
  • Danfoss nwere ikike ịgbanwe ngwaahịa ya na-enweghị ọkwa.
  • This also applies to products ordered but not delivered, provided that such alterations can be made without changes to the form, fit or function of the product.
  • Ighalaahia niile dị n'ihe a bụ ihe onwunwe nke ụlọ ọrụ Danfoss A/S ma ọ bụ Danfoss Group. Danfoss na akara Danfoss bụ ụghalaahịa nke Danfoss A/S. Ikike niile echekwabara.
  • © Danfoss
  • Ngwọta ihu igwe
  • 2022.06

FAQ

  • Q: What refrigerants can be used with the POV valve?
    • A: The valve is suitable for HCFC, HFC, R717 (Ammonia), and R744 (CO2). Flammable hydrocarbons are not recommended.
  • Q: What is the maximum working pressure for the valves?
    • A: The valves are designed for a maximum working pressure of 40 barg (580 psig).

Akwụkwọ / akụrụngwa

Danfoss POV 600 Compressor Overflow Valve [pdf] Ntuziaka nwụnye
POV 600, POV 1050, POV 2150, POV 600 Compressor Overflow Valve, POV 600, Compressor Overflow Valve, Overflow Valve

Ntụaka