BAC-12xxxx FlexStat Controllers Sensors
Umarni
BAC-12xxxx FlexStat Controllers Sensors
BAC-12xxxx/13xxxx Series
FlexStat™
Bayani da Aikace-aikace
FlexStat wanda ya lashe lambar yabo shine mai sarrafawa da firikwensin a cikin kunshin guda ɗaya, mai ban sha'awa wanda ke haifar da sassaucin bayani don ƙalubalen sarrafawa na tsaye ko ƙalubalen hanyar sadarwa na BACnet. Gano yanayin zafi daidai yake tare da zaɓin zafi, motsi, da fahimtar CO2. Sauƙaƙan shigarwar shigarwa da saitunan fitarwa da ginanniyar ciki ko shirye-shirye na al'ada suna tabbatar da cewa ana iya biyan buƙatun aikace-aikace iri-iri. Irin waɗannan aikace-aikacen sun haɗa da guda- da multi-stage kunshe-kunshe, naúrar, da tsaga tsarin (ciki har da babban SEER / EER m gudun kunshin kayan aiki), kazalika da masana'anta-cushe da kuma filin amfani da tattalin arziki, ruwa-source da iska zuwa iska famfo zafi, fan nada raka'a, tsakiyar tashar iskar sassa, da makamantansu aikace-aikace.
Bugu da ƙari, ɗakin karatu na kan allo na shirye-shirye yana ba da izinin ƙirar ƙira ɗaya don daidaitawa da sauri don aikace-aikacen sarrafa HVAC da yawa. Don haka, “girma ɗaya ɗaya ya dace da duka” ƙirar FlexStat na iya maye gurbin ƙirar masu fafatawa da yawa.
BAC-120163CW guda ɗaya, don misaliample, za a iya tsara su cikin sauri don kowane ɗayan waɗannan zaɓuɓɓukan aikace-aikacen:
◆ Na'urar sarrafa iska, tare da dumama da sanyaya bawul, kuma tare da zaɓin tattalin arziki, dehumidification, da/ko matsayin fan.
◆ Fan coil unit, 2-pipe ko 4-pipe, proportionally or 2-position valves, tare da dehumidification na zaɓi (w/ 4-bututu zaɓi) da / ko fan matsayi
◆ Naúrar famfo mai zafi, tare da kwampreso har biyutages, kuma tare da zaɓin ƙarin zafi, zafi na gaggawa, dehumidification, da/ko matsayin fan
◆ Rufin saman, tare da har zuwa H/C guda biyutages, kuma tare da na zaɓin tattalin arziƙi, rage humidification, da/ko matsayin fan
FlexStats kuma yana ba da damar tsara daidaitaccen ɗakin karatu na jeri ta amfani da kayan aikin KMC (KMC Connect, KMC Converge, ko TotalControl). Wannan yana bawa ɗan kwangilar shigar KMC mai izini na gida damar daidaita daidaitaccen ɗakin karatu zuwa buƙatun rukunin yanar gizo na musamman da takamaiman buƙatun wani aiki.
BACnet akan sadarwar MS/TP daidai ne. Sifofin “E”, tare da jack RJ-45, suna ƙara BACnet akan Ethernet, BACnet akan IP, da BACnet akan IP azaman Na'urar Waje (don sadarwa a cikin Intanet).
Siffofin
Interface da Aiki
◆ menu na harshen Ingilishi-mai amfani mai amfani (babu lambobi masu ɓoye) akan pixel 64 x 128, nunin ɗigo-matrix LCD tare da maɓallin 5 don zaɓin bayanai da shigarwa.
◆ Zaɓuɓɓukan nuni da yawa sun haɗa da madaidaicin nunin zafin jiki da za'a iya zaɓa, canjin digiri F/C, ƙimar jujjuyawar, nunin faifai, yanayin baƙi, da yanayin kulle.
◆ Ginawa, dakunan gwaje-gwajen masana'anta na tsarin sarrafa aikace-aikacen daidaitacce
◆ Integral makamashi management iko tare da ganiya farawa, deadband dumama da sanyaya setpoints, da sauran ci-gaba fasali don tabbatar da ta'aziyya yayin da maximizing makamashi tanadi.
◆ Za a iya tsara jadawalai a sauƙaƙe ta kowane mako (Litinin – Rana), kwanakin mako (Litinin – Juma'a), ƙarshen mako (Asabar – Lahadi), ranaku ɗaya, da/ko hutu; Kunnawa/Kashe shida da lokacin dumama da sanyaya masu zaman kansu suna samuwa kowace rana
◆ Matakai uku na hanyar samun kariya ta kalmar sirri (mai amfani / mai aiki / mai gudanarwa) suna hana rushewar aiki da daidaitawa - da yanayin baƙo da Yanayin Mutuwar Mai amfani da Kulle yana ba da ƙarin tamper juriya
◆ Haɗin zafin jiki da zafi na zaɓi, motsi, da/ko na'urori masu auna firikwensin CO2
◆ Duk samfuran suna da madadin ƙarfin sa'o'i 72 (capacitor) da agogon lokaci na gaske don aiki tare lokacin cibiyar sadarwa ko cikakken aiki kadai.
◆ Model suna maye gurbin yawancin Viconics da sauran samfuran masu fafatawa
Abubuwan shigarwa
◆ Shida bayanan analog don ƙarin na'urori masu auna firikwensin waje masu daidaitawa, kamar zafin jiki mai nisa (tare da matsakaici, mafi girma, da zaɓi mafi ƙasƙanci), CO2 mai nisa, OAT,
MAT, DAT, yanayin samar da ruwa, matsayin fan, da sauran na'urori masu auna firikwensin
Abubuwan shigarwa suna karɓar daidaitattun masana'antu 10K ohm (Nau'in II ko III) na'urori masu auna zafin jiki, busassun lambobin sadarwa, ko 0-12 VDC masu firikwensin aiki
◆ Input overvoltage kariya (24 VAC, ci gaba)
◆ Canjin analog-zuwa-dijital 12-bit akan abubuwan shiga
Abubuwan da aka fitar
◆ Abubuwan fitarwa tara, analog da binary (relays)
◆ Kowane samfurin analog na gajeriyar kewayawa mai iya tuƙi har zuwa 20mA (a 0-12 VDC)
◆ Relays na NO, SPST (Form “A”) yana ɗaukar 1 A max. ko wace gudu ko 1.5 A kowane banki na relays 3 (relays 1–3 da 4–6) @ 24 VAC/VDC
◆ 8-bit PWM juzu'in dijital-zuwa-analog akan abubuwan samarwa
Shigarwa
◆ Akwatin baya yana hawa akan madaidaicin 2 x 4-inch bango mai amfani mai amfani (ko, tare da adaftar HMO-10000, a kwance ko 4 x 4 akwati mai amfani), kuma an adana murfin zuwa farantin baya ta hanyar ɓoye hex guda biyu.
◆ Zane guda biyu yana samar da wayoyi da shigarwa cikin sauƙi (duba Girma da Masu Haɗi a shafi na 9)
Haɗin kai
◆ Screw tubalan, girman waya 14-22 AWG, don shigarwar, abubuwan fitarwa, iko, da hanyar sadarwa na MS/TP
◆ Sifofin “E” suna ƙara jack RJ-45
◆ Tashar bayanai EIA-485 mai fil huɗu a ƙarƙashin shari'ar tana ba da damar haɗin kwamfuta mai sauƙi na ɗan lokaci zuwa hanyar sadarwa ta BACnet da Ka'idoji.
◆ Haɗin kai-da-tsara BACnet MS/TP LAN sadarwar cibiyar sadarwa akan duk samfura (tare da ƙimar baud mai daidaitawa daga 9600 zuwa 76.8K baud)
◆ “E” nau'ikan suna ƙara BACnet akan Ethernet, BACnet akan IP, da BACnet akan IP azaman Na'urar Waje.
Haɗuwa ko wuce ƙayyadaddun bayanan BACnet AAC a cikin ka'idar ANSI/ASHRAE BACnet 135-2008
Daidaituwa
I/O
◆ Har zuwa abubuwan shigar da analog guda 10 (IN1 shine zafin jiki na sarari, IN2-IN4 da IN7-IN9 sune abubuwan 0-12 VDC, IN5 an tanada don zafi, IN6 an tanada don gano motsi, IN10 an tanada don CO2)
◆ Har zuwa 9 abubuwan fitarwa na analog ko binary
Daraja
◆ 150 abubuwan darajar analog
◆ Abubuwan darajar binary 100
◆ Abubuwa 40 masu ƙima na jihohi (tare da jihohi 16 kowace)
Shirin da sarrafawa
◆ 20 PID madauki abubuwa
◆ Abubuwa 10 na shirye-shiryen (ya ƙunshi ɗakin karatu na shirye-shiryen da aka gina 5 da kuma shirye-shiryen Control Basic na musamman a cikin sauran abubuwan shirin 5 ana iya yin su ta hanyar KMC Connect, KMC Converge, ko TotalControl)
Jadawalai da abubuwan da ke faruwa
◆ 2 tsara abubuwa
◆ Abun kalanda 1
◆ 8 abubuwa masu tasowa, kowannensu yana riƙe da 256 samples
Ƙararrawa da abubuwan da suka faru
◆ 5 abubuwa ajin sanarwa (ƙarararrawa/taro) abubuwa
◆ Abubuwa 10 na shiga taron
Samfura
Idan aikace-aikacen ku:
◆ FCU (Fan Coil Unit) ko Kunshin Rukunin, AHU (Sashin Kula da Jirgin Sama), ko RTU (Sashin Babban Rufin) - duba duk samfuran
◆ HPU (Sashin famfo mai zafi) - duba samfuran BAC-1xxx63CW kawai
Don ƙarin cikakkun bayanai, duba Zaɓin Aikace-aikacen/Model
Jagora a shafi na 4. Duba kuma FlexStat Catalog
Kari da Jagorar Zaɓi.
Samfurin* | Fitowa** | Sensors na zaɓi *** | Aikace-aikace na yau da kullun |
BA-1-BA2Samfuran xxxx (misali, BAC-120036CW) daidai suke kuma ba su da firikwensin CO2. BAC-13Samfuran xxxx suna da na'urori masu auna firikwensin CO2 don ƙara isar da iskar buƙatu zuwa aikace-aikacen da ke ƙasa. DCV yana samuwa ne kawai lokacin amfani da aikace-aikacen AHU, RTU, ko HPU tare da zaɓin mai daidaita tattalin arziki. Duba Ƙididdiga, Samfuran CO2 kawai a shafi na 6 don ƙarin bayani. | |||
Saukewa: BAC-1x0036CW | 3 Relays da 6 Abubuwan Analog |
Babu | • 1H/1C, fan, da 6 na duniya • 3-gudun fan, 2- ko 4-bututu FCUs tare da modulating bawuloli • Babban tashar AHUs tare da daidaitawa / 1/2 Heat / Cool • Fitowar fan mai saurin canzawa • Single-stage aikace-aikace |
Saukewa: BAC-1x0136CW | Humidity**** | • Daidai da BAC-1x0036CW • Jeri dehumidification • Jeren humidification (AHU ko 4-bututu FCU) |
|
Saukewa: BAC-1x1036CW | Motsi / Mazauna | • Daidai da BAC-1x0036CW • Aiki na tushen zama |
|
Saukewa: BAC-1x1136CW | Humidity da Motsi / Mazauni**** | • Daidai da BAC-1x0136CW • Aiki na tushen zama |
|
Saukewa: BAC-1x0063CW | 6 Relays da Abubuwan Analog guda 3 | Babu | • 1 ko 2 H da 1 ko 2 C, fan • Multi-stage kunshin ko tsaga tsarin • Multi-stage zafi famfo tare da ko ba tare da masana'anta-kunshe tattalin arziki • Tsakiyar tashar AHUs tare da daidaita zafi/Cool • 3-gudun fan, 2- ko 4-bututu FCUs tare da modulating ko 2-wuri bawul |
Saukewa: BAC-1x0163CW | Humidity**** | • Daidai da BAC-1x0063CW • Jeri dehumidification (AHU, 4-bututu FCU, ko RTU) |
|
Saukewa: BAC-1x1063CW | Motsi / Mazauna | • Daidai da BAC-1x0063CW • Aiki na tushen zama |
|
Saukewa: BAC-1x1163CW | Humidity da Motsi / Mazauni**** | • Daidai da BAC-1x0163CW • Aiki na tushen zama |
|
*Daidaitaccen launi fari ne. Don yin odar zaɓin launin almond mai haske, cire “W” a ƙarshen lambar ƙirar(misali, BAC-121163C maimakon BAC-121163CW). Don yin odar sigar IP, ƙara E bayan C (misali, BAC-121163CEW). Duk samfuran suna da agogo na ainihi. **Analog fitarwa samar da 0-12 VDC @ 20 mA matsakaicin, kuma relays ɗauka 1 A max. ta hanyar gudu ko 1.5 A kowane banki na 3 relays (relays 1–3, 4–6, da 7–9) @ 24 VAC/VDC. *** Duk samfuran suna da na'ura mai sarrafa 32-bit, firikwensin zafin jiki na ciki, da analog 6 abubuwan shiga. Duk samfura suna da zaɓin fitarwar yanayin zafin iska / yanayin yanayin da yanayin yanayin fan. Na'urori masu auna firikwensin zaɓi sun haɗa da zafi, motsi, da CO2. ****A cikin samfura tare da na'urori masu auna firikwensin CO2, na'urori masu zafi sun zo daidai. |
Jagorar Zaɓin Aikace-aikace/Model
Aikace-aikace da Zabuka | FlexStat Model | |||||||
6 Relays da Abubuwan Analog guda 3 | 3 Relays da Abubuwan Analog guda 6 | |||||||
Saukewa: BAC-1x0063CW | Saukewa: BAC-1x0163CW (+Humidity) |
Saukewa: BAC-1x1063CW (+Motion) |
Saukewa: BAC-1x1163CW (+Humidity/Motion) |
Saukewa: BAC-1x0036CW |
Saukewa: BAC-1x0136CW (+Humidity) |
Saukewa: BAC-1x1036CW (+Motion) |
Saukewa: BAC-1x1136CW (+Humidity/Motion) |
|
Rukunin Kunshin (Sashin Kula da iska da Babban Rufi) | ||||||||
1 Zafi da 1 Sanyi | ![]() |
![]() |
![]() |
![]() |
||||
1 ko 2 Heat da 1 ko 2 Cool (a cikin BAC-1xxx63 RTU Menu Kawai) | RTU | RTU | RTU | RTU | ||||
1 ko 2 Heat da Modulating Cool | ![]() |
![]() |
![]() |
![]() |
||||
Modulating Heat da 1 ko 2 Cool | ![]() |
![]() |
![]() |
![]() |
||||
Modulating Heat da Modulating Cool (a cikin Menu AHU Kawai) | AHU | AHU | AHU | AHU | ![]() |
![]() |
![]() |
![]() |
Fita Waje Air Damper, Modulating | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Fita Waje Air Damper, Matsayi 2 (a cikin Menu na RTU kawai) | RTU | RTU | RTU | RTU | ![]() |
![]() |
![]() |
![]() |
Fita Sarrafa Gudun Fan | ![]() |
![]() |
![]() |
![]() |
||||
Fita Dehumidification | ![]() |
![]() |
![]() |
![]() |
||||
Fita Humidifier | ![]() |
![]() |
||||||
Fita Sensor Motsi / Mazauni | ![]() |
![]() |
![]() |
![]() |
![]() |
|||
Fita Sensor CO2 tare da DCV (Hanyar Kula da Buƙatun) | BA-1-BA3xxxx | |||||||
Fita Sadarwar Sadarwar IP/Ethernet BACnet | Ƙara E zuwa lambar ƙirar: BAC-1xxxxxCEx (duba Model Code) | |||||||
FCU (Fan Coil Unit) | Tare da fan 3-gudun | |||||||
2 Bututu, Modulating | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
2 Bututu, 2 Matsayi | ![]() |
![]() |
![]() |
![]() |
||||
4 Bututu, Modulating | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
4 Bututu, 2 Matsayi | ![]() |
![]() |
![]() |
![]() |
||||
Fita Dehumidification (bututu 4 kawai) | ![]() |
![]() |
![]() |
![]() |
||||
Fita Humidifier (bututu 4 kawai) | ![]() |
![]() |
||||||
Fita Sensor Motsi / Mazauni | ![]() |
![]() |
![]() |
![]() |
||||
Fita Sensor CO2 tare da DCV (Hanyar Kula da Buƙatun) | DCV N/A don aikace-aikacen FCU, amma matakan CO2 har yanzu suna nunawa | |||||||
Fita Sadarwar Sadarwar IP/Ethernet BACnet | Ƙara E zuwa lambar ƙirar: BAC-1xxxxxCEx (duba Model Code) | |||||||
HPU (Na'urar Pump Heat) | 1 ko 2 compressors tare da karin taimako da zafi na gaggawa | |||||||
Fita Waje Air Damper, Modulating | ![]() |
![]() |
![]() |
![]() |
N/A |
|||
Fita Dehumidification | ![]() |
![]() |
||||||
Fita Sensor Motsi / Mazauni | ![]() |
![]() |
||||||
Fita Sensor CO2 tare da DCV (Hanyar Kula da Buƙatun) | BA-1-BA3xxxx | |||||||
Fita Sadarwar Sadarwar IP/Ethernet BACnet | Ƙara E zuwa lambar ƙirar: BAC-1xxxxxCEx (duba Model Code) | |||||||
NOTE: Duk samfura suna da agogo na ainihi (duba Lambobin Samfura). A kan samfura tare da firikwensin CO2, firikwensin zafi daidai yake kuma Buƙatar Kula da iska yana samuwa kawai lokacin amfani da aikace-aikacen AHU, RTU, ko HPU tare da zaɓin mai daidaita tattalin arziƙi. BAC-12xxxxx ba shi da firikwensin CO2. Samfura Lambar domin BAC-1xmhra CEW: BAC = Na'urar BACnet 1 = Jerin Samfura x = CO2 Sensor (3) ko Babu (2) m = Sensor Motion (1) ko Babu (0) h = Sensor Humidity (1) ko Babu (0) W = Farin Launi (babu W = almond mai haske) r = Adadin abubuwan da aka fitar (3 ko 6 misali, ko 5 relays & triac 1) a = Yawan Abubuwan Analog (3 ko 6) C = Real-Time Agogo (RTC misali akan duk samfura) E = Zaɓin Sadarwar IP/Ethernet (babu E = MS/TP kawai) |
NOTE: Duba kuma Samfura a shafi na 3. Don cikakkun bayanai game da zaɓin samfurin CO2, duba Ƙayyadaddun bayanai, CO2 Model kawai a shafi na 6. Duba kuma Ƙarin Kasidar FlexStat da Jagorar Zaɓi.
Ƙayyadaddun bayanai, Gabaɗaya
Ƙara Voltage | 24 VAC (+20%/-10%), Class 2 kawai |
Ƙarfin Ƙarfafawa | 13 VA (ba a haɗa da relays ba) |
Sakamakon (3/6 ko 6/3) | Abubuwan da aka fitar na binary (NO, SPST, Form “A” relays) suna ɗaukar 1 A max. ko wace gudu ko jimlar 1.5 A a kowane banki na relays 3 (relays 1–3 da 4–6) @ 24 VAC/VDC Abubuwan Analog suna samar da 0-12 VDC, matsakaicin 20mA |
Abubuwan Shiga (6) | Analog 0-12 VDC (ayyukan aiki, lambobin sadarwa, 10K thermistor) |
Haɗin kai | Waya clamp nau'in tubalan tasha; 14–22 AWG, Tagulla-Filin Hudu EIA-485 (Fita.) Jakin Ethernet mai fil takwas |
Nunawa | 64 x 128 pixel dot matrix LCD |
Kayan Harka | Farar (misali) ko filasta mai kare harshen almond mai haske |
Girma* | 5.551 x 4.192 x 1.125 inci (141 x 106 x 28.6 mm) |
Nauyi* | 0.48 laba. (Kilogram 0.22) |
Amincewa | |
UL | UL 916 Kayan Gudanar da Makamashi da aka jera |
BTL | BACnet Testing Laboratory jera a matsayin Advanced Application Controller (B-AAC) |
FCC | FCC Class B, Sashe na 15, Sashin B kuma ya dace da ICES-003 Class B na Kanada |
**Wannan na'urar ta bi sashe na 15 na Dokokin FCC. Aiki yana ƙarƙashin sharuɗɗa biyu masu zuwa: (1) Wannan na'urar bazai haifar da tsangwama mai cutarwa ba, kuma (2) dole ne wannan na'urar ta karɓi duk wani tsangwama da aka karɓa, gami da tsangwama wanda zai iya haifar da aiki maras so.
Sensor Humidity (na zaɓi na ciki)
Nau'in Sensor | CMOS |
Rage | 0 zuwa 100% RH |
Daidaitacce @ 25 ° C | ± 2% RH (10 zuwa 90% RH) |
Lokacin Amsa | Kasa da ko daidai da daƙiƙa 4 |
Sensor Zazzabi (ba tare da firikwensin zafi ba)
Nau'in Sensor | Thermistor, Nau'in II |
Daidaito | ±0.36°F (±0.2°C) |
Juriya | 10,000 ohms a 77°F (25°C) |
Range Aiki | 48 zuwa 96°F (8.8 zuwa 35.5° C) |
Sensor Zazzabi (tare da firikwensin zafi)
Nau'in Sensor | CMOS |
Daidaito | ±0.9°F (± 0.5°C) biya diyya daga 40 zuwa 104°F (4.4 zuwa 40°C) |
Range Aiki | 36 zuwa 120°F (2.2 zuwa 48.8° C) |
Iyakokin Muhalli*
Aiki | 34 zuwa 125°F (1.1 zuwa 51.6° C) |
Jirgin ruwa | -22 zuwa 140F (-30 zuwa 60° C) |
Danshi | 0 zuwa 95% RH (ba mai haɗawa) |
Garanti | 5 shekaru (daga mfg. lambar kwanan wata) |
* ABIN LURA: Ban da ƙirar firikwensin CO2-duba shafi na gaba don waɗannan ƙayyadaddun bayanai.
Ƙayyadaddun bayanai, Sensor Motion
Sensor Motion (Opt.) Infrared mai wucewa tare da kusan. Tsawon mita 10 (ƙafa 32.8) (don cikakkun bayanai game da aiki na firikwensin motsi, duba Jagorar Aikace-aikacen FlexStat)
Ayyukan Gano Sensor Motsi/Mazauni
Ƙayyadaddun bayanai, CO2 Model Kawai
Girma a Inci (mm)
Girma | 5.551 x 5.192 x 1.437 inci (141 x 132 x 36.5 mm) |
Nauyi | 0.5 laba. (Kilogram 0.28) |
Iyakokin Muhalli
Aiki | 34 zuwa 122°F (1.1 zuwa 50° C) |
Amincewa | FCC Class A, Sashe na 15, Sashi na B kuma ya dace da Kanada ICES-003 Class A |
NOTE: Duba shafin da ya gabata don ƙayyadaddun bayanai na gama gari tare da wasu ƙira.
NOTE: Ba a yarda da samfuran CO2 don aikace-aikacen zama ba.
CO2 Sensor | BAC-13xxx |
Aikace-aikace | Don yankuna masu shagaltarsu/lokacin da ba a mamaye ba* |
Hanya | Infrared Non Dispersive Infrared (NDIR), tare da ABC Logic* |
Daidaitawa | Yana daidaita kansa sama da makonni da yawa* |
Halin Rayuwa na Sensor | shekaru 15 |
Ma'auni Range | 400 zuwa 2000 ppm |
Daidaito (a yanayin zafin aiki mara kyau) | ± 35 ppm @ 500 ppm, ± 60 ppm @ 800 ppm, ± 75 ppm @ 1000 ppm, ± 90 ppm @ 1200 ppm |
Gyaran Matsayi | Ana iya daidaitawa daga ƙafa 0 zuwa 32,000 |
Dogaran Matsi | 0.135 na karatun kowace mm Hg |
Dogaro da Zazzabi | 0.2% FS (cikakken ma'auni) kowace °C |
Kwanciyar hankali | <2% na FS akan rayuwar firikwensin |
Lokacin Amsa | < Minti 2 don 90% canjin mataki na yau da kullun |
Lokacin Dumi | < Minti 2 (aiki) da mintuna 10 (mafi girman daidaito) |
Jerin BAC-13xxxx yana amfani da Ma'anar Calibration na Bayarwa ta atomatik, ko ABC Logic, wata dabarar daidaitawa ta haƙƙin mallaka wacce aka ƙera don amfani da ita a aikace-aikace inda ƙima za ta ragu zuwa yanayin yanayi (kimanin 400 ppm) aƙalla sau uku a cikin kwanaki 14, yawanci a cikin lokutan da ba kowa. Tare da kunna ABC Logic, firikwensin zai yawanci isa daidaitaccen aiki bayan sa'o'i 25 na ci gaba da aiki idan an fallasa shi zuwa matakan tunani na yanayi a 400 ± 10 ppm CO2. Na'urar firikwensin zai kula da ƙayyadaddun ƙayyadaddun bayanai tare da kunna ABC Logic, idan aka ba shi aƙalla sau huɗu a cikin kwanaki 21 da aka fallasa zuwa ƙimar tunani kuma wannan ƙimar ita ce mafi ƙarancin maida hankali ga abin da firikwensin ya fallasa. ABC Logic yana buƙatar ci gaba da aiki na firikwensin na tsawon lokaci na akalla sa'o'i 24.
NOTE: Jerin BAC-13xxxx, tare da ABC Logic, an ba da izini don biyan CA Title 24, Sashe na 121 (c), da kuma ƙaramin sakin layi na 4.F wanda ya ƙayyade daidaito a cikin haƙuri don ƙarancin shekaru 5 ba tare da sakewa ba kuma cewa gazawar firikwensin da aka gano zai sa mai sarrafawa ya ɗauki matakin gyara daidai.
NOTE: Duba kuma sashin Buƙatar Kula da iska (DCV) akan shafi na gaba.
Bukatar Kula da iska (DCV)
Lokacin amfani da aikace-aikace tare da zaɓin mai daidaita tattalin arziƙi, nau'ikan daidaitawar isar da iska ta buƙatu guda uku (DCV) akwai:
◆ Basic — Yana ba da sauƙin DCV, daidaita iska ta waje damper a cikin amsa kai tsaye zuwa matakin CO2 na yanzu dangane da madaidaicin sa. Basic DCV ya fi ƙarfin ƙarfi
inganci fiye da babu DCV kwata-kwata, yayin da yake kiyaye isasshen IAQ (Indoor Air Indoor). Ita ce hanya mafi sauƙi ta DCV don daidaitawa. Koyaya, inda VOCs, radon, ko wasu gurɓataccen abu suka zama wuce gona da iri yayin lokutan da ba a shagaltar da su (ba tare da samun iska ba), ana ba da shawarar FlexStat's Standard ko Advanced DCV sanyi.
◆ Standard—Lokacin da aka daidaita saitunan BAC-13xxxx da kyau, wannan ya bi CA Title 24, Sashe na 121(c). Wannan kuma zai shafi BAC-12xxxx da aka tsara da kyau tare da firikwensin SAE-10xx CO2 mai nisa. Stan dard DCV, a ƙarƙashin yawancin yanayi, ba shi da ɗan ƙarancin kuzari fiye da Basic, amma yana haɓaka IAQ.
◆ Na ci gaba-Lokacin da aka daidaita saitunan da kyau, wannan saitin ya dace da CA Title 24, Sashe na 121 (c) da ASHRAE Standard 62.1-2007 kuma yana bin jagororin PKudin hannun jari Ortland Energy Conservation, Inc. (PECI).
Kodayake Advanced DCV shine mafi rikitarwa don daidaitawa, ya fi ƙarfin kuzari fiye da Standard yayin da yake haɓaka IAQ.
Kodayake BAC-12xxxx FlexStats ba su da ginanniyar firikwensin CO2, har yanzu suna da jerin sarrafa DCV. Lokacin da aka kunna DCV a cikin waɗannan samfuran, ana ɗauka IN9 za a haɗa shi da firikwensin KMC SAE-10xx CO2 na waje. BAC-13xxxx FlexStats kuma suna da zaɓi na firikwensin waje, kuma idan aka yi amfani da su, za a yi amfani da mafi girman karatun biyun (na ciki vs. waje) don sarrafa jerin DCV. Nunin CO2 ppm (lokacin da aka kunna) kuma yana nuna mafi girman matakan biyun.
NOTE: Hotunan Kanfigareshan DCV guda uku a hagu suna nuna bangaren DCV na siginar zuwa iska damper. Dangane da yanayi da tsarin DCV, siginar zuwa dampAna iya sarrafa shi ta Mafi ƙarancin Matsayi, Madaidaicin Tattalin Arziki, ko wasu abubuwan haɗin gwiwa. Ana amfani da matsakaicin ƙimar waɗannan sassa, ba jimlar su ba. (Idan akwai ƙararrawa mara ƙarancin iyaka, duk da haka, waɗannan sigina sun mamaye, kuma dampan rufe.)
NOTE: DCV yana samuwa ne kawai lokacin amfani da aikace-aikacen AHU, RTU, ko HPU tare da zaɓin mai daidaita tattalin arziki. Idan ba tare da wannan saitin ba, DCV ba zai bayyana a menus ba, amma CO2 ppm karatun zai (sai dai idan an kashe shi a cikin menu na Mai amfani) har yanzu yana nunawa a ƙasan dama na nuni.
Hoton da ke ƙasa yana nuna tsohonample na yadda wurin sanyaya da iskan waje dampMatsayin da zai iya sarrafawa da kyau ta hanyar ginanniyar tsarin FlexStat na jadawali, firikwensin motsi (wanda aka saita don jiran aiki da mamaye zama), da firikwensin CO2 (wanda aka saita don Advanced DCV).Don ƙarin cikakkun bayanai game da daidaitawar DCV da aiki, duba Jagoran Aiki na FlexStat kuma Jagorar Aikace-aikacen FlexStat.
Na'urorin haɗi
Damper (OAD/RTD) Masu aiki (Rashin-Safe)
MEP-4552 | 5.6 ft2 max. dampyanki, 45 in-lb., Daidaitawa, 19 VA |
MEP-7552 | 22.5 ft2 max. dampyanki er, 180 in-lb., Daidaitawa, 25 VA |
MEP-7852 | 40 ft2 max. dampyanki er, 320 in-lb., Daidaitawa, 40 VA |
Hawan Hardware
![]() |
![]() |
![]() |
HMO-10000 | A kwance ko 4 x 4 akwatin bango mai amfani da farantin bango don ƙirar BAC12xxxx (ba a buƙata don ƙirar BAC-13xxxx), almond mai haske (an nuna) |
HMO-10000W | HMO-10000 a cikin farin |
Saukewa: HPO-1602 | Maye gurbin farantin baya don samfuran BAC-12xxxx |
Saukewa: HPO-1603 | Maye gurbin farantin baya don ƙirar BAC-13xxxx (an nuna) |
SP-001 | Screwdriver (KMC mai alama) tare da lebur ruwa (na tashoshi) da ƙarshen hex (don rufe sukurori) |
Sadarwar Sadarwar Sadarwar Sadarwa da Firmware
![]() |
![]() |
![]() |
BAC-5051E | BACnet na'ura mai ba da hanya tsakanin hanyoyin sadarwa |
Saukewa: HPO-5551 | Kayan aikin USB technician na'ura mai ba da hanya tsakanin hanyoyin sadarwa |
HTO-1104 | FlexStat kayan haɓaka firmware |
KMD-5567 | Network surge suppressor |
KMD-5575 | Maimaita hanyar sadarwa / mai warewa |
KMD-5624 | Kebul na USB data tashar jiragen ruwa (EIA-485) (FlexStat zuwa kebul na sadarwa) - wanda ya haɗa da KMD-5576 |
Relays (Na waje)
REE-3112 | (HUM) SPDT, 12/24 VDC mai sarrafawa |
Sensors (Na waje)
![]() |
![]() |
CSE-110x | (FST) bambancin matsa lamba na iska |
STE-1402 | (DAT) firikwensin zafin jiki na duct w/8 inch m bincike |
STE-1416 | (MAT) 12 ′ (mai sassauƙa) madaidaicin bututu. firikwensin |
STE-1451 | (OAT) yanayin iska na waje. firikwensin |
STE-6011 | Yanayin sararin samaniya mai nisa. firikwensin |
SAE-10xx | firikwensin CO2 mai nisa, sarari ko bututu |
STE-1454/1455 | (W-TMP) 2 ″ madauri akan zafin ruwa. firikwensin (tare da ko ba tare da yadi ba) |
Transformers, 120 zuwa 24 VAC (TX)
Saukewa: 6311-050 | 50 VA, dual-hub |
Saukewa: 6112-050 | 50 VA, dual-hub |
Bawuloli (Duba / sanyaya / Humidification)
VEB-43xxxBCL | (HUMV/CLV/HTV) Bawul ɗin sarrafawa mara lafiya, w/ MEP-4×52 daidaitaccen ctuator, 20 VA |
Saukewa: VEB-43xxxBCK | (VLV/CLV/HTV) bawul mai sarrafawa w/ MEP4002 daidaitaccen actuator, 4 VA |
VEZ-4xxxxMBx | (VLV/CLV/HTV) bawul mai kula da lafiya, 24 VAC, 9.8 VA |
NOTE: Don cikakkun bayanai, duba takaddun bayanan samfur daban-daban da jagororin shigarwa. Duba kuma Jagorar Aikace-aikacen FlexStat.
Girma da Haɗuwa
NOTE: Zane-zanen yanki biyu yana ba da damar shiga tsakani da ƙarewar wayan filin zuwa farantin baya ba tare da buƙatar FlexStat a rukunin yanar gizon ba - ba da izinin FlexStats ya zama babba-
saita kashe-shari'a kuma toshe cikin faranti na baya na waya a wani lokaci idan ana so.
Kyautar Samfura da Takardu
◆ lambar yabo ta Zinariya a cikin nau'in Networked/BAS na Ƙwararriyar Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Injiniya (Satumba 2010)
◆ Samfurin Zaɓin Editoci a cikin Kayayyakin Ginin Kasuwanci (Oktoba 2010)
◆ Mai nasara a cikin HVAC & Plumbing category na Green Thinker Network's Sustainability 2012 gasar (Afrilu 2012)
◆ Takardun tallafi na FlexStat kuma sun sami lambar yabo ta Kyauta a gasar wallafe-wallafen 2009-2010 wanda Sashen Chicago na Society for Technical Communication (Afrilu 2010) ya dauki nauyinsa.
Sampda Installation
Taimako
Ana samun albarkatu masu nasara don shigarwa, daidaitawa, aikace-aikace, aiki, shirye-shirye, haɓakawa da ƙari da yawa akan Gudanarwar KMC web shafin (www.kmccontrols.com). Don ganin duk akwai files, shiga shafin KMC Partners.
KMC Controls, Inc. girma
19476 Driver Masana'antu
New Paris, IN 46553
574.831.5250
www.kmccontrols.com
info@kmccontrols.com
© 2023 KMC Controls, Inc.
Takardu / Albarkatu
![]() |
KMC SAMUN SAUKI BAC-12xxxx FlexStat Sensors [pdf] Umarni BAC-12xxxx FlexStat Sensors Masu Gudanarwa, BAC-12xxxx |