SPECIFICATIONS
Operating Specifications
- Station Run Time: 1 minute to 6 hours on programs A, B, and C
- Start Times: 4 per program, three programs for up to 12 starts
- Watering Schedule: 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming, made possible by the 365-day clock/calendar
Electrical Specifications
- Transformer Input: 120 VAC, 60 hz (230 VAC, 50/60 hz International Use)
- Transformer Output: 24 VAC, 1 amp
- Station Output: 24 VAC, 0.56 amps per station
- Maximum Output: 24 VAC, 0.84 amps (includes Master Valve Circuit)
- Battery: 9-volt alkaline battery (not included) used only for non-AC programming, the non-volatile memory maintains program information
- Battery, front panel, internal CR2032 lithium for real-time clock
Cabinet Dimensions
Height: 9″ (23 cm)
Width: 10″ (21.5 cm)
Depth: 4.5″ (10.9 cm)
Outdoor cabinet is NEMA 3R, IP44 rated.
Default Settings
All stations are set to zero run time. This controller has a non-volatile memory that retains all entered program data even during power outages, without need for a battery.
Cleaning
Clean only with cloth dampened with mild soapy water.
PRO-C COMPONENTS






Questions about your Manual? Post in the comments!
Hunter Pro-C PC Series Mdular Controller Owner’s Manual and Installation Instructions – Original PDF
Hunter Pro-C PC Series Modular Controller Owner’s Manual and Installation Instructions – Original PDF
Hunter Pro-C Light Commercial Irrigation Controllers Owner’s Manual and Installation Instructions – Original PDF
Specifications
| Controller Type | Hunter Residential and Light Commercial Irrigation Controller |
| Series | PC Series |
| Modular Controller | Yes |
| Indoor/Outdoor Models | Yes |
| Station Run Time | 1 minute to 6 hours on programs A, B, and C |
| Start Times | 4 per program, three programs for up to 12 starts |
| Watering Schedule | 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming, made possible by the 365-day clock/calendar |
| Transformer Input | 120 VAC, 60 hz (230 VAC, 50/60 hz International Use) |
| Transformer Output | 24 VAC, 1 amp |
| Station Output | 24 VAC, 0.56 amps per station |
| Maximum Output | 24 VAC, 0.84 amps (includes Master Valve Circuit) |
| Battery | 9-volt alkaline battery (not included) used only for non-AC programming, the non-volatile memory maintains program information. Front panel, internal CR2032 lithium for real-time clock |
| Cabinet Dimensions | Height: 9″ (23 cm) Width: 10″ (21.5 cm) Depth: 4.5″ (10.9 cm). Outdoor cabinet is NEMA 3R, IP44 rated. |
| Default Settings | All stations are set to zero run time. This controller has a non-volatile memory that retains all entered program data even during power outages, without need for a battery. |
FAQs
Yes you have to reset the box again
Yes. The base model controls 4 zones. Add up to 3 more 4 station modules to control up to 16 zones!
I’m not real familiar with the 400, but the 400i can be expanded to 16 zones with added snap in modules.
2 Years.
Yes, it works with the ROAM remote system.
Input 120 VAC, output 24 VAC
If u are talking about a timer function – yes it does
Yes. It should come with an AC adapter. The outdoor model needs to be either hard wired or you can strip a grounded extension cord and wire it that way.
You can program the unit to run daily or only on specific days of the week. Once every 7 day
Is the longest interval. You can download the operators manual from the Hunter website
This is the base unit only, with no expansion modules. The base unit can control 4 zones.
Yes, this is a great replacement for the SRC timer.
The station run time is 1 minute to 6 hours on programs A, B, and C. The start times are 4 per program, three programs for up to 12 starts. The watering schedule is a 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming, made possible by the 365-day clock/calendar.
The transformer input is 120 VAC, 60 hz (230 VAC, 50/60 hz International Use). The transformer output is 24 VAC, 1 amp. The station output is 24 VAC, 0.56 amps per station. The maximum output is 24 VAC, 0.84 amps (includes Master Valve Circuit). The battery required is a 9-volt alkaline battery (not included) used only for non-AC programming, the non-volatile memory maintains program information. The battery for the front panel is an internal CR2032 lithium for real-time clock.
The height is 9″ (23 cm), width is 10″ (21.5 cm), and depth is 4.5″ (10.9 cm). The outdoor cabinet is NEMA 3R, IP44 rated.
Video
References
- User Manualmanual.tools

I need some help. In Spanish please!
Can you provide help for the Hunter Pro C irrigation controller in Spanish?
Para ayudarle con su controlador Hunter Pro-C, aquí tiene los pasos básicos de programación:
Puede descargar el manual original en PDF desde esta página para ver más detalles técnicos. Si tiene una pregunta específica sobre un error o instalación, por favor háganoslo saber.
Read the full Q&A page
Somehow our sprinklers got set to come on twice a day. How do I change that back to once a day, or on the days I choose?
How do I reduce the number of daily start times and select specific watering days on my Hunter Pro-C controller?
To change your Hunter Pro-C from watering twice a day to once a day, or to select specific days, follow these steps:
1. Remove Extra Start Times (To stop it from running twice)
2. Select Specific Watering Days
Once finished, turn the dial back to the RUN position for the new schedule to take effect.
Read the full Q&A page
I am having this same issue. Went through the entire program but everything says 5am/10min per zone/5 zones… noticed this weekend it ran at 5am and again at 7am.
Hello, the screen shows me the information and it is deleted immediately, what can happen with this? Thanks
Hola la pantalla me muestra la información y se borra de inmediato que puede pasar con esto? Gracias
Hola la pantalla me muestra la información y se borra de inmediato que puede pasar con esto? Gracias
Why does the screen information disappear immediately after appearing?
If your Hunter Pro-C screen displays information briefly and then disappears, it usually indicates a power supply issue or a problem with the faceplate connection. Please check the following:
If the screen remains blank even with confirmed AC power, the internal CR2032 lithium battery (for the clock) or the faceplate itself may need replacement.
Note: The Pro-C has non-volatile memory, so your programming should be safe even if the display is currently off.
Read the full Q&A page
I am unable to program the 4th water zone on my Hunter Pro-C unit. It was programed but when i added the second day to run the sprinkler the 4th Zone is not there anymore.
Why is Zone 4 missing from my Hunter Pro-C controller after I changed the watering days?
If Zone 4 has disappeared from your Hunter Pro-C controller, it is likely due to one of the following reasons related to how the modular system and programming work:
If the zone still does not appear, ensure the module locking bar is fully engaged, as this is the most common cause for the controller "losing" zones.
Read the full Q&A page
I programmed A To run through four zones, when it’s finished it just runs through A again and doesn’t shut off any suggestions
Why does my Hunter Pro-C controller repeat the watering cycle for Program A instead of shutting off?
The most common reason a Hunter Pro-C controller repeats a cycle is that multiple Start Times have been programmed for the same program. On the Pro-C, a single Start Time will automatically run all zones assigned to that program in sequence. If you have set a second, third, or fourth start time, the controller will restart the entire sequence once the first one finishes.
To fix this, follow these steps:
If the issue persists, ensure you do not have overlapping start times on Programs B or C that might be triggering additional cycles.
Note: Only one start time is required to run all zones in a program.
Reference: Hunter Pro-C User Manual, "Setting Program Start Times" section.
Read the full Q&A page
Where is the manual for the older Pro-C??
Where can I find the manual for the older Hunter Pro-C irrigation controller models?
The manual for the older Hunter Pro-C (PC Series) modular controller is available on this page. You can access the original PDF versions using the links below:
If your unit is a legacy model (pre-2004) or you are looking for a specific older revision not covered by these documents, you can also use the Manuals+ Deep Search tool or visit the Hunter Industries website's support section, which maintains an archive of discontinued product manuals.
Read the full Q&A page
When we use the manual control to water, it has the correct number of stations (7) that our sprinkler system contains.
We want to set the program control to water, but we can only view four (4) of the seven (7) stations we have. How can I program the other three stations three missing stations or add them back?
We want to set the program control to water, but we can only view four (4) of the seven (7) stations we have. How can I program the other three stations three missing stations or add them back?
How do I program stations 5, 6, and 7 on my Hunter Pro-C controller when only stations 1-4 are visible in the program settings?
If you can manually operate all 7 stations but cannot see them during programming, it usually means the controller has not yet "recognized" the expansion modules or the run times for those specific stations are currently set to zero.
To add or view the missing stations (5, 6, and 7) for your automatic schedule, follow these steps:
Note: If the stations work in manual mode, the modules are physically connected, so a quick power cycle or checking the RUN TIMES dial position specifically is the most likely fix.
Read the full Q&A page
We had an electrical storm last week that caused our sprinkler system to come on. We could not stop it without pulling the electrical cord from the socket. Now were having trouble reprograming the system. Can you help?
How do I reprogram the Hunter Pro-C controller after a power surge or electrical storm?
Electrical storms can sometimes cause the controller to behave erratically. Since you had to pull the plug to stop the system, it is recommended to perform a Full Reset before attempting to reprogram. This clears the memory and ensures no 'glitch' data remains.
To Reset the Controller:
Basic Reprogramming Steps:
Finally, turn the dial back to RUN. If the system still fails to respond or stations stay on constantly, the electrical storm may have damaged the internal solenoid valves or the controller's power module, which might require professional inspection.
Read the full Q&A page
Is there a way to reset the entire program, so I can start over? I thought I had corrected everything that was mistakenly set, and now it has started running on off days.
How do I perform a full factory reset on the Hunter Pro-C controller to clear all programming?
To clear all programmed data and return the Hunter Pro-C controller to its original factory defaults, follow these steps for a Full Reset:
Note: This will erase all start times, run times, and water days across all programs (A, B, and C). If your controller is running on "off days," also ensure you check that you haven't accidentally set an Odd/Even or Interval schedule instead of a 7-day calendar schedule.
Read the full Q&A page
I’m having trouble with the rain sensor for a Hunter Pro-C controller. Should the button be up covering “bypass” or down leaving “active” covered.
Thanks
Thanks
How should the rain sensor bypass switch be positioned on the Hunter Pro-C controller?
To ensure your rain sensor is functioning and able to stop watering during rain, the switch should be in the down position, which leaves the "ACTIVE" label visible (or uncovered).
If you want the controller to ignore the sensor and water even when it is raining, you should slide the switch up to the "BYPASS" position. When the switch is in the Active position and the sensor is wet, the display will typically show "OFF" or a sensor icon to indicate that watering is being suspended.
Read the full Q&A page
现在 Hunter Pro-C 装置上编程都停了,不工作,应该怎么调节
The Hunter Pro-C programming has stopped and it is not working. How should I adjust it?
If your Hunter Pro-C controller has stopped working or the programming is not initiating, please check the following steps to troubleshoot and adjust the settings:
To test the system immediately, you can turn the dial to MANUAL-SINGLE STATION, select a station, and turn the dial back to RUN to see if the valves activate.
Read the full Q&A page