User Manual for hysencontrol models including: HY368 Zigbee WIFI Radiator Actuator, HY368, Zigbee WIFI Radiator Actuator, WIFI Radiator Actuator, Radiator Actuator
Smart Radiator Trv Manufacturers - Customized Smart Radiator Trv
Thermostatic Radiator Valve Adapter Manufacturers Suppliers - Customized Service
Zigbee WIFI Radiator Actuator User Manual Many thanks for your selection of our products and services, and also for your trust and support to us. Download "Smart life" 1. After the ZigBee gateway is configured, enter the gateway to add or "Smart RM" App from sub-devices, and wait for the actuator to be powered on and the system Google play and App self-check is completed. store 2.long press enter tosetting surface ,short press to choose icon,short press to enter network connected mode, then long press , flashing access network connected mode. Please refer to the gateway manual for Zigbee gateway configuration. Product Specifications Power: 2* AAalkalinebatteries Working temperature: 0-50 Displayaccuracy:0.5 Probesensor:NTC(10k)1% Maximumroute4.5mm Running program: Set per 1 week as acycle Size(mm)53*89.5mm Range of temperature display:1~70°C Default range oftemperatureadjustment5~35°C Maximum current90mA Workingenvironmenttemperature:-10~60°C ThreadsizeM30*1.5 Displays & Buttons No. Icon A Auto Mode; Holiday mode; Boost mode; Open Window function Low battery; Children lock; 2.Long press 3s to lock/unlock keys F 1.Increase Key 2.Long press 3 seconds to start the BOOST function: turn on the BOOST fast heating mode, short press any key during operation to exit this function and return to the previous working mode Installation and initial commissioning After power on, the screen will show all for 3 seconds. Time setting: when flashing,thenpress ,display enter hour setting,press or to adjust value,press again display value,press again to set week,press enter minute setting,press or to adjust or to adjust value,press to confirm setting and remember time. Note: after the actuator completes its self-check,under normal working status,if need to modify time, long press 3s access to advanced setting. And press tochoose , short press entertime setting. the same as above method. When display "Ad", press Start system self-check, when display "1", this is the first step of system self-check. When Display "2", this is the second step for self-check, after finish self-check, If there is no fault prompt, it will enter the normal working state. If there is a fault prompt, please handle the fault first, otherwise it will not enter the normal working state. B Zigbee connection status Auto mode period Set temperature/Advanced options Valve status C Time setting interface: hour setting; minute setting No. keys Represent D 1.Short press to switch manual mode and auto mode 2.Long press to enter advanced settings 3.Confirm key E 1.Decrease key E1 Motor fault E2 Sensor fault Flashing show low battery Special Function description Holiday mode press 3s access to advanced settings,shortpress to choose holiday mode , then shortpress entertemperaturesetting, again short press setting days setting,press or to adjust value. Under holiday mode, short press to exit holiday mode. Open 1. The actuator turns off the window opening function by default, if you need to WindowFunction use it, you can turn it on in the advanced option 2 setting [reset disable when changing the battery] Auto mode setting Long press about 3s accessto advanced settings, short press switch to auto mode setting ,short press access toauto mode setting, short press to choose which item you want, First set the auto mode to 5means:5= 5+2days,6= 6+1 days, 7 = 7 days, afterpress to access to hour or minute setting, short press access to temperature setting. Press or to adjust value. short press choose: hour,minute, time period, and press 10 seconds will automatic save and exist. Period 1 2 3 4 5 6 Default period 6:00-8:00 8:00-11:30 11:30--12:30 12:30--17:30 17:30--22:00 22:00--6:00 or to adjust data, finished setting, about Default temperature 20 15 15 15 20 15 Advanced options Press about3-5stoaccessto advanced settings, short press until flashing, press to access to advancedoptions, press or toadjustvalue,after finish setting every time, short press tosetnextoption,after finishing all ,don't operate, after 10s it will automatically save andexit. No Item Setting parameters default 1 Measuring temperature correction -9-+9(Displayed as the corrected room temperature value) -1°C 1:display means disable open Open window window function,press key display 5°C 2 functionparameter: temperature and means this function enable(temperature setting range: 5-25°C) running time 2:Running time:5-60min(after enable function, press change setting) Automatic lock if no 0:Disable 3 operation more than 10 minutes 1: Enable 0 Setting temperature 4 minimum limit 1-15°C Setting temperature 5 maximum limit 16-70°C BOOSTmode running 6 time 100s-900s , Steps of 100 seconds 0-99 7 View valve open status 99 mean valve open 100% 5 mean valve open 5% Start/stop working 8 temperature difference setting 0.5-1.5 9 Display mode 0:Upward display 1:Downward display 5°C 35°C 300Seconds 1 0 A Control type of valve 0: PID 1:FLOAT 2:ON/OFF Display88, using or tochange B Reset to 00, press to reset, The screen will be fully displayed for 2 seconds. C Valve Seal Type 0:Soft Seal 1:Hard Seal 0: Disable descaling function D Descaling function 1: Enable descaling function 1WPS 文字