This user manual provides essential information for the safe and effective operation of your SMART SENSOR AS8909 Portable H2 Gas Detector. This device is designed for accurately detecting hydrogen gas (H2) concentrations in various environments, ensuring safety by alerting users to potentially hazardous levels.
Please read this manual thoroughly before using the device and keep it for future reference.
2. Ozi nchekwa
ỊDỌ AKA NA NTỊ: Ọ bụrụ na ịgbaso ntuziaka nchekwa ndị a nwere ike ibute nnukwu mmerụ ahụ ma ọ bụ ọnwụ.
- Jiri ngwaọrụ ahụ rụọ ọrụ mgbe niile dịka ntuziaka dị na akwụkwọ ntuziaka a si dị.
- Do not attempt to modify or repair the device. Refer all servicing to qualified personnel.
- Ensure the device is regularly calibrated to maintain accuracy. Inaccurate readings can lead to dangerous situations.
- This device is designed to detect hydrogen gas. It may not detect other hazardous gases.
- The device is certified with GB3836 series anti-explosion standard, ensuring its safe operation in potentially explosive atmospheres. However, always exercise extreme caution in such environments.
- Keep the device away from strong electromagnetic fields, extreme temperatures, and corrosive substances.
3. Ngwaahịa gafereview
The SMART SENSOR AS8909 is a compact and portable hydrogen gas detector featuring a high-sensitivity electrochemical sensor and a clear LCD display.
3.1. Ngwa ngwaọrụ

Foto 3.1: N'ihu view of the AS8909 H2 Gas Detector.

Figure 3.2: Labeled diagram showing key components including the high sensitive sensor, sampling pump connecting port, high density LCD screen with backlight, down button, up button, sound alarm, light alarm, confirm button, power on/off button, and battery charging port.
- High Sensitive Sensor: Located at the top, responsible for detecting H2 gas.
- Sampling Pump Connecting Port: For attaching an external sampling pump if needed.
- High Density LCD Screen: Displays H2 concentration, battery status, and other information. Features a backlight for visibility in dark conditions.
- bọtịnụ njikwa: Includes Up, Down, Confirm, and Power On/Off buttons for navigation and settings adjustment.
- Ihe ngosi mkpu: Integrated sound alarm, light alarm, and vibration alarm to alert users to gas presence.
- Port Ịchaji batrị: Located at the bottom for recharging the built-in Li-battery.
3.2. Nha na Mbugharị

Figure 3.3: The AS8909 detector measures approximately 120.2mm (height) x 64.5mm (width) x 38.3mm (depth), making it compact and easy to carry.

Figure 3.4: The compact design and unique clip allow for convenient portability, fitting comfortably in hand.
3.3. Alarm Features

Figure 3.5: The device features three distinct alarm types: audible (sound alarm), visual (light alarm), and tactile (vibration alarm). It differentiates between low and high alarm values with varying frequencies of alarming noise.
3.4. Atụmatụ igodo

Ọgụgụ 3.6: Zuru ezu views of the soft, comfortable buttons, the imported electrochemical sensor for accurate detection, the integrated rechargeable Li-battery, and the large, clear LCD screen.
3.5. Ndepụta nkwakọ ngwaahịa

Figure 3.7: The standard package includes the H2 gas monitor, user manual, charging adaptor, USB cable, hand carry case, calibration certificate, CNEX certificate, and a gift paper box.
3.6. Product Unboxing Video
Video 3.1: This video demonstrates the unboxing and contents of the AS8909 H2 Gas Detector package, showing the device and its accessories.
4. Nhazi
4.1. Nchaji mbụ
- Connect the provided USB cable to the charging adaptor.
- Plug the charging adaptor into a standard power outlet.
- Connect the USB cable to the battery charging port at the bottom of the detector.
- Allow the device to charge fully before first use. The battery indicator on the LCD screen will show charging status. A full charge typically provides 10-12 hours of continuous operation.
4.2. Powering On for the First Time
- Press and hold the Power On/Off button until the LCD screen illuminates.
- The device will perform a self-test and warm-up sequence. During this time, avoid exposing it to gas.
- Once the self-test is complete, the display will show '0 PPM' or the current ambient H2 concentration, indicating it is ready for use.
5. Ntuziaka ọrụ
5.1. Gbanyụọ / gbanyụọ
- Iji gbanye: Press and hold the Power On/Off button for approximately 3 seconds until the screen lights up.
- Iji gbanyụọ: Press and hold the Power On/Off button for approximately 3 seconds. The screen will display a countdown or a power-off message before shutting down.
5.2. Ịme nha
- Once powered on and warmed up, the device continuously monitors the H2 gas concentration in its immediate environment.
- The real-time H2 concentration (in PPM) is displayed prominently on the LCD screen.
- For specific areas, hold the detector steadily in the desired location. If using a sampling pump, ensure it is correctly attached and functioning.
5.3. Alarm Settings and Response
The AS8909 features adjustable high and low alarm values. Factory preset low alarm value is 50ppm, and high alarm value is 100ppm.
- Adjusting Alarm Values: Refer to the detailed instructions in the full user manual (provided in the package) for navigating the menu using the Up, Down, and Confirm buttons to set custom alarm thresholds.
- Mgbalite mkpu: When the detected H2 concentration reaches or exceeds the preset low or high alarm values, the device will activate its alarms: audible sound (up to 80dB), flashing light, and vibration.
- Na-aza Mkpu: If an alarm sounds, immediately take appropriate safety measures, such as evacuating the area, ventilating the space, and identifying the source of the gas leak. Do not re-enter the area until the H2 concentration has returned to safe levels.
6. Nlekọta
6.1. Nhicha
- Jiri nwayọ hichaa mpụta nke ngwaọrụ ahụ, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
- Ensure no liquid enters the sensor opening or charging port.
6.2. Nlekọta batrị
- Recharge the battery when the low battery indicator appears on the LCD screen.
- Zere ịgbasa batrị kpamkpam ugboro ugboro, n'ihi na nke a nwere ike ibelata ndụ ya.
- If storing the device for an extended period, charge the battery to approximately 50% and recharge every 3-6 months to prevent deep discharge.
6.3. nhazi nhazi
Regular calibration is crucial for maintaining the accuracy and reliability of your gas detector. It is recommended to have the device calibrated by a qualified professional at least once a year, or more frequently depending on usage and environmental conditions. Refer to the calibration certificate included in your package for details.
7. Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Ngwaọrụ anaghị agbanwu ọkụ. | Batrị dị ala ma ọ bụ mebie. | Jiri chaja enyere ya chajie ngwaọrụ ahụ nke ọma. |
| Inaccurate or fluctuating readings. | Sensor contamination or damage; device needs calibration. | Clean the sensor area carefully. Contact professional service for calibration or repair. |
| Alarm does not sound/light/vibrate. | Alarm settings are off; speaker/LED/vibrator malfunction. | Check alarm settings in the menu. If problem persists, contact support. |
| Ngwaọrụ jụrụ oyi ma ọ bụ ọ naghị anabata ya. | Nsogbu ngwanrọ. | Perform a soft reset by holding the power button until it shuts down, then restart. If unresponsive, allow battery to drain completely then recharge. |
Ọ bụrụ na ị na-ezute okwu anaghị edepụta ebe a ma ọ bụ ọ bụrụ na ngwọta akwadoro akwụsịghị nsogbu ahụ, biko kpọtụrụ nkwado ndị ahịa.
8. Nkọwapụta
| Njirimara | Nkọwapụta |
|---|---|
| Ụdị | Ihe mmetụta uche |
| Nlereanya | AS8909 |
| Ụdị gas | Hydrogen gas (H2) |
| Gas Measurement Range | 0 ~ 1000ppm |
| Mkpebi | 1pm |
| Ụkpụrụ ọrụ | Ihe mmetụta electrochemical |
| Typedị Oti mkpu | Sound, Light, Vibration (adjustable values) |
| Ọkwa ụda mkpu | Ruo 80dB |
| Okpomọkụ na-arụ ọrụ | -10 ~ 50 Celsius |
| Iru mmiri na-arụ ọrụ | 15~95%RH (standard) |
| Okpomọkụ nchekwa | 0 ~ 40 Celsius |
| Isi Iyi Ike | 3.7V rechargeable Li-battery (Built-in) |
| Arụ ọrụ ugbu a | 160mA |
| Obere sekit ugbu a | <3A |
| Ọkwa nchekwa | IP65 |
| Outer Enclosure Material | ABS plastik |
| Arọ Net Ngwaahịa | 200g |
| Akụkụ | 120.2 x 64.5 x 38.3mm |
| UPC | 785197913837 |
9. Akwụkwọ ikike na nkwado
Your SMART SENSOR AS8909 Portable H2 Gas Detector comes with a standard manufacturer's warranty. Please refer to the warranty card included in your product package for specific terms and conditions, including the warranty period and coverage details.
For technical support, troubleshooting assistance, or warranty claims, please contact SMART SENSOR customer service. Contact information can typically be found on the product packaging, the official SMART SENSOR website, or the included warranty card.
It is recommended to register your product online (if applicable) to facilitate warranty service and receive important product updates.