PMC-5151 Quick Start
Supported Models
- PMC-5151
Technical Support
- PMC-5151 User Manual and Firmware:
• http://pmms.icpdas.com/en/download.html
• ftp://ftp.icpdas.com/pub/cd/pmc_cd/pmc-5151/ - PMC-5151 Official Website:
• http://pmms.icpdas.com/en/PMC_5151.html
What’s in the box?
The package includes the following items:
PMC-5151 microSD card Screw Driver
Pin Terminal* 16
1 Configuring the Boot Mode
Before starting PMC-5151 at the first time, be sure that the switch is placed in the “0” position.
The rotary switch must be placed in the “0” position
2 Connect to PC, Network and Power
The PMC-5151 is equipped with an RJ-45 Ethernet port for connection to an Ethernet hub/switch and PC. You can also link directly the PMC-5151 to PC with an Ethernet cable.
3 Using Browser to Assign a New IP
The PMC-5151 is an Ethernet controller, which comes with a default IP setting; therefore, you must first assign a new IP setting to the LAN1 port of PMC. The factory default IP settings of PMC are as follows:
Item |
Default |
IP Address | 192.168.255.1 |
Subnet mask | 255.255.0.0 |
Gateway | 192.168.0.1 |
DNS Server | 8.8.8.8 (Default: Google DNS Server) |
Follow the following steps for PMC-5151 new IP setting:
Step1: Change the PC’s IP setting as following.
- IP: 192.168.255.10
- Subnet mask: 255.255.0.0
- Gateway address: 192.168.0.1
Step2: Make sure the PC and PMC(LAN1) is connecting through Ethernet.
Step3: Open a PC side browser, and type in the URL address (http://192.168.255.1) of the PMC to connect the Web Server in PMC.
Step4: Use default Administrator password “Admin” to login the system.
Step5: Please follow the sequence【System Setting】→【Network Setting】→【Network Setting(LAN1)】to change the IP setting of PMC.
Step6: After complete the IP setting, please save it, and then the new IP setting will take effect.
4 Go to PMC-5151 Web Site for Power Management
Please follow the steps below to build a power monitoring and management applications with ICP DAS PMC-5151 & Power Meter.
Step 1: Open a browser, and type in the URL address of the PMC
Open a browser and type in the URL address(The new IP setting) of the PMC in the address bar. Make sure the IP address is accurate.
Step 2: Get on the PMC web site
Get on the PMC web site. Complete the PMC setting in the order: 【Login】→【System Setting】→【Meter / Module Setting】→【Rule Setting】→【Save】for a power monitoring and management application.
Step 3: For more detail information, please refer to PMC-5151 User Manual
ventas@logicbus.com iTu sitio de automatizacion! + 52 (33)-3823-4349 www.tienda.logicbus.com.mx
Documents / Resources
![]() |
ICP DAS PMC-5151 Power Meter Concentrator [pdf] User Guide PMC-5151, Power Meter Concentrator |