HYDC SCT016S 50A Split Core Current Transformer
Specifications
- Model: SCT016S
- Input Current: 50A – 200A
- Output: 100mA
- Turns Ratio: 1100 – 14000
- Load Resistance: 5 – 10
- Accuracy: 0.5% – 1%
- Linearity: 1%
- Weight: 85g
OVERVIEW
Ф16mmAperture Split core current transformer
Characteristic
- Safety lock buckle, easy to install
- Built-in over-voltage protection device (TVS tube)
- Lead type output and length can be customized
- Suspended type
Product application
- Portable instrument
- Household metering
- Monitor motor load
Product advantage
- Small volume, lightweight
- Low cost
- High turns, high precision
Installation diagram
Primary threading method(Firing line)
Typical technical index
- Material of core——Silicon steel sheet
- Working voltage——Phase voltage≤720V
- Working temperature——-25℃~+60℃
- Storage temperature——-30℃~+90℃
- Frequency range——50Hz~60Hz
- Dielectric strength——Input(bare conductor)/output AC 800V/1min 5mA 50Hz Output/Outer shell AC 3.5KV/1min 5mA 50Hz
Electrical parameters:( The following parameters are typical values and actual values will be subject to product testing) | |||||||||||
Max. continuous input current: 120% of rated input | |||||||||||
Model | Input
current |
Output | Turns ratio | Load
resistance |
Accuracy | Linearity | Weight | ||||
SCT016S | 50A | 100mA
100mA |
1:100 | 5Ω | 1% | 1% | 85g
85g |
||||
SCT016S | 100A | 1:1000 | 5Ω | 0.5%/1% | 1% | ||||||
SCT016S | 120A | 40mA | 1:3000 | 10Ω | 0.5%/1% | 1% | 85g | ||||
SCT016S | 150A | 100mA | 1:1500 | 10Ω | 0.5%/1% | 1% | 85g | ||||
SCT016S | 150A | 50mA | 1:3000 | 10Ω | 0.5%/1% | 1% | 85g | ||||
SCT016S | 160A | 40mA | 1:4000 | 10Ω | 0.5%/1% | 1% | 85g | ||||
SCT016S | 200A | 100mA
50mA |
1:2000 | 10Ω | 0.5%/1% | 1% | 85g
85g |
||||
1:4000 | 10Ω | 0.5%/1% | 1% | ||||||||
SCT016S | 200A | ||||||||||
Model | Input
current |
Output | Turns ratio | Power | Accuracy | Linearity | Weight | ||||
SCT016S | 60A | 1A
1A |
1:60 | 0.1VA | 1% | 1% | 85g
85g |
||||
SCT016S | 80A | 1:80 | 0.1VA | 1% | 1% | ||||||
SCT016S | 100A | 1A | 1:100 | 0.1VA | 1% | 1% | 85g | ||||
Model | Input
current |
Output | Turns ratio | Load
resistance |
Accuracy | Linearity | Weight | ||||
SCT016S | 50A | 0.333V
0.333V |
– | built-in | 0.5%/1% | 1% | 85g
85g |
||||
SCT016S | 100A | – | built-in | 0.5%/1% | 1% | ||||||
SCT016S | 150A | 0.333V | – | built-in | 0.5%/1% | 1% | 85g |
Can be customized parameters/lead length/lead specifications according to user requirements.
Wiring schematic diagram
- Built-in sampling resistance Voltage output type,
- Secondary doesn’t allow short circuit
TVS: Transient voltage suppressor Current output type,
Secondary doesn’t allow open circuit
Cable (AWG22)
Specifications of lead wire: 20.3mm black and white twisted pair: (1AOutput: 0.75mm black and white twisted pair)
- The length of lead wire: 50cm
- Color of lead wire: white, black
Outline size: (in: mm)
FAQ
- Can the parameters of the current transformer be customized?
- Yes, parameters such as lead length and specifications can be customized according to user requirements.
- What is the maximum continuous input current supported by the SCT016S?
- The maximum continuous input current supported is 120% of the rated input for optimal performance.
Documents / Resources
![]() |