ASSEMBLING YOUR KEYPAD IN 3 EASY STEPS

FANAMARIHANA
Keypad housing must be removed, and two (2) C batteries (not included) need to be installed before programming or mounting the keypad. Installing the batteries requires you to unscrew the bottom two screws and insert the batteries.

Ghost Controls-Axwk-Wireless-Keypad-FIG- (2)

UNDERSTANDING NORMAL KEYBOARD BEEPS AND LEDS

hahazoana hevi-javatra ara-dalàna Ohatra BEEPS SY LEDS
MAHOMBY anglisy FAILED ENTRIES
LEDs will flash ON/OFF each time you press a key, indicating the keypad has accepted each entry Invalid Pin: LED flashes and buzzer beeps TWIC, E, then goes off. Retry till successful entry
LED will flash slowly, and the keypad lights will remain on for 30 seconds. If you have entered a valid PIN Invalid Programming: ALL LEDs and buzzer stay on for 2 seconds, then go off. Retry till successful entry
  • YOUR MASTER PIN #* _____________________ ACCESS PIN # _______________________
  • ACCESS PIN 2 # ____________________________ ACCESS PIN 3 # _____________________
  • (DO NOT GIVE OUT MASTER PIN!)

FAMPITANDREMANA
Changes or modifications to this unit not expressly approved by the party responsible for Compliance could void the user’s authority to operate the equipment.
FANAMARIHANA: Ity fitaovana ity dia nosedraina ary hita fa mifanaraka amin'ny fetran'ny fitaovana nomerika Class B, araka ny Fizarana faha-15 amin'ny Fitsipika FCC. Ireo fetra ireo dia natao hanomezana fiarovana ara-drariny amin'ny fitsabahana manimba amin'ny fametrahana trano fonenana. Ity fitaovana ity dia miteraka, mampiasa, ary afaka mampiakatra ny angovon'ny onjam-peo ary, raha tsy apetraka sy ampiasaina araka ny toromarika, dia mety hiteraka fanelingelenana manimba ny fifandraisana amin'ny radio. Na izany aza, tsy misy antoka fa tsy hisy fitsabahana amin'ny fametrahana manokana.

FANDAHARANAGhost Controls-Axwk-Wireless-Keypad-FIG- (3)

All GHOST CONTROLS® Premium Keypads must be programmed with a 4-digit Master PIN before operating the Gate Opener System so that the safety and security of your system is maintained. The keypad will store up to 20 access pins, including the master access pin.
FANAMARIHANA: Keypad will remain in programming mode for up to one minute between key presses to allow adequate time to go through each step. If you happen to incorrectly press a key sequence (such as SEND, SEND), then the keypad will immediately drop out of programming mode,e and you will have to start back at Step 1 of that programming sequence.

SETTING UP YOUR MASTER PIN (DO NOT GIVE OUT MASTER PIN!)Ghost Controls-Axwk-Wireless-Keypad-FIG- (3)
YOUR DEFAULT FACTORY MASTER PIN.
REPLACE THE DEFAULT MASTER PIN TO A NEW 4-DIGIT PIN NUMBER (XXXX)
(Keep PIN safe, don’t lose)

EX

Ghost Controls-Axwk-Wireless-Keypad-FIG- (5)

TEACHING YOUR REMOTE TO THE KEYPAD

The keypad will not transmit a signal to the gate opener controller until it has learned the unique transmitting code from a programmed working remote transmitter that currently operates your gate opener. The remote teaches the GhostCode to the keypad. Proper positioning of the transmitter to the keypad is critical for this process to work. Please see the diagram and the steps below.

  1. ENTER MASTER PIN AND THEN 58 ONTHE  KEYPADGhost Controls-Axwk-Wireless-Keypad-FIG- (6)
  2. POSITION REMOTE AND KEYPAD (as shown in the diagram)Ghost Controls-Axwk-Wireless-Keypad-FIG- (7)
  3. PRESS & HOLD THE TRANSMITTER BUTTON THAT OPERATES THE GATE UNTIL THE KEYPAD “LEARNS” THE SIGNAL (SUCCESS = hearing 3 beeps from keypad, pause, 2 beeps)
  4. GATE SHOULD WORK USING YOUR KEYPAD AND NEW MASTER PIN (XXXX)Ghost Controls-Axwk-Wireless-Keypad-FIG- (8)

ADD AN ACCESS PIN USING YOUR NEW MASTER PIN (XXXX)

Ghost Controls-Axwk-Wireless-Keypad-FIG- (9)

Araho eto ambany
X= master pin | ?= access pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)

ADD A TEMPORARY PIN (this time-based pin will not work after “DD” days).

Ghost Controls-Axwk-Wireless-Keypad-FIG- (10)

Araho eto ambany
X= master pin | ?= temp pin | (SUCCESS= hearing 3 beeps, pause, 2 beeps)

ADDA  USE-BASED TEMPORARY PIN (This use-based pin will not work after “UU” uses)

Ghost Controls-Axwk-Wireless-Keypad-FIG- (11)

Araho eto ambany
X= master pin | ?= use temp pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)

DELETE AN ACCESS PIN (You can no longer use this pin to operate the gate)

Ghost Controls-Axwk-Wireless-Keypad-FIG- (12)

Araho eto ambany
X= master pin | ?= access pin deleting | (SUCCESS = hearing 3 beeps, pause, 2 beeps)

REPLACE MASTER PIN (do not give out your master pin to allow access).

Ghost Controls-Axwk-Wireless-Keypad-FIG- (13)

Araho eto ambany
X= master pin | N = new master pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)

PROGRAMMING SPECIAL FEATURES (CAN ONLY PROGRAM USING MASTER PIN)
Ghost Controls-Axwk-Wireless-Keypad-FIG- (14)PARTYMODE® (keeps gate open to allow access to property for a set time) When you want to enable PARTYMODE®to  keep the gate in the open position and suspend the gate’s auto-close feature (if enabled), the gate opener will beep twice if there is an attempt to close the gate. This is to indicate that PARTYMODE® is enabled; therefore gate cannot be closed. Follow the steps below:

Ghost Controls-Axwk-Wireless-Keypad-FIG- (15)

X= master pin | (SUCCESS = hearing 2 beeps)
Ghost Controls-Axwk-Wireless-Keypad-FIG- (16)PARTYMODE SECURETM AND 1KEYTM (use any number key and send the key to operate the gate to allow access). When you want to enable PARTYMODE SECURETM or 1KEYTM, any number ke, and the SEND key will operate the gate without the need to enter an ACCESS pin. The green LED button will stay on when any key is pressed to indicate the keypad is in 1KEYTM mode.

Araho ny dingana etsy ambany.

Ghost Controls-Axwk-Wireless-Keypad-FIG- (17)
X = master pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)

Ghost Controls-Axwk-Wireless-Keypad-FIG- (19)VACATIONMODE® (keeps gate closed, NO access to property) When you want to enable VACATIONMODE® to keep the gate in the closed position (gate has to be closed to set). GateIt will beep twice if there is an attempt to open the gate. This is to indicate that VACATIONMODE® is enabled, and the gate can not be opened. Follow the  steps below:

Ghost Controls-Axwk-Wireless-Keypad-FIG- (20)

X= master pin | (SUCCESS = hearing 2 beeps)

Ghost Controls-Axwk-Wireless-Keypad-FIG- (18)

TOROHEVITRA FAHAMARINANA

TOROHEVITRA FAHAMARINANA
sata        Ghost Controls-Axwk-Wireless-Keypad-FIG- (14)      BUZZER    Ghost Controls-Axwk-Wireless-Keypad-FIG- (16)                                                                                                                            DescriptionGhost Controls-Axwk-Wireless-Keypad-FIG- (19)

Jiro LED

ara-dalàna MODE
NIALA NIALA NIALA NIALA NIALA Unit in sleep mode
1 miposaka fohy 1 bip fohy N / A N / A N / A When any key is pressed provides visual and audio feedback
2 miposaka fohy 2 bip fohy N / A N / A N/AThe unit t enters sleep mode after 2 short blinks and beeps
ON mandritra ny 2 segondra ON mandritra ny 2 segondra N / A N / A N / A Too many PIN entry attempts. The unit goes to shut-down mode for 1 min.
N / A N / A ON NIALA NIALA Ghost Controls-Axwk-Wireless-Keypad-FIG- (14)is pressed, the MASTER PIN entry is expected next
 

N / A

 

N / A

 

NIALA

 

ON

 

NIALA

Ghost Controls-Axwk-Wireless-Keypad-FIG- (16)is pressed, MASTERPIN entry is expected next, or the keypad is already operating in PARTYSECURETM or 1KEYTM mode.
N / A N / A NIALA NIALA ON Ghost Controls-Axwk-Wireless-Keypad-FIG- (19)is pressed, the MASTER PIN entry is expected next
MODE FAMPANDROSOANA
 

 

3 miposaka fohy

 

3 bip fohy

 

3 blinks and stay ON

 

3 blinks and stay ON

 

3 blinks and stay ON

Successful initial entry into PROGRAM mode (Program key is pressed while unit is in sleep mode). The unit will automatically return to normal operation after 60 seconds of inactivity.
1 miposaka fohy 1 bip fohy ON ON ON When any key is pressed, to provide visual and audio feedback
3 short blinks PAUSE

2 miposaka fohy

3 short blinks PAUSE

2 miposaka fohy

ON during beeping, then OFF ON during beeping, then OFF ON during beeping, then OFF Successfully completed programming sequence
 

ON mandritra ny 2 segondra

 

ON mandritra ny 2 segondra

 

ON dia OFF

 

ON dia OFF

 

ON dia OFF

Invalid entry during programming mode. Programming is not successful. Unit exits to

fandidiana ara-dalàna

FACTORY DEFAULT MEMORY
 

3 long blinks PAUSE

2 miposaka fohy

 

3 long blinks PAUSE

2 miposaka fohy

 

 

3 mipy

 

 

3 mipy

 

 

3 mipy

The unit’s PIN memory and settings are in Factory Default Mode. No other function is operational until the unit is initialized. Please refer to tthe FISORONANA VOALOHANY section to initialize the unit.
 

2 long blinks PAUSE

2 miposaka fohy

 

2 long blinks PAUSE

2 miposaka fohy

 

2 mipy

 

2 mipy

 

2 The unit’s

s RF transmitting code is still at factory default (blank). Refer to the LEARN TRANSMITTER section to program a transmitter’s code to the keypad.