The Hunter Pro C Manual Start User Guide for Irrigation Controller is a comprehensive guide that provides detailed information on the Hunter Pro C irrigation controller. This guide is designed to help users understand the specifications and electrical requirements of the Hunter Pro C controller, as well as its various features and functions. The Hunter Pro C is a modular controller that can be used for both residential and light commercial applications, and it comes in both indoor and outdoor models. The guide provides information on the controller’s operating specifications, including station run time, start times, and watering schedules. It also includes details on the electrical specifications of the controller, such as transformer input and output, station output, and battery requirements. Additionally, the guide provides information on the default settings of the controller, as well as cleaning instructions and frequently asked questions. Overall, the Hunter Pro C Manual Start User Guide is an essential resource for anyone who wants to get the most out of their Hunter Pro C irrigation controller.

Hunter-Pro-C-fig-1Hunter Pro C

Hunter Pro C

Hunter Residential and Light Commercial Irrigation Controller
PC Series
Modular Controller
Indoor/Outdoor Models

SPECIFICATIONS

Operating Specifications

  • Station Run Time: 1 minute to 6 hours on programs A, B, and C
  • Start Times: 4 per program, three programs for up to 12 starts
  • Watering Schedule: 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming, made possible by the 365-day clock/calendar

Electrical Specifications

  • Transformer Input: 120 VAC, 60 hz (230 VAC, 50/60 hz International Use)
  • Transformer Output: 24 VAC, 1 amp
  • Station Output: 24 VAC, 0.56 amps per station
  • Maximum Output: 24 VAC, 0.84 amps (includes Master Valve Circuit)
  • Battery: 9-volt alkaline battery (not included) used only for non-AC programming, the non-volatile memory maintains program information
  • Battery, front panel, internal CR2032 lithium for real-time clock

Cabinet Dimensions

Height: 9″ (23 cm)
Width: 10″ (21.5 cm)
Depth: 4.5″ (10.9 cm)
Outdoor cabinet is NEMA 3R, IP44 rated.

Default Settings
All stations are set to zero run time. This controller has a non-volatile memory that retains all entered program data even during power outages, without need for a battery.

Cleaning
Clean only with cloth dampened with mild soapy water.

PRO-C COMPONENTS

PRO-C COMPONENTS
LCD Display
PRO-C COMPONENTS
Control Dial
Wiring Compartment

Questions about your Manual? Post in the comments!
Hunter Pro-C PC Series Mdular Controller Owner’s Manual and Installation Instructions – Original PDF
Hunter Pro-C PC Series Mdular Controller

Hunter Pro-C PC Series Modular Controller Owner’s Manual and Installation Instructions – Original PDF
Hunter Pro-C PC Series Modular Controller

Hunter Pro-C Light Commercial Irrigation Controllers Owner’s Manual and Installation Instructions – Original PDF
Hunter Pro-C  Light Commercial Irrigation Controllers

Specifications

Controller Type Hunter Residential and Light Commercial Irrigation Controller
Series PC Series
Modular Controller Yes
Indoor/Outdoor Models Yes
Station Run Time 1 minute to 6 hours on programs A, B, and C
Start Times 4 per program, three programs for up to 12 starts
Watering Schedule 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming, made possible by the 365-day clock/calendar
Transformer Input 120 VAC, 60 hz (230 VAC, 50/60 hz International Use)
Transformer Output 24 VAC, 1 amp
Station Output 24 VAC, 0.56 amps per station
Maximum Output 24 VAC, 0.84 amps (includes Master Valve Circuit)
Battery 9-volt alkaline battery (not included) used only for non-AC programming, the non-volatile memory maintains program information. Front panel, internal CR2032 lithium for real-time clock
Cabinet Dimensions Height: 9″ (23 cm) Width: 10″ (21.5 cm) Depth: 4.5″ (10.9 cm). Outdoor cabinet is NEMA 3R, IP44 rated.
Default Settings All stations are set to zero run time. This controller has a non-volatile memory that retains all entered program data even during power outages, without need for a battery.

FAQs

Do you need to reset the unit if the house loses electricity?

Yes you have to reset the box again

Does this include the 4 zone module?

Yes. The base model controls 4 zones. Add up to 3 more 4 station modules to control up to 16 zones!

what is the difference between hunter model pc-400 vs pc-400i?

I’m not real familiar with the 400, but the 400i can be expanded to 16 zones with added snap in modules. 

What is Hunter Warranty on this product?

2 Years.

Can I add a remote to the 400i?

Yes, it works with the ROAM remote system.

What is input output voltage?

Input 120 VAC, output 24 VAC

Does this model have a delay function?

If u are talking about a timer function – yes it does

Can this controller be plugged into a wall outlet or does it need to be hard wired?

Yes. It should come with an AC adapter. The outdoor model needs to be either hard wired or you can strip a grounded extension cord and wire it that way.

Can this unit be programmed for intervals — such as watering every 10 days or however many you want?

You can program the unit to run daily or only on specific days of the week. Once every 7 day
Is the longest interval. You can download the operators manual from the Hunter website

Does it come with modules? If so, what configuration?

This is the base unit only, with no expansion modules. The base unit can control 4 zones.

Is this compatible with hunter src?

Yes, this is a great replacement for the SRC timer.

What are the operating specifications of the Hunter Pro C irrigation controller?

The station run time is 1 minute to 6 hours on programs A, B, and C. The start times are 4 per program, three programs for up to 12 starts. The watering schedule is a 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming, made possible by the 365-day clock/calendar.

What are the electrical specifications of the Hunter Pro C irrigation controller?

The transformer input is 120 VAC, 60 hz (230 VAC, 50/60 hz International Use). The transformer output is 24 VAC, 1 amp. The station output is 24 VAC, 0.56 amps per station. The maximum output is 24 VAC, 0.84 amps (includes Master Valve Circuit). The battery required is a 9-volt alkaline battery (not included) used only for non-AC programming, the non-volatile memory maintains program information. The battery for the front panel is an internal CR2032 lithium for real-time clock.

What are the dimensions of the Hunter Pro C irrigation controller cabinet?

The height is 9″ (23 cm), width is 10″ (21.5 cm), and depth is 4.5″ (10.9 cm). The outdoor cabinet is NEMA 3R, IP44 rated.

References

Questions and answers

Helpful product questions tied to this manual. Each item links to the full Q&A page.

Browse all questions about this manual

Questions & Answers

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

  1. I need some help. In Spanish please!

    Magdalena Silva asks I need some help. In Spanish please!
    Manuals+ clarified question
    Question

    Can you provide help for the Hunter Pro C irrigation controller in Spanish?

    Answer

    Para ayudarle con su controlador Hunter Pro-C, aquí tiene los pasos básicos de programación:

    • Configurar la fecha y hora: Gire el dial a Date/Time. Use los botones + y - para cambiar los valores y el botón > para avanzar.
    • Configurar horas de inicio (Start Times): Gire el dial a Start Times. Establezca la hora en que desea que comience el ciclo de riego.
    • Configurar tiempos de riego (Run Times): Gire el dial a Run Times. Asigne cuántos minutos debe funcionar cada estación (zona).
    • Configurar días de riego (Water Days): Gire el dial a Water Days. Seleccione los días específicos en los que desea regar.
    • Operación Manual: Para activar una estación manualmente, mantenga presionado el botón > durante dos segundos.

    Puede descargar el manual original en PDF desde esta página para ver más detalles técnicos. Si tiene una pregunta específica sobre un error o instalación, por favor háganoslo saber.

  2. Somehow our sprinklers got set to come on twice a day. How do I change that back to once a day, or on the days I choose?

    Barb Johnson asks Somehow our sprinklers got set to come on twice a day. How do I change that back to once a day, or on the days I choose?
    Manuals+ clarified question
    Question

    How do I reduce the number of daily start times and select specific watering days on my Hunter Pro-C controller?

    Answer

    To change your Hunter Pro-C from watering twice a day to once a day, or to select specific days, follow these steps:

    1. Remove Extra Start Times (To stop it from running twice)

    • Turn the dial to the START TIMES position.
    • Check the display for the start time number (e.g., Start Time 1, 2, 3, or 4).
    • Use the PLUS (+) or MINUS (-) buttons to cycle through the start times.
    • If you see a second start time set (e.g., Start Time 2), use the buttons to change the time until it reaches OFF (located between 11:45 PM and 12:00 AM).
    • Ensure only Start Time 1 has a time assigned and all others are set to OFF.

    2. Select Specific Watering Days

    • Turn the dial to the WATER DAYS position.
    • The display will show the days of the week (MO, TU, WE, etc.) with a cursor (a drop or arrow) over them.
    • Use the PLUS (+) button to keep a day active (a drop icon will appear) or the MINUS (-) button to cancel a day (an 'X' or no drop will appear).
    • The cursor will automatically move to the next day as you make your selections.

    Once finished, turn the dial back to the RUN position for the new schedule to take effect.

    1. I am having this same issue. Went through the entire program but everything says 5am/10min per zone/5 zones… noticed this weekend it ran at 5am and again at 7am.

  3. Hello, the screen shows me the information and it is deleted immediately, what can happen with this? Thanks
    Hola la pantalla me muestra la información y se borra de inmediato que puede pasar con esto? Gracias

    Angela Ospina asks <em>Hello, the screen shows me the information and it is deleted immediately, what can happen with this? Thanks<e/em>
    Hola la pantalla me muestra la información y se borra de inmediato que puede pasar con esto? Gracias
    Manuals+ clarified question
    Question

    Why does the screen information disappear immediately after appearing?

    Answer

    If your Hunter Pro-C screen displays information briefly and then disappears, it usually indicates a power supply issue or a problem with the faceplate connection. Please check the following:

    • Check AC Power: Ensure the controller is receiving 120 VAC (or 230 VAC for international models). If the unit is running only on the 9V battery, the display may fade or turn off to save power, especially if the battery is weak. Note that the 9V battery is only intended for programming while the faceplate is removed from the base.
    • Inspect the Ribbon Cable: If you have a modular Pro-C, ensure the ribbon cable connecting the front panel to the back power module is securely plugged in and not damaged.
    • Reset the Controller: You can attempt a soft reset by pressing and holding the PRG button while pressing the RESET button on the back of the faceplate. Release the RESET button first, then the PRG button. The display should show "DONE" if successful.
    • Check the Transformer: Use a multimeter to verify that the transformer is outputting approximately 24-28 VAC. If the voltage is unstable, the display may flicker or cut out.

    If the screen remains blank even with confirmed AC power, the internal CR2032 lithium battery (for the clock) or the faceplate itself may need replacement.

    Note: The Pro-C has non-volatile memory, so your programming should be safe even if the display is currently off.

  4. I am unable to program the 4th water zone on my Hunter Pro-C unit. It was programed but when i added the second day to run the sprinkler the 4th Zone is not there anymore.

    Wentworth Eccles asks I am unable to program the 4th water zone on my Hunter Pro-C unit. It was programed but when i added the second day to run the sprinkler the 4th Zone is not there anymore.
    Manuals+ clarified question
    Question

    Why is Zone 4 missing from my Hunter Pro-C controller after I changed the watering days?

    Answer

    If Zone 4 has disappeared from your Hunter Pro-C controller, it is likely due to one of the following reasons related to how the modular system and programming work:

    • Check the Program (A, B, or C): The Pro-C allows for three independent programs. If you accidentally switched from Program A to Program B or C while setting the second day, Zone 4 might not have a run time assigned in that specific program. Press the PRG button to cycle through A, B, and C and check if the run time for Zone 4 appears in any of them.
    • Module Connection: The Pro-C is a modular controller. If the base module or the expansion module for Zone 4 has a loose connection, the controller may no longer recognize those stations. Turn the dial to OFF, unplug the controller (and remove the battery), then slide the module locking bar to the unlocked position. Firmly reseat the modules and slide the bar back to the locked position before powering back up.
    • Run Time Reset: Ensure that a run time is still assigned to Station 4. Turn the dial to Set Station Run Times and use the Plus (+) or Minus (-) buttons to ensure Zone 4 has minutes assigned. If it is set to "0", it will be skipped during the cycle.
    • Hidden Stations: If the controller was recently reset or the module was bumped, it may need to re-scan the modules. You can perform a "Quick Reset" by holding the Minus (-) and Plus (+) buttons simultaneously for a few seconds until the display clears and then returns to the normal time.

    If the zone still does not appear, ensure the module locking bar is fully engaged, as this is the most common cause for the controller "losing" zones.

  5. I programmed A To run through four zones, when it’s finished it just runs through A again and doesn’t shut off any suggestions

    Dean asks I programmed A To run through four zones, when it’s finished it just runs through A again and doesn’t shut off any suggestions
    Manuals+ clarified question
    Question

    Why does my Hunter Pro-C controller repeat the watering cycle for Program A instead of shutting off?

    Answer

    The most common reason a Hunter Pro-C controller repeats a cycle is that multiple Start Times have been programmed for the same program. On the Pro-C, a single Start Time will automatically run all zones assigned to that program in sequence. If you have set a second, third, or fourth start time, the controller will restart the entire sequence once the first one finishes.

    To fix this, follow these steps:

    1. Turn the dial to the Set Program Start Times position.
    2. Ensure you are on Program A (check the display for the program letter; use the PRG button to toggle if needed).
    3. Use the Plus (+) or Minus (-) buttons to view Start Times 1, 2, 3, and 4.
    4. If Start Times 2, 3, or 4 have a time assigned, they will cause the cycle to repeat. To disable them, navigate to that start time and use the buttons to change the time to OFF (usually found between 11:45 PM and 12:00 AM).
    5. Turn the dial back to Run.

    If the issue persists, ensure you do not have overlapping start times on Programs B or C that might be triggering additional cycles.

    Note: Only one start time is required to run all zones in a program.

    Reference: Hunter Pro-C User Manual, "Setting Program Start Times" section.

  6. Where is the manual for the older Pro-C??

    Jack asks Where is the manual for the older Pro-C??
    Manuals+ clarified question
    Question

    Where can I find the manual for the older Hunter Pro-C irrigation controller models?

    Answer

    The manual for the older Hunter Pro-C (PC Series) modular controller is available on this page. You can access the original PDF versions using the links below:

    If your unit is a legacy model (pre-2004) or you are looking for a specific older revision not covered by these documents, you can also use the Manuals+ Deep Search tool or visit the Hunter Industries website's support section, which maintains an archive of discontinued product manuals.

  7. When we use the manual control to water, it has the correct number of stations (7) that our sprinkler system contains.
    We want to set the program control to water, but we can only view four (4) of the seven (7) stations we have. How can I program the other three stations three missing stations or add them back?

    Carolyn asks When we use the manual control to water, it has the correct number of stations (7) that our sprinkler system contains.
    We want to set the program control to water, but we can only view four (4) of the seven (7) stations we have. How can I program the other three stations three missing stations or add them back?
    Manuals+ clarified question
    Question

    How do I program stations 5, 6, and 7 on my Hunter Pro-C controller when only stations 1-4 are visible in the program settings?

    Answer

    If you can manually operate all 7 stations but cannot see them during programming, it usually means the controller has not yet "recognized" the expansion modules or the run times for those specific stations are currently set to zero.

    To add or view the missing stations (5, 6, and 7) for your automatic schedule, follow these steps:

    • Check Run Times: Turn the dial to the RUN TIMES position. Use the plus (+) or minus (-) buttons to navigate through the stations. If the display stops at station 4, it may be because the controller needs a reset to recognize the modules.
    • Module Recognition (Power Cycle): The Pro-C is a modular controller. If you recently added modules or if they aren't showing up, turn the dial to RUN, then unplug the controller from power (or remove the ribbon cable to the front panel) for 30 seconds and plug it back in. This forces the controller to scan the slots and recognize stations 5 through 7.
    • Verify Module Seating: Ensure the expansion modules in the back of the controller are slid firmly into the locked position. If a module is loose, the controller will only display the base 4 stations.
    • Programming: Once the controller recognizes the modules, turn the dial to RUN TIMES and use the Right Arrow button to advance past station 4. You should then see station 5, 6, and 7, where you can use the plus (+) button to add watering minutes to each.

    Note: If the stations work in manual mode, the modules are physically connected, so a quick power cycle or checking the RUN TIMES dial position specifically is the most likely fix.

  8. We had an electrical storm last week that caused our sprinkler system to come on. We could not stop it without pulling the electrical cord from the socket. Now were having trouble reprograming the system. Can you help?

    Robert J Brauch asks We had an electrical storm last week that caused our sprinkler system to come on. We could not stop it without pulling the electrical cord from the socket. Now were having trouble reprograming the system. Can you help?
    Manuals+ clarified question
    Question

    How do I reprogram the Hunter Pro-C controller after a power surge or electrical storm?

    Answer

    Electrical storms can sometimes cause the controller to behave erratically. Since you had to pull the plug to stop the system, it is recommended to perform a Full Reset before attempting to reprogram. This clears the memory and ensures no 'glitch' data remains.

    To Reset the Controller:

    1. Press and hold the PRG button.
    2. While holding the button, press and release the RESET button (located in the wiring compartment or on the back of the faceplate).
    3. Continue holding the PRG button until the display shows 'DONE'.

    Basic Reprogramming Steps:

    • Set Date and Time: Turn the dial to Current Time/Day. Use the + and - buttons to change the flashing value, and the Right Arrow to move to the next setting.
    • Set Start Times: Turn the dial to Start Times. Ensure you only have one start time for Program A (unless you want the cycle to repeat). Set others to 'OFF'.
    • Set Run Times: Turn the dial to Run Times. Assign the number of minutes for each station (zone).
    • Set Water Days: Turn the dial to Water Days. Use the + button to keep a day (raindrop icon) or the - button to skip it (crossed-out raindrop).

    Finally, turn the dial back to RUN. If the system still fails to respond or stations stay on constantly, the electrical storm may have damaged the internal solenoid valves or the controller's power module, which might require professional inspection.

  9. Is there a way to reset the entire program, so I can start over? I thought I had corrected everything that was mistakenly set, and now it has started running on off days.

    Peg Tichenor asks Is there a way to reset the entire program, so I can start over? I thought I had corrected everything that was mistakenly set, and now it has started running on off days.
    Manuals+ clarified question
    Question

    How do I perform a full factory reset on the Hunter Pro-C controller to clear all programming?

    Answer

    To clear all programmed data and return the Hunter Pro-C controller to its original factory defaults, follow these steps for a Full Reset:

    1. Press and hold down the PRG and Minus (-) buttons simultaneously.
    2. While holding these buttons, press and release the RESET button (located in the wiring compartment or on the back of the faceplate).
    3. Continue holding the PRG and Minus (-) buttons until the display shows "DONE".
    4. Release the buttons. The display should now show 12:00 AM, indicating the controller has been reset and is ready for new programming.

    Note: This will erase all start times, run times, and water days across all programs (A, B, and C). If your controller is running on "off days," also ensure you check that you haven't accidentally set an Odd/Even or Interval schedule instead of a 7-day calendar schedule.

  10. I’m having trouble with the rain sensor for a Hunter Pro-C controller. Should the button be up covering “bypass” or down leaving “active” covered.

    Thanks

    Bob Mollica asks I'm having trouble with the rain sensor for a Hunter Pro-C controller. Should the button be up covering "bypass" or down leaving "active" covered.

    Thanks

    Manuals+ clarified question
    Question

    How should the rain sensor bypass switch be positioned on the Hunter Pro-C controller?

    Answer

    To ensure your rain sensor is functioning and able to stop watering during rain, the switch should be in the down position, which leaves the "ACTIVE" label visible (or uncovered).

    If you want the controller to ignore the sensor and water even when it is raining, you should slide the switch up to the "BYPASS" position. When the switch is in the Active position and the sensor is wet, the display will typically show "OFF" or a sensor icon to indicate that watering is being suspended.

  11. 现在 Hunter Pro-C 装置上编程都停了,不工作,应该怎么调节

    Summer asks 现在 Hunter Pro-C 装置上编程都停了,不工作,应该怎么调节
    Manuals+ clarified question
    Question

    The Hunter Pro-C programming has stopped and it is not working. How should I adjust it?

    Answer

    If your Hunter Pro-C controller has stopped working or the programming is not initiating, please check the following steps to troubleshoot and adjust the settings:

    • Check the Dial Position: Ensure the dial is set to the RUN position. If the dial is set to SYSTEM OFF, the controller will not run any programs.
    • Verify Start Times: Turn the dial to START TIMES. Ensure that Program A, B, or C has at least one start time assigned. If all start times show "OFF," the system will not trigger.
    • Check Run Times: Turn the dial to RUN TIMES. Each station (zone) you want to water must have a run time (e.g., 10 minutes) assigned. If they are all set to 0, the controller will skip them.
    • Water Days: Turn the dial to WATER DAYS. Ensure that the specific days you want to water are active (indicated by a water drop icon) and not crossed out.
    • Check for Rain Sensor: If you have a rain sensor installed, it may be active and preventing the system from running. You can bypass it by sliding the sensor switch on the controller to the BYPASS position to see if the system starts.
    • Power Check: If the display is blank, check the circuit breaker and ensure the transformer is plugged in. The Pro-C uses non-volatile memory, so your program should be saved even if power was lost, but it requires AC power to operate the valves.

    To test the system immediately, you can turn the dial to MANUAL-SINGLE STATION, select a station, and turn the dial back to RUN to see if the valves activate.

Ask a Question