Zigbee WIFI Radiator Actuator User Manual
HY368 Zigbee WIFI Radiator Actuator
Many thanks for your selection of our products and services, and also for your trust and support to us.
Download “Smart life” or “Smart RM” App from Google play and App store |
1. After the ZigBee gateway is configured, enter the gateway to add sub-devices, and wait for the actuator to be powered on and the system self-check is completed. 2.long press ![]() ![]() ![]() ![]() ![]() ![]() |
Product Specifications
Power: 2* AAalkalinebatteries
Displayaccuracy::0.5℃
Probesensor::NTC(10k)1%
Maximumroute:4.5mm
Working temperature: 0-50℃
Running program: Set per 1 week as acycle
Size(mm):53*89.5mm
Range of temperature display::1~70°C
Default range oftemperatureadjustment:5~35°C Maximum current:90mA
Workingenvironmenttemperature::-10~60°C Threadsize:M30*1.5
Displays & Buttons
No. | Icon | |
A | ![]() ![]() ![]() ![]() |
![]() |
B | ![]() ![]() ![]() ![]() ![]() ![]() |
|
C | Time setting interface:![]() ![]() |
No | keys | Represen |
D | ![]() |
1.Short press to switch manual mode and auto mode 2.Long press to enter advanced settings 3.Confirm key |
E | ![]() |
1.Decrease key 2.Long press 3s to lock/unlock keys |
F | ![]() |
1.Increase Key 2.Long press 3 seconds to start the BOOST function: turn on the BOOST fast heating mode, short press any key during operation to exit this function and return to the previous working mode |
Installation and initial commissioning
After power on, the screen will show all for 3 seconds.
Time setting: when flashing,thenpress
display
valueadjust value,press again,press again to set week,press
Increase Key
Long press 3 seconds to start the BOOST function: turn on the BOOST fast heating mode, short press any key during operation to exit this function and return to the previous working mode Installation and initial commissioning ,display enter hour setting,press or enter minute setting,press to adjust value,press
or
or to to adjust to confirm setting and remember time.
Note: after the actuator completes its self-check,under normal working status,if need to modify time, long press 3s access to advanced setting. And press entertime setting. the same as above method. When display “Ad”, press
to choose , short press
Start system self-check, when display “1”, this is the first step of system self-check.
When Display “2”, this is the second step for self-check, after finish self-check, If there is no fault prompt, it will enter the normal working state. If there is a fault prompt, please handle the fault first, otherwise it will not enter the normal working state.
E1 | Motor fault |
E2 | Sensor fault |
![]() |
Flashing show low battery |
Special Function description
Holiday mode | press 3s access to advanced settings,shortpress to choose holiday mode,then shortpress enter temperature setting, again short press setting day ssetting,press or to adjust value. Under holiday mode, short press to exit holiday mode |
Open | 1. The actuator turns off the window opening function by default, if you need to |
Window Function | use it, you can turn it on in the advanced option 2 setting [reset disable when changing the battery] |
Auto mode setting
Long press about 3s accesst o advanced settings, short press
,short press access to auto mode setting,
short press
switch to auto mode setting to choose which item you want, First set the auto mode to 5means:5=5+2days,6= 6+1 days, 7 = 7 days, afterpress
to access to hour or minute setting, short press
access to temperature setting. Press
or
to adjust value. short press choose: hour,minute, time period, and press 10 seconds will automatic save and exist.
Period | Default period | Default temperature |
1 | 6:00-8:00 | 20℃ |
2 | 8:00-11:30 | 15℃ |
3 | 11:30—12:30 | 15℃ |
4 | 12:30—17:30 | 15℃ |
5 | 17:30—22:00 | 20℃ |
6 | 22:00—6:00 | 15℃ |
Advanced options
Press about3-5 sto access to advanced settings, short press until flashing, press to access to advanced options, press or to adjust value,after finish setting every time, short press to setn ext option,after finishing all ,don’t operate, after 10s it will automatically save and exit.
No | Item | Setting parameters |
default |
1 | Measuring temperature correction | -9-+9°C(Displayed as the corrected room temperature value) | -1°C |
2 | Open window function parameter: temperature and running time | 1:display![]() 2:Running time:5-60min(after enable function, press ![]() |
![]() |
3 | Automatic lock if no operation more than 10 minutes | 0:Disable 1: Enable | 0 |
4 | Setting temperature minimum limit | 1-15°C | 5°C |
5 | Setting temperature maximum limit | 16-70°C | 35°C |
6 | BOOST mode running time | 100s-900s, Steps of 100 seconds | 300Seconds |
7 | View valve open status | 0-99 99 mean valve open 100% 5 mean valve open 5% | |
8 | Start/stop working temperature difference setting | 0.5-1.5 | 1 |
9 | Display mode | 0:Upward display 1:Downward display | 0 |
A | Control type of valve | 0: PID 1:FLOAT 2:0N/OFF | |
B | Reset | Display88, using+ ormtochange to 00, press![]() ![]() |
|
C | Valve Seal Type | 0:Soft Seal 1:Hard Seal | |
D | Descaling function | 0: Disable descaling function 1: Enable descaling function | 1 |
Documents / Resources
![]() |
hysencontrol HY368 Zigbee WIFI Radiator Actuator [pdf] User Manual HY368 Zigbee WIFI Radiator Actuator, HY368, Zigbee WIFI Radiator Actuator, WIFI Radiator Actuator, Radiator Actuator |