24-0340 tvf450 quickstartmanual
LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller
Quick Start Manual

Large Bright LED Display

NORYL Housing

ENC Series NEMA 4X Enclosure

TVF-450 Flow Batching Controller

Read the user's manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice.

24-0340 © Icon Process Controls Ltd.

1

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Symbol Explanation
This symbol denotes especially important guidelines concerning the installation and operation of the device. Not complying with the guidelines denoted by this symbol may cause an accident, damage or equipment destruction.

Basic Requirements | User Safety
 Do not use the unit in areas threatened with excessive shocks, vibrations, dust, humidity, corrosive gasses and oils.
 Do not use the unit in areas where there is risk of explosions.
 Do not use the unit in areas with significant temperature variations, exposure to condensation or ice.
 The manufacturer is not responsible for any damages caused by inappropriate installation, not maintaining the proper environmental conditions and using the unit contrary to its assignment.
 If in the case of a unit malfunction there is a risk of a serious threat to the safety of people or property additional, independent systems and solutions to prevent such a threat must be used.
 The unit uses dangerous voltage that can cause a lethal accident. The unit must be switched off and disconnected from the power supply prior to starting installation of troubleshooting (in the case of malfunction).
 Do not attempt to disassemble, repair or modify the unit yourself. The unit has no user serviceable parts.
 Defective units must be disconnected and submitted for repairs at an authorized service center.

Specifications

General
Display Displayed Values RS485 Transmission Housing Material Protection Class
Input Signal | Supply
Standard Voltage
Output Signal | Supply
Standard Communication Voltage Passive current output *
Performance
Accuracy
Temperatures
Operating Temperature *Optional

LED | 6 Digit | 13mm High | Red 0 ~ 999999 1200...115200 bit/s, 8N1 / 8N2 | RS485 NORYL NEMA 4X | IP65
Current: 4-20mA | 0-20mA | 0-5V* | 0-10V* 85 - 260V AC/DC | 16 - 35V AC, 19 - 50V DC*
2 x Relays (1A) | 4-20mA + 1 x Relay (1A) RS485 24VDC 4-20mA | (Operating Range Max. 2.8 - 24mA)
±0.1% @ 25°C One Digit
-4 - 122°F | -20 - 50°C

24-0340 © Icon Process Controls Ltd.

2

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller
Front Panel Description

Relay LED Indicator

Large Bright LED Display

Flow | Batching Mode LED Indicator
Push Button Programming

Function of Push Buttons

ENTER PAUSE
 RESET

Symbol used in the manual : [ESC/MENU]
Functions: · Enter to main menu ( press and hold for at least 3 sec.) · Exit the current Screen and Enter to previous menu (or measure mode) · Cancel the changes made in parameter being edited
Symbol used in the manual : [ENTER/PAUSE]
Functions: · Start to edit the parameter · Enter into the sub-menu · Confirmation of changes made in parameter being edited · In batcher mode : Pause / Start Batching
Symbol used in the manual : [  /RESET]
Functions: · Switching of the display between total and instantaneous measurements or batcher counter (In
batcher mode only) · Zeroing the currently displayed counter (Press & Hold for at least 2 Sec), the zeroing must be
confirmed by pressing [ENTER] button
Symbol used in the manual : [ ] [ ]
Functions: · Change of the present menu · Modification of the parameter value · Switching of the display between relay thresholds and number of batches counter.

24-0340 © Icon Process Controls Ltd.

3

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Dimensions

105.00

86.00

57.50 48.00 42.20
75.00

Wiring Diagram
* Depending on Version 85/230/260V AC/DC ; 50 - 60 Hz 19/24 - 50V DC ; 16/24/35V AC
Wire Connection
· Loosen Set Screw · Insert Wire · Tighten Set Screw

Power Supply* 12

89.75

Sensor

+V

-V

56789

10 11 12 13 14 15 N.C. N.C.

31 32 33 34 35

Relay 1 Relay 2

Pulse Input

mA+ mA-

Due to possible significant interference in industrial installations, appropriate measures assuring correct operation of the unit must be applied.
The unit is not equipped with an internal fuse or power supply circuit breaker.
For this reason, an external time-delay cut-out fuse with a small nominal current value must be used (recommended bipolar, max. 2A) and a power supply circuit breaker located near the unit.

24-0340 © Icon Process Controls Ltd.

4

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Power Supply & Relay Connection

1
FUSE

R4

R1

R2

R3

2

34

10 11 12 13 14 15

FUSE

Depending on Version 85/230/260V AC/DC ; 50 - 60 Hz 19/24 - 50V DC ; 16/24/35V AC
Suppression Circuit Connection
L

Note:
Contacts of relay outputs are not equipped with spark suppressors. When using the relay outputs for switching of inductive loads (coils, contactors, power relays, electromagnets, motors etc.) it is required to use additional suppression circuit (typically capacitor 47nF/ min. 250VAC in series with 100R/5W resistor), connected in parallel to relay terminals or (better) directly on the load.
L

34

34

N

N

Figure: Examples of Suppression Circuit Connection a) To Stepper Relay Terminals b) To the Inductive Load (Motor)

OC-Type Output Connection*

OC1
10 11
+
+

56
-

OC1
10 11
+

56
-
R

-

24-0340 © Icon Process Controls Ltd.

Figure: Examples of OC-type output connection

*Certain Models Only
5

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Flow Meter Connections

TKM Series : 4-20mA Output

450 Terminal Wire Color Description

5

Brown

+VDC

6

Blue

-VDC

33

Yellow

mA+

34

Grey

mA-

Power Supply (Depending on Version)
12

56789

10 11 12 13 14 15

31 32 33 34 35
mA+ mA-

TKS Series : Pulse Output

GPM/Pulse = K factor

450 Terminal Wire Color Description

5

Brown

+VDC

6

Blue

-VDC

31

Black

NPN Pulse

Note : Jump 5 & 35

Power Supply (Depending on Version)
12

Jumper Wire
56789

10 11 12 13 14 15

31 32 33 34 35

Pulse Input

TKW Series : Pulse Output

GPM/Pulse = K factor

450 Terminal Wire Color

5

Brown

Description +VDC

6

Blue

-VDC

31

Black

Pulse

Note : Jump 5 & 35

Power Supply (Depending on Version)
12

Jumper Wire
56789

10 11 12 13 14 15

31 32 33 34 35

Pulse Input

TKW Series : 4-20mA Output

450 Terminal Wire Color Description

5

Brown

+VDC

6

Blue

-VDC

33

Black

mA+

34

White

mA-

Power Supply (Depending on Version)
12

56789

10 11 12 13 14 15

31 32 33 34 35
mA+ mA-

24-0340 © Icon Process Controls Ltd.

6

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

TKM | TKP Series : Pulse Output

GPM/Pulse = K factor

450 Terminal Wire Color Description

5

Brown

+VDC

6

Blue

-VDC

31

Black

Pulse

Note : Jump 5 & 35

TIW Series : Pulse Output

GPM/Pulse = K factor

450 Terminal Wire Color Description

5

Brown

+VDC

6

Blue

-VDC

31

White

Pulse

Note : Jump 5 & 35

Power Supply (Depending on Version)
12

Jumper Wire
56789

10 11 12 13 14 15

31 32 33 34 35

Pulse Input

Power Supply (Depending on Version)
12

Jumper Wire
56789

10 11 12 13 14 15

31 32 33 34 35

Pulse Input

TIM | TIP Series : Pulse Output

GPM/Pulse = K factor

450 Terminal Wire Color

5

Brown

Description +VDC

6

Blue

-VDC

31

White

Pulse

Note : Jump 5 & 35

Power Supply (Depending on Version)
12

Jumper Wire
56789

10 11 12 13 14 15

31 32 33 34 35

Pulse Input

TIM Series : 4-20mA Output

450 Terminal Wire Color Description

5

Brown

+VDC

6

Blue

-VDC

33

Yellow

mA+

34

Grey

mA-

Power Supply (Depending on Version)
12

56789

10 11 12 13 14 15

31 32 33 34 35
mA+ mA-

24-0340 © Icon Process Controls Ltd.

7

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

UF 1000 | 4000 | 5000 ­ Pulse Output

GPM/Pulse = K factor

450 Terminal

Pin

Description

5

1

+VDC

31

2

Pulse

6

3

-VDC

Note : Jump 5 & 35

Power Supply (Depending on Version)
12

Jumper Wire
56789

10 11 12 13 14 15

31 32 33 34 35

Pulse Input

UF 1000 | 4000 | 5000 ­ 4-20mA Output

450 Terminal

Pin

Description

5

1

+VDC

33

2

+mA

6

3

-VDC

Note : Jump 6 & 35

Power Supply (Depending on Version)
12

Jumper Wire
56789

10 11 12 13 14 15

31 32 33 34 35
mA+

ProPulse (Flying Lead) ­ Pulse Output

GPM/Pulse = K factor

450 Terminal Wire Color

5

Red

Description +VDC

6

Shield

-VDC

31

Blue

Pulse

Note : Jump 5 & 35

Power Supply (Depending on Version)
12

Jumper Wire
56789

10 11 12 13 14 15

31 32 33 34 35

Pulse Input

ProPulse®2 ­ Pulse Output

450 Terminal Wire Color Description

5

Brown

+VDC

6

Blue

-VDC

31

Black

Pulse

Note : Jump 5 & 35

Power Supply (Depending on Version)
12

Jumper Wire
56789

10 11 12 13 14 15

31 32 33 34 35

Pulse Input

24-0340 © Icon Process Controls Ltd.

8

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Programming K Factor

STEPS
1

DISPLAY

Main Display



 ESC
MENU 3 Sec.

2

Relay 1



x 5

3

Input



ENTER PAUSE

4

K Factor



ENTER PAUSE

5

K Factor Value



 ENTER
PAUSE 2 Sec.

6

Save Value



ENTER PAUSE

7

K Factor



ESC MENU

8

Input



ESC

9

MENU



9

Main Display



OPERATION
MAIN DISPLAY

RELAY 1 Settings

INPUT Menu

Press or

Select PULSEL (K Factor)

Enter K FACTOR Value

Press or to change digit Press ENTER to advance to next digit
PAUSE

Note: Enter the K Factor value according to the Flow Unit. Eg: To display flow in GPM, Enter K Factor corresponding to GPM.

Save Selection

PULSEL

Input Menu Main Display

24-0340 © Icon Process Controls Ltd.

9

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Programming Relays

STEPS
1

DISPLAY

Main Display



 ESC
MENU 3 Sec.

2

Relay 1



ENTER PAUSE

3

Source



ENTER PAUSE

4

FLo | bAt | tot



ENTER PAUSE

5

Save



ENTER PAUSE

6

Source



7

Set Point 1



ENTER PAUSE

8

Set Point 1 Value



 ENTER
PAUSE 2 Sec.

9

Save



ENTER PAUSE

10

Set Point 1



OPERATION
MAIN DISPLAY

RELAY 1 Settings

SOURCE Menu

Press or

Select FLo (Flow)

Save Selection

Source

SET POINT 1

Enter SET POINT 1 Value

Press or to change digit Press ENTER to advance to next digit
PAUSE

Save Value

SET POINT 1

24-0340 © Icon Process Controls Ltd.

10

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

STEPS
11 12 13 14

Set Point 2

DISPLAY


ENTER PAUSE

Set Point 2 Value



ENTER PAUSE


2 Sec.

Save



ENTER PAUSE

Set Point 2



15

Hysterisis



ENTER PAUSE

16

Hysterisis Value



ENTER PAUSE


2 Sec.

17

Save



ENTER PAUSE

18

Hysterisis



19

Mode



ENTER PAUSE

20

On | Off | In | Out



ENTER PAUSE

OPERATION

SET POINT 2* * Option available only when the MODE is set to In/Out

Enter SET POINT 2 Value

Press or to change digit Press ENTER to advance to next digit
PAUSE

Save Value

Set Point 2

HYSTERISIS Menu

Enter HYSTERISIS Value

Press or to change digit Press ENTER to advance to next digit
PAUSE

Save Value

Hysterisis Menu

MODE Menu

Press or

Select On | OFF | In | Out

24-0340 © Icon Process Controls Ltd.

11

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

STEPS
21 22 23 24

Save
ENTER PAUSE
Mode
ESC MENU
Relay 1
ESC MENU
Main Display

DISPLAY
   

OPERATION
Save Selection Mode Menu Relay 1 Menu Main Display

10



24-0340 © Icon Process Controls Ltd.

12

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Programming Batching

STEPS
1 2 3 4 5 6

Main Display



 ESC
MENU 3 Sec.

Relay 1



ENTER PAUSE

Source



ENTER PAUSE

FLo | bAt | tot



ENTER PAUSE

Save



ENTER PAUSE

Source



DISPLAY

7

Set Point



ENTER PAUSE

8

Set Point Value



ENTER PAUSE


2 Sec.

9

Save



ENTER PAUSE

10

Set Point



ESC MENU

11

Relay 1



ESC MENU

12

Main Display



 RESET

13

Batching Mode



ENTER to start batching PAUSE

24-0340 © Icon Process Controls Ltd.

OPERATION
MAIN DISPLAY

RELAY 1 Settings

SOURCE Menu

Press or

Select bAt (Batch)

Save Selection

Source Menu

SET POINT

Enter SET POINT Value

Press or to change digit Press ENTER to advance to next digit
PAUSE

Save Value

Set Point

Relay 1 Menu

Main Display
BATCHING MODE Note: Switching between Flow rate, Totalizer and Batching can be done by pressing /RESET button. Kind of displayed value is signalised by "" LED.
 LED ON : Totalizer |  LED OFF: Flow Rate |  LED Pulsing: Batching
13

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Programming Output (For 4-20mA Output Models)

STEPS
1

DISPLAY

Main Display



 ESC
MENU 3 Sec.

OPERATION
MAIN DISPLAY

2

Relay 1



x 9

Relay 1 Settings

3

Output



ENTER PAUSE

4

Output Mode



ENTER PAUSE

5

4-20mA



ENTER PAUSE

6

Save



ENTER PAUSE

7

Output Mode



OUTPUT Menu

OUTPUT MODE

Press or

Select 4-20

Save Selection Select OUTPUT MODE

8

Source



ENTER PAUSE

9

FLo | bAt | tot



ENTER PAUSE

10

Save



ENTER PAUSE

24-0340 © Icon Process Controls Ltd.

SOURCE Menu

Press or

Select FLo (Flow)

Save Selection

14

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

STEPS
11

Source

DISPLAY


12

4mA



ENTER PAUSE

13

4mA Value



ENTER PAUSE


2 Sec.

14

Save



ENTER PAUSE

15

4mA



16

20mA



ENTER PAUSE

17

20mA Value



ENTER PAUSE


2 Sec.

18

Save



ENTER PAUSE

19

20mA



ESC MENU

20

Output



ESC MENU

21

Main Display



24-0340 © Icon Process Controls Ltd.

OPERATION
Source Menu

Setting 4mA (LOW VALUE)

Enter 4mA Value

Press or to change digit Press ENTER to advance to next digit
PAUSE

Save Value

4mA (Low Value)

Setting 20mA (HIGH VALUE)

Enter 20mA Value

Press or to change digit Press ENTER to advance to next digit
PAUSE

Save Value

20mA (High value) Output Menu Main Display
15

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Resetting Batch

STEPS
1

DISPLAY

Main Display



 ESC
MENU 3 Sec.

2

Relay 1



x 7

3

Batch Settings



ENTER PAUSE

4

Batch Resolution



x 5

5

Mode Clear



ENTER PAUSE

6

oFF | on



ENTER PAUSE

7

Save



ENTER PAUSE

8

Mode Clear



ESC MENU

9

Batch Settings



ESC MENU

10

Main Display



 RESET

OPERATION
MAIN DISPLAY

Relay 1 Settings

BATCH Menu

BATCH RESOLUTION

MODE CLEAR

Press or

Select on

Save Selection Mode Clear Batch Menu Main Display

24-0340 © Icon Process Controls Ltd.

16

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

STEPS
11
12 13

Batching Mode
 MENU
RESET 3 Sec.
Clear Batch
ENTER PAUSE
Main Display

DISPLAY

 

OPERATION
BATCHING MODE Note: Switching between Flow rate, Totalizer and Batching can be done by pressing /RESET button. Kind of displayed value is signalised by "" LED.
 LED ON : Totalizer |  LED OFF: Flow Rate |  LED Pulsing: Batching
Clear Batch
Main Display

Resetting Totalizer

STEPS
1

DISPLAY

Main Display



 ESC
MENU 3 Sec.

2

Relay 1



x 8

3

Totalizer Menu



ENTER PAUSE

4

Totalizer Resolution



x 5

5

Mode Clear



ENTER PAUSE

6

oFF | on



ENTER PAUSE

OPERATION
MAIN DISPLAY

Relay 1 Settings

TOTALIZER Menu

BATCH RESOLUTION

MODE CLEAR

Press or

Select on

24-0340 © Icon Process Controls Ltd.

17

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

STEPS
7 8 9 10
11 12 13

Save
ENTER PAUSE
Mode Clear
ESC MENU
Totalizer Menu
ESC MENU
Main Display

DISPLAY
   

 RESET

x 2

Totalizer Mode




RESET 3 Sec.

Clear



ENTER PAUSE

Main Display



OPERATION
Save Selection
Mode Clear
Totalizer Menu
Main Display TOTALIZER MODE Note: Switching between Flow rate, Totalizer and Batching can be done by pressing /RESET button. Kind of displayed value is signalised by "" LED.
 LED ON : Totalizer |  LED OFF: Flow Rate |  LED Pulsing: Batching
Clear Totalizer
Main Display

24-0340 © Icon Process Controls Ltd.

18

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller

Setting Decimal Point

STEPS
1

DISPLAY

Main Display



 ESC
MENU 3 Sec.

2

Relay 1



x 6

3

Flow Menu



ENTER PAUSE

4

Flow Precision



ENTER PAUSE

5

Decimal Point



ENTER PAUSE

6



OPERATION
MAIN DISPLAY

Relay 1 Settings

FLOW Menu *

FLOW PRECISION

DECIMAL POINT

Press or

to change Decimcal Point

6

Save



ENTER PAUSE

7

Flow Precision



ESC MENU

8

Flow Menu



ESC MENU

9

Main Display



Save Selection Flow Precision Flow Menu Main Display

24-0340 © Icon Process Controls Ltd.

* To change decimal points for Batch | Totalizer, select Batch | Totalizer Menu
19

LevelPro® -- TVF-450 Series
Industrial Flow Batching Controller
Warranty, Returns and Limitations
Warranty
Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement.
Returns
Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective, go to www.iconprocon.com, and submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment.
Limitations
This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1) there is evidence of a potentially hazardous material present with the product; or 2) the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada.
If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty.