hager ADC932R Residual Current Operated Circuit Breaker

hager-ADC932R-Residual-Current-Operated-Circuit-Breaker-product

Specifications

  • Product Name: Residual current operated circuit-breaker RCBO with switched neutral
  • Current Range: 6 to 32 A
  • Electrical Connection: Top or bottom, bi-directional device
  • Mounting: DIN rail mount & Invicta panel board (excludingUK market)

This device is to be installed only by a professional electrician fitter according to local applicable installation standards. Do not plug in or unplug this product when it is live.

Residual current operated circuit-breaker RCBO with switched neutral 6 to 32 A

Electrical connection

hager-ADC932R-Residual-Current-Operated-Circuit-Breaker- (1)

Easy dismounting with the plastic DIN rail clip

hager-ADC932R-Residual-Current-Operated-Circuit-Breaker- (2)

Locking device for handle MZN175

hager-ADC932R-Residual-Current-Operated-Circuit-Breaker- (3)

TESThager-ADC932R-Residual-Current-Operated-Circuit-Breaker- (4)

Information

EVCS Guidance notes
ADC932R 32 A RCBO

  • Where a ADC932R RCBO is used to supply a 7.5 Kwh car charger 10 mm2 cable must be used from the RCBO to the installed vehicle charge point.
  • Can only be used in a 6 way or larger enclosure for this application.
  • Guidance Notes for All 100 A Dual RCCB Flush Consumer Units
  • ADC932R 32 A RCBO is not verified in any Flush 100 A Dual RCCB consumer units for the continuous loading of a 7.5 Kwh car charger and MUST not be used.

T +33 (0)3 88 49 50 50 info@hager.com
hager.com – 2023.11.27

FAQ

  • Q: Can this RCBO be used to supply power to a car charger?
    A: Yes, when supplying power to a 7.5 Kwh car charger, ensure to use a 10 mm2 cable from the RCBO to the charge point. The RCBO must be installed in a 6-way or larger enclosure for this application.
  • Q: Can the RCBO be used in a Flush 100 A Dual RCCB consumer unit for a car charger?
    A: No, the ADC932R 32 A RCBO is not verified for use in Flush 100 A Dual RCCB consumer units for continuous loading of a 7.5 Kwh car charger and must not be used for this purpose.

Documents / Resources

hager ADC932R Residual Current Operated Circuit Breaker [pdf] Owner's Manual
ADC932R, ADC932R Residual Current Operated Circuit Breaker, ADC932R, Residual Current Operated Circuit Breaker, Operated Circuit Breaker, Circuit Breaker, Breaker