ICON-logo

ICON Procon TVF-450 Flow Batching Controller

ICON-Procon-TVF-450-Flow-Batching-Controller-product

Quick Start Manual

ICON-Procon-TVF-450-Flow-Batching-Controller- (1)

Read the user’s manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice.

Symbol Explanation

ICON-Procon-TVF-450-Flow-Batching-Controller- (2)This symbol denotes especially important guidelines concerning the installation and operation of the device. Not complying with the guidelines denoted by this symbol may cause an accident, damage or equipment destruction.

Basic Requirements | User Safety

  • Do not use the unit in areas threatened with excessive shocks, vibrations, dust, humidity, corrosive gasses and oils.
  • Do not use the unit in areas where there is risk of explosions.
  • Do not use the unit in areas with significant temperature variations, exposure to condensation or ice.
  • The manufacturer is not responsible for any damages caused by inappropriate installation, not maintaining the proper environmental conditions and using the unit contrary to its assignment.
  • If in the case of a unit malfunction there is a risk of a serious threat to the safety of people or property additional, independent systems and solutions to prevent such a threat must be used.
  • The unit uses dangerous voltage that can cause a lethal accident. The unit must be switched off and disconnected from the power supply prior to starting installation of troubleshooting (in the case of malfunction).
  • Do not attempt to disassemble, repair or modify the unit yourself. The unit has no user serviceable parts.
  • Defective units must be disconnected and submitted for repairs at an authorized service center.

Specifications

General
Display LED | 6 Digit | 13mm High | Red
Displayed Values 0 ~ 999999
RS485 Transmission 1200…115200 bit/s, 8N1 / 8N2 | RS485
Housing Material NORYL
Protection Class NEMA 4X | IP65
Input Signal | Supply
Standard Current: 4-20mA | 0-20mA | 0-5V* | 0-10V*
Voltage 85 – 260V AC/DC | 16 – 35V AC, 19 – 50V DC*
Output Signal | Supply
Standard 2 x Relays (1A) | 4-20mA + 1 x Relay (1A)
Communication RS485
Voltage 24VDC
Passive current output * 4-20mA | (Operating Range Max. 2.8 – 24mA)
Performance
Accuracy ±0.1% @ 25°C One Digit
Temperatures
Operating Temperature -4 – 122°F | -20 – 50°C

Front Panel Description

ICON-Procon-TVF-450-Flow-Batching-Controller- (3)

Function of Push Buttons

ICON-Procon-TVF-450-Flow-Batching-Controller- (4)

Dimensions

ICON-Procon-TVF-450-Flow-Batching-Controller- (9)

Wiring Diagram
* Depending on Version 85/230/260V AC/DC ; 50 – 60 Hz 19/24 – 50V DC ; 16/24/35V AC

ICON-Procon-TVF-450-Flow-Batching-Controller- (10)

Wire Connection

  • Loosen Set Screw
  • Insert Wire
  • Tighten Set Screw ICON-Procon-TVF-450-Flow-Batching-Controller- (11)
  • Due to possible significant interference in industrial installations, appropriate measures assuring correct operation of the unit must be applied.
  • The unit is not equipped with an internal fuse or power supply circuit breaker.
  • For this reason, an external time-delay cut-out fuse with a small nominal current value must be used (recommended bipolar, max. 2A) and a power supply circuit breaker located near the unit.

Power Supply & Relay Connection

ICON-Procon-TVF-450-Flow-Batching-Controller- (12)

Note:
Contacts of relay outputs are not equipped with spark suppressors. When using the relay outputs for switching of inductive loads (coils, contactors, power relays, electromagnets, motors etc.) it is required to use additional suppression circuit (typically capacitor 47nF/ min. 250VAC in series with 100R/5W resistor), connected in parallel to relay terminals or (better) directly on the load.

Suppression Circuit Connection ICON-Procon-TVF-450-Flow-Batching-Controller- (13)

OC-Type Output Connection* ICON-Procon-TVF-450-Flow-Batching-Controller- (14)

Flow Meter Connections

TKM Series : 4-20mA Output
450 Terminal Wire Color Description
5 Brown +VDC
6 Blue -VDC
33 Yellow mA+
34 Grey mA-

ICON-Procon-TVF-450-Flow-Batching-Controller- (20)

TKS Series : Pulse Output
GPM/Pulse = K factor
450 Terminal Wire Color Description
5 Brown +VDC
6 Blue -VDC
31 Black NPN Pulse
Note : Jump 5 & 35

ICON-Procon-TVF-450-Flow-Batching-Controller- (16)

TKW Series : Pulse Output
GPM/Pulse = K factor
450 Terminal Wire Color Description
5 Brown +VDC
6 Blue -VDC
31 Black Pulse
Note : Jump 5 & 35

ICON-Procon-TVF-450-Flow-Batching-Controller- (17)

TKW Series : 4-20mA Output
450 Terminal Wire Color Description
5 Brown +VDC
6 Blue -VDC
33 Black mA+
34 White mA-

ICON-Procon-TVF-450-Flow-Batching-Controller- (18)

TKM | TKP Series : Pulse Output
GPM/Pulse = K factor
450 Terminal Wire Color Description
5 Brown +VDC
6 Blue -VDC
31 Black Pulse
Note : Jump 5 & 35

ICON-Procon-TVF-450-Flow-Batching-Controller- (19)

TIW Series : Pulse Output
GPM/Pulse = K factor
450 Terminal Wire Color Description
5 Brown +VDC
6 Blue -VDC
31 White Pulse
Note : Jump 5 & 35

ICON-Procon-TVF-450-Flow-Batching-Controller- (20)

TIM | TIP Series : Pulse Output
GPM/Pulse = K factor
450 Terminal Wire Color Description
5 Brown +VDC
6 Blue -VDC
31 White Pulse
Note : Jump 5 & 35

ICON-Procon-TVF-450-Flow-Batching-Controller- (21)

TIM Series : 4-20mA Output
450 Terminal Wire Color Description
5 Brown +VDC
6 Blue -VDC
33 Yellow mA+
34 Grey mA-

ICON-Procon-TVF-450-Flow-Batching-Controller- (21)

UF 1000 | 4000 | 5000 – Pulse Output
GPM/Pulse = K factor
450 Terminal Pin Description
5 1 +VDC
31 2 Pulse
6 3 -VDC
Note : Jump 5 & 35

ICON-Procon-TVF-450-Flow-Batching-Controller- (23)

UF 1000 | 4000 | 5000 – 4-20mA Output
450 Terminal Pin Description
5 1 +VDC
33 2 +mA
6 3 -VDC
Note : Jump 6 & 35

ICON-Procon-TVF-450-Flow-Batching-Controller- (24)

ProPulse (Flying Lead) – Pulse Output
GPM/Pulse = K factor
450 Terminal Wire Color Description
5 Red +VDC
6 Shield -VDC
31 Blue Pulse
Note : Jump 5 & 35

ICON-Procon-TVF-450-Flow-Batching-Controller- (25)

ProPulse®2 – Pulse Output
450 Terminal Wire Color Description
5 Brown +VDC
6 Blue -VDC
31 Black Pulse
Note : Jump 5 & 35

ICON-Procon-TVF-450-Flow-Batching-Controller- (26)

Programming K Factor

ICON-Procon-TVF-450-Flow-Batching-Controller- (34) ICON-Procon-TVF-450-Flow-Batching-Controller- (34)

Programming Relays

ICON-Procon-TVF-450-Flow-Batching-Controller- (34)ICON-Procon-TVF-450-Flow-Batching-Controller- (34)ICON Procon TVF-450 Flow Batching Controller User Guide Update Post Add MediaVisualText Paragraph Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 53 of 53 media items Attachment Details 5-20.png April 25, 2025 63 KB 848 by 480 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title 5 Caption Description File URL: https://manuals.plus/wp-content/uploads/2025/04/5-20.png Copy URL to clipboard Attachment Display Settings Alignment Center Link To None Size Full Size – 848 × 480 Selected media actions 1 item selected Clear Insert into post No file chosenICON Procon TVF-450 Flow Batching Controller User Guide Update Post Add MediaVisualText Paragraph Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 53 of 53 media items Attachment Details 5-20.png April 25, 2025 63 KB 848 by 480 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title 5 Caption Description File URL: https://manuals.plus/wp-content/uploads/2025/04/5-20.png Copy URL to clipboard Attachment Display Settings Alignment Center Link To None Size Full Size – 848 × 480 Selected media actions 1 item selected Clear Insert into post No file chosenICON Procon TVF-450 Flow Batching Controller User Guide Update Post Add MediaVisualText Paragraph Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 53 of 53 media items Attachment Details 5-20.png April 25, 2025 63 KB 848 by 480 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title 5 Caption Description File URL: https://manuals.plus/wp-content/uploads/2025/04/5-20.png Copy URL to clipboard Attachment Display Settings Alignment Center Link To None Size Full Size – 848 × 480 Selected media actions 1 item selected Clear Insert into post No file chosenICON-Procon-TVF-450-Flow-Batching-Controller- (31)

Programming Batching

ICON-Procon-TVF-450-Flow-Batching-Controller- (34)ICON-Procon-TVF-450-Flow-Batching-Controller- (34)ICON-Procon-TVF-450-Flow-Batching-Controller- (34)

Programming Output (For 4-20mA Output Models)

ICON-Procon-TVF-450-Flow-Batching-Controller- (34) ICON-Procon-TVF-450-Flow-Batching-Controller- (34)

ICON Procon TVF-450 Flow Batching Controller User Guide Update Post Add MediaVisualText Paragraph Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 53 of 53 media items Attachment Details 5-20.png April 25, 2025 63 KB 848 by 480 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title 5 Caption Description File URL: https://manuals.plus/wp-content/uploads/2025/04/5-20.png Copy URL to clipboard Attachment Display Settings Alignment Center Link To None Size Full Size – 848 × 480 Selected media actions 1 item selected Clear Insert into post No file chosenICON-Procon-TVF-450-Flow-Batching-Controller- (8)

Resetting BatchICON-Procon-TVF-450-Flow-Batching-Controller- (13)

Resetting Totalizer

ICON-Procon-TVF-450-Flow-Batching-Controller- (31)ICON-Procon-TVF-450-Flow-Batching-Controller- (31)

Setting Decimal Point

ICON-Procon-TVF-450-Flow-Batching-Controller- (34)ICON-Procon-TVF-450-Flow-Batching-Controller- (34)

* To change decimal points for Batch | Totalizer, select Batch | Totalizer Menu

Warranty, Returns and Limitations

Warranty
Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement.

Returns
Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective, go to www.iconprocon.com, and submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment.

Limitations
This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1) there is evidence of a potentially hazardous material present with the product; or 2) the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products.

ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE  EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY  TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada.
If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty.
For additional product documentation and technical support visit: www.iconprocon.com

Corrosion-Free Instrumentation Equipment

FAQ

  • What should I do if the unit malfunctions?
    If the unit malfunctions, disconnect it from the power supply and contact an authorized service center for repairs.
  • Can I use the unit in areas with explosive risks?
    Avoid using the unit in areas with a risk of explosions to ensure safety and prevent damage to the equipment.
  • How do I ensure correct operation in industrial installations?
    Appropriate measures should be applied to minimize interference and ensure the correct operation of the unit in industrial settings.

Documents / Resources

ICON Procon TVF-450 Flow Batching Controller [pdf] User Guide
TVF-450 Flow Batching Controller, TVF-450, Flow Batching Controller, Batching Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *