Specifications

General

  • Acceptance Rate 96% or greater
  • Note: The incomplete bills such as extremely dirty, wet, broken or wrinkled ones are excluded.
  • Bill Insertion
  • Transaction
  • Speed Interface
  • Four-way acceptance
  • Approx. 3 seconds to stack
  • Pulse, ICT
  • Protocol,
  • MOB,
  • GPT Parallel

Electrical

  • Power Source
  • Power Consumption
  • Operation Environment
  • 12V DC (11.4~12.6V DC)
  • 24V AC (21.6~26.4V AC)
  • 34V DC (20V~42.5V DC)
  • 12V DC- Standby: 0.41A, 5W Operation: 2A, 24W Maximum: 3A, 36W
  • Operation Temperature: 0° C~55° C Storage Temperature: -30° C~ 70° C Humidity: 30%~85RH

Mechanical

  • Outline Dimension
  • Bill Capacity
  • Weight
  • Refer to page.4
  • Approx. 400 bills (350-450)
  • Approx. 1.25kg

Packing List

  • Main
  • Accessory
  • Bill Acceptor
  • Harnesses: Refer to 5-1 BS? Installation Guide
  • BS? DIP Switch Setting Guide

DimensioniCT-BS7-Bill-Acceptor-Recycler-FIG-1

Installation

Harness Application

Power & *Data Comm. WEL-RV701 6
Standard 12VDC Extension Wire CU-R961-1 7
Pulse  

24VAC

Power & *Data Comm.

Extension Wire

WEL-RV703

WEL-RV702

 

9

MOB 34VDC Power & *Data Comm. WEL-RM006 10
Power WEL-RV701 6
ICT Protocol (RS232)  

12VDC

Extension Wire CU-R961-1

WEL-RV706-1

7
*Data Comm. or 11
2-BA-RV706
GPT Parallel 24VAC Power & *Data Comm. *5*R  BG-AA203L 1-XX 12

Data Comm.: Data Communication.
RBG-AA203L 1-xx: Plug-in Box & Cables, “XX” varies from version to version.iCT-BS7-Bill-Acceptor-Recycler-FIG-2iCT-BS7-Bill-Acceptor-Recycler-FIG-3iCT-BS7-Bill-Acceptor-Recycler-FIG-4iCT-BS7-Bill-Acceptor-Recycler-FIG-5iCT-BS7-Bill-Acceptor-Recycler-FIG-6iCT-BS7-Bill-Acceptor-Recycler-FIG-7

Circuit

Pulse InterfaceiCT-BS7-Bill-Acceptor-Recycler-FIG-9

ICT-Protocol Interface. iCT-BS7-Bill-Acceptor-Recycler-FIG-10

MDB Interface iCT-BS7-Bill-Acceptor-Recycler-FIG-11

GPT Parallel Interface iCT-BS7-Bill-Acceptor-Recycler-FIG-12

DIP Switch Setting 

There are two serial DIP switches which are located on the side of BS? (as FIG.01 ). According to different currencies which are used by users, DIP switch settings could be varied to fit users’ need. Besides, there’s also a serial DIP switches on CPU board inside of BS? for interface settings.(as FIG.02) Please refer to “BS? DIP Switch Setting” Guide in the package for more detail.iCT-BS7-Bill-Acceptor-Recycler-FIG-13

Software Download and Upgrade 

To download and upgrade the software to BS?, the programmer (FP-004) is needed. Please contact ICT to purchase FP-004 and refer to FP-004 user guide for software download and upgrade  information. iCT-BS7-Bill-Acceptor-Recycler-FIG-14

Maintenance

To make sure the bill acceptor always works smoothly, please clean the internal parts regularly.
To clean the internal parts:

  1.  Press the buttons on the sides of bill path unit and pull the unit out.iCT-BS7-Bill-Acceptor-Recycler-FIG-15
  2.  Use a soft, dry cloth or towel to clean the bill path and sensors.iCT-BS7-Bill-Acceptor-Recycler-FIG-16

Troubleshooting

Back LED Errors iCT-BS7-Bill-Acceptor-Recycler-FIG-17

iCT-BS7-Bill-Acceptor-Recycler-FIG-18

Documents / Resources

iCT BS7 Bill Acceptor Recycler [pdf] Installation Guide
BS7, Bill Acceptor Recycler
iCT BS7 Bill Acceptor [pdf] Installation Guide
BS7 Bill Acceptor, BS7, Bill Acceptor, Acceptor

References

Leave a comment

Your email address will not be published. Required fields are marked *