Fatalwa tana sarrafa Manual mai amfani da faifan maɓalli mara waya ta Axwk
Samfurin Ƙarsheview
ASSEMBLING YOUR KEYPAD IN 3 EASY STEPS
NOTE
Keypad housing must be removed, and two (2) C batteries (not included) need to be installed before programming or mounting the keypad. Installing the batteries requires you to unscrew the bottom two screws and insert the batteries.
UNDERSTANDING NORMAL KEYBOARD BEEPS AND LEDS
FAHIMTA AL'ADA KEYBOARD KWADAYI KUMA LEDS | |
NASARA SHIGA | FAILED ENTRIES |
LEDs will flash ON/OFF each time you press a key, indicating the keypad has accepted each entry | Invalid Pin: LED flashes and buzzer beeps TWIC, E, then goes off. Retry till successful entry |
LED will flash slowly, and the keypad lights will remain on for 30 seconds. If you have entered a valid PIN | Invalid Programming: ALL LEDs and buzzer stay on for 2 seconds, then go off. Retry till successful entry |
- YOUR MASTER PIN #* _____________________ ACCESS PIN # _______________________
- ACCESS PIN 2 # ____________________________ ACCESS PIN 3 # _____________________
- (DO NOT GIVE OUT MASTER PIN!)
GARGADI
Changes or modifications to this unit not expressly approved by the party responsible for Compliance could void the user’s authority to operate the equipment.
NOTE: An gwada wannan kayan aikin kuma an same shi don biyan iyaka don na'urar dijital ta Class B, ƙarƙashin Sashe na 15 na Dokokin FCC. An ƙirƙira waɗannan iyakokin don ba da kariya mai ma'ana daga tsangwama mai cutarwa a cikin shigarwar mazauni. Wannan kayan aiki yana haifarwa, amfani, kuma yana iya haskaka ƙarfin mitar rediyo kuma, idan ba'a shigar da shi ba kuma aka yi amfani da shi bisa ga umarnin, na iya haifar da tsangwama mai cutarwa ga sadarwar rediyo. Duk da haka, babu tabbacin cewa tsangwama ba zai faru a cikin wani shigarwa na musamman ba.
SHIRI
All GHOST CONTROLS® Premium Keypads must be programmed with a 4-digit Master PIN before operating the Gate Opener System so that the safety and security of your system is maintained. The keypad will store up to 20 access pins, including the master access pin.
NOTE: Keypad will remain in programming mode for up to one minute between key presses to allow adequate time to go through each step. If you happen to incorrectly press a key sequence (such as SEND, SEND), then the keypad will immediately drop out of programming mode,e and you will have to start back at Step 1 of that programming sequence.
SETTING UP YOUR MASTER PIN (DO NOT GIVE OUT MASTER PIN!)
YOUR DEFAULT FACTORY MASTER PIN.
REPLACE THE DEFAULT MASTER PIN TO A NEW 4-DIGIT PIN NUMBER (XXXX)
(Keep PIN safe, don’t lose)
EX
TEACHING YOUR REMOTE TO THE KEYPAD
The keypad will not transmit a signal to the gate opener controller until it has learned the unique transmitting code from a programmed working remote transmitter that currently operates your gate opener. The remote teaches the GhostCode to the keypad. Proper positioning of the transmitter to the keypad is critical for this process to work. Please see the diagram and the steps below.
- ENTER MASTER PIN AND THEN 58 ONTHE KEYPAD
- POSITION REMOTE AND KEYPAD (as shown in the diagram)
- PRESS & HOLD THE TRANSMITTER BUTTON THAT OPERATES THE GATE UNTIL THE KEYPAD “LEARNS” THE SIGNAL (SUCCESS = hearing 3 beeps from keypad, pause, 2 beeps)
- GATE SHOULD WORK USING YOUR KEYPAD AND NEW MASTER PIN (XXXX)
ADD AN ACCESS PIN USING YOUR NEW MASTER PIN (XXXX)
Bi a kasa
X= master pin | ?= access pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
ADD A TEMPORARY PIN (this time-based pin will not work after “DD” days).
Bi a kasa
X= master pin | ?= temp pin | (SUCCESS= hearing 3 beeps, pause, 2 beeps)
ADDA USE-BASED TEMPORARY PIN (This use-based pin will not work after “UU” uses)
Bi a kasa
X= master pin | ?= use temp pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
DELETE AN ACCESS PIN (You can no longer use this pin to operate the gate)
Bi a kasa
X= master pin | ?= access pin deleting | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
REPLACE MASTER PIN (do not give out your master pin to allow access).
Bi a kasa
X= master pin | N = new master pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
PROGRAMMING SPECIAL FEATURES (CAN ONLY PROGRAM USING MASTER PIN)
PARTYMODE® (keeps gate open to allow access to property for a set time) When you want to enable PARTYMODE®to keep the gate in the open position and suspend the gate’s auto-close feature (if enabled), the gate opener will beep twice if there is an attempt to close the gate. This is to indicate that PARTYMODE® is enabled; therefore gate cannot be closed. Follow the steps below:
X= master pin | (SUCCESS = hearing 2 beeps)
PARTYMODE SECURETM AND 1KEYTM (use any number key and send the key to operate the gate to allow access). When you want to enable PARTYMODE SECURETM or 1KEYTM, any number ke, and the SEND key will operate the gate without the need to enter an ACCESS pin. The green LED button will stay on when any key is pressed to indicate the keypad is in 1KEYTM mode.
Bi matakan da ke ƙasa.
X = master pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
VACATIONMODE® (keeps gate closed, NO access to property) When you want to enable VACATIONMODE® to keep the gate in the closed position (gate has to be closed to set). GateIt will beep twice if there is an attempt to open the gate. This is to indicate that VACATIONMODE® is enabled, and the gate can not be opened. Follow the steps below:
X= master pin | (SUCCESS = hearing 2 beeps)
JAGORANCIN MAGANCE MATSALAR
JAGORANCIN MAGANCE MATSALAR | |||||
MATSAYI ![]() ![]() ![]() Hasken LED |
|||||
AL'ADA MODE | |||||
KASHE | KASHE | KASHE | KASHE | KASHE | Unit in sleep mode |
1 gajeriyar kiftawa | 1 gajeriyar ƙara | N/A | N/A | N/A | When any key is pressed provides visual and audio feedback |
2 gajeriyar kiftawa | 2 gajeriyar ƙararrawa | N/A | N/A | N/AThe unit | t enters sleep mode after 2 short blinks and beeps |
Kunna na daƙiƙa 2 | Kunna na daƙiƙa 2 | N/A | N/A | N/A | Too many PIN entry attempts. The unit goes to shut-down mode for 1 min. |
N/A | N/A | ON | KASHE | KASHE | ![]() |
N/A |
N/A |
KASHE |
ON |
KASHE |
![]() |
N/A | N/A | KASHE | KASHE | ON | ![]() |
HALIN SHIRIN | |||||
3 gajeriyar kiftawa |
3 gajeriyar ƙararrawa |
3 blinks and stay ON |
3 blinks and stay ON |
3 blinks and stay ON |
Successful initial entry into PROGRAM mode (Program key is pressed while unit is in sleep mode). The unit will automatically return to normal operation after 60 seconds of inactivity. |
1 gajeriyar kiftawa | 1 gajeriyar ƙara | ON | ON | ON | When any key is pressed, to provide visual and audio feedback |
3 short blinks PAUSE
2 gajeriyar kiftawa |
3 short blinks PAUSE
2 gajeriyar kiftawa |
ON during beeping, then OFF | ON during beeping, then OFF | ON during beeping, then OFF | Successfully completed programming sequence |
Kunna na daƙiƙa 2 |
Kunna na daƙiƙa 2 |
ON sai KASHE |
ON sai KASHE |
ON sai KASHE |
Invalid entry during programming mode. Programming is not successful. Unit exits to
aiki na yau da kullun |
FACTORY DEFAULT MEMORY | |||||
3 long blinks PAUSE 2 gajeriyar kiftawa |
3 long blinks PAUSE 2 gajeriyar kiftawa |
3 kyaftawa |
3 kyaftawa |
3 kyaftawa |
The unit’s PIN memory and settings are in Factory Default Mode. No other function is operational until the unit is initialized. Please refer to tthe INGANTA SET-UP section to initialize the unit. |
2 long blinks PAUSE 2 gajeriyar kiftawa |
2 long blinks PAUSE 2 gajeriyar kiftawa |
2 kyaftawa |
2 kyaftawa |
2 The unit’s |
s RF transmitting code is still at factory default (blank). Refer to the LEARN TRANSMITTER section to program a transmitter’s code to the keypad. |
Sauke PDF: Ghost Controls Axwk Wireless Keypad User Manual