HY368 ?rnd=863
Zigbee WIFI Radiator Actuator User Manual

Many thanks for your selection of our products and services, and also for your trust and support

to us. Download "Smart life" 1. After the ZigBee gateway is configured, enter the gateway to add

or "Smart RM" App from sub-devices, and wait for the actuator to be powered on and the system

Google play and App self-check is completed.

store

2.long press

enter tosetting surface ,short press to choose

icon,short press

to enter network connected mode, then long press

, flashing access network connected mode. Please refer to the gateway manual for Zigbee gateway configuration.

Product Specifications
Power: 2* AAalkalinebatteries

Working temperature: 0-50

Displayaccuracy:0.5 Probesensor:NTC(10k)1% Maximumroute4.5mm

Running program: Set per 1 week as acycle Size(mm)53*89.5mm Range of temperature display:1~70°C

Default range oftemperatureadjustment5~35°C Maximum current90mA

Workingenvironmenttemperature:-10~60°C ThreadsizeM30*1.5

Displays & Buttons

No.

Icon

A

Auto Mode; Holiday mode; Boost mode; Open Window function

Low battery; Children lock;

2.Long press 3s to lock/unlock keys

F

1.Increase Key

2.Long press 3 seconds to start the BOOST function: turn on the BOOST fast heating

mode, short press any key during operation to exit this function and return to the

previous working mode

Installation and initial commissioning

After power on, the screen will show all for 3 seconds.

Time setting: when

flashing,thenpress ,display enter hour setting,press or

to

adjust value,press again display value,press again to set week,press

enter minute setting,press

or

to adjust

or

to adjust value,press to confirm setting and

remember time.

Note: after the actuator completes its self-check,under normal working status,if need to modify

time, long press 3s access to advanced setting. And press tochoose

, short press

entertime setting. the same as above method.

When display "Ad", press

Start system self-check, when display "1", this is the first step of

system self-check. When Display "2", this is the second step for self-check, after finish self-check, If

there is no fault prompt, it will enter the normal working state. If there is a fault prompt, please handle the fault first, otherwise it will not enter the normal working state.

B

Zigbee connection status Auto mode period

Set temperature/Advanced options

Valve status

C Time setting interface: hour setting; minute setting

No. keys Represent

D

1.Short press to switch manual mode and auto mode

2.Long press to enter advanced settings

3.Confirm key

E

1.Decrease key

E1

Motor fault

E2

Sensor fault

Flashing show low battery

Special Function description

Holiday mode

press 3s access to advanced settings,shortpress to choose holiday mode , then shortpress entertemperaturesetting, again short press setting days setting,press or to adjust value. Under holiday mode, short press to exit holiday mode.

Open

1. The actuator turns off the window opening function by default, if you need to

WindowFunction use it, you can turn it on in the advanced option 2 setting [reset disable when changing the battery]

Auto mode setting
Long press about 3s accessto advanced settings, short press switch to auto mode setting

,short press access toauto mode setting, short press to choose which item you want, First set the auto mode to 5means:5= 5+2days,6= 6+1 days, 7 = 7 days, afterpress to access to hour or

minute setting, short press access to temperature setting. Press or to adjust value.

short press choose: hour,minute, time period, and press

10 seconds will automatic save and exist.

Period 1 2 3 4 5 6

Default period 6:00-8:00 8:00-11:30
11:30--12:30 12:30--17:30 17:30--22:00
22:00--6:00

or to adjust data, finished setting, about
Default temperature 20 15 15 15 20 15

Advanced options

Press about3-5stoaccessto advanced settings, short press until flashing, press to access to advancedoptions, press or toadjustvalue,after finish setting every time, short press tosetnextoption,after finishing all ,don't operate, after 10s it will automatically save andexit.

No

Item

Setting parameters

default

1

Measuring temperature correction

-9-+9(Displayed as the corrected room temperature value)

-1°C

1:display

means disable open

Open window

window function,press key display 5°C

2 functionparameter: temperature and

means this function enable(temperature setting range: 5-25°C)

running time

2:Running time:5-60min(after enable

function, press change setting)

Automatic lock if no

0:Disable

3

operation more than 10 minutes

1: Enable

0

Setting temperature

4

minimum limit

1-15°C

Setting temperature

5

maximum limit

16-70°C

BOOSTmode running

6

time

100s-900s , Steps of 100 seconds

0-99

7

View valve open status 99 mean valve open 100%

5 mean valve open 5%

Start/stop working

8

temperature difference setting

0.5-1.5

9

Display mode

0:Upward display 1:Downward display

5°C 35°C 300Seconds
1 0

A

Control type of valve

0: PID 1:FLOAT 2:ON/OFF

Display88, using or tochange

B

Reset

to 00, press to reset, The screen will be

fully displayed for 2 seconds.

C

Valve Seal Type

0:Soft Seal 1:Hard Seal

0: Disable descaling function

D

Descaling function

1: Enable descaling function

1

