ST Engineering Mirra CX1-2AS Plus LoRaWAN Meter Interface Unit
Instrucións de uso do produto
- The product is designed to operate within specified mechanical and environmental conditions to ensure optimal performance.
- Choose a suitable location for the Mirra CX1-2AS Plus unit near the metering equipment.
- Ensure proper power supply and connectivity options are available in the installation area.
- Mount the unit securely using the provided mounting hardware.
- Once installed, follow these steps to configure the unit:
- Access the configuration interface using the provided credentials.
- Set up communication parameters as per your network requirements.
- Adjust the alarm settings based on your preferences.
- Monitor the data readings and alerts displayed on the unit interface.
- Respond to any alarms or notifications promptly to ensure system integrity.
Características clave
- Water meter interface unit
- LoRaWAN communication (AS923MHz)
- Remote scheduled data reporting
- Función de aforro de enerxía
- Battery life (up to 15 years)
- Integrated pulse sensor
- Battery replacement at site
- Support Firmware-Over-The-Air upgrade
- Infrared for short range configurations
- Alarms (Backflow, Overflow, low battery voltage, anti-tampering, high temperature, Last Gasp, storage exception alarm)
- Secured data protection: AES256
Conforme ao produto
- Safety: EN 61010-1:2010+A1:2019
- EMC:EN IEC 61326-1:2021
- RF:EN 300220-1 EN 300220-2FCC Part15
- ENVR:EN 60068-2-30:2005, EN 60068-2-2:2007,EN 60068-2-1:2007, IEC 60068-2-38:2021
- RoHS: EN 62321
- Ingress: IEC 60529:1989+A1:1999+A2:2013
- Entrusted: IEC 62262:2002+A1:2021
- Reliability: IEC 62059-31-1
- Drop: IEC 60068-2-31:2008
Mecánica / Ambiente de traballo
- Dimensions: 121(L)x100(D)x51(H) mm
- Peso: 0.26 kg
- Temperatura de funcionamento: -20°C a +55°C
- Operating humidity: <95% non-condensing
- Protección de entrada: IP68
- Valoración de impacto: IK08
MIU Certifications
- FCC (EEUU)
- CE (Europa)
- ATEX (Ꜫꭓ) –In accordance with Directive 2014/34/EU
- Quality: STEURS ISO 9001 & ISO 14001
Especificacións técnicas
Technical Specifications (V2.0)
COMMUNICATIONS / NETWORK | |||
Protocolo de transmisión | LoRaWAN V1.0.2 Class A | Taxa de datos | 0.018 -37.5 kbps |
Topoloxía | Estrela | Ancho de banda | 125/250/500 KHz configurable |
Banda de frecuencia | 902.3-927.7 MHz | Center Frequency | Pódese personalizar |
Potencia TX | 20 dBm(max) | Ganancia de antena | <1.0 dBi |
SENSIBILIDADE RX | -139 dBm@SF12/125kHz | Seguridade dos datos | AES256 data encryption (dynamic) |
Tipo de antena | Internal (Omi-directional) | ||
DATA READING | |||
Data accuracy | Depends on the water meter | Almacenamento de datos | Up to 30 days of data storage |
Data reporting interval | Default 1 time/day, configurable up to 3 times/day | Intervalo de rexistro de datos | Up to 30 minutes data interval |
Device/Environment status data | MIU firmware version, MIU time (real), Device temperature (°C), | Others data | Number of transmissions, Daily battery voltage level, Data timestamp, Data size |
MIU identification data | MIU code (unique), devEUI, AppKey, Water meter code | Datos medidos | Cumulative flow, Cumulative positive flow, Cumulative reverse flow, Collection time, |
ALARMAS | |||
Refluxo de auga | Soportado | High temperature report | Soportado |
Batería baixa voltage | 3.3 V | MIU removal (tamper) | When MIU is removed from the water meter |
Last Gasp | Fallo da batería | Storage exception alarm | MIU internal memory failure |
Alarma de desbordamento | Soportado | ||
CONFIGURACIÓNS | |||
No. of days of lost data | Data storage up to 7 days for retrieval | Data transmission/logging interval | Max. up to 3 times/day / up to 15 minutes |
Sincronización horaria | Soportado | Local configuration capability | Infravermello |
CARACTERÍSTICAS | |||
Reloxo en tempo real (RTC) | Soportado | Firmware OTA upgrade | Soportado |
Integrated pulse sensor | Accuracy up to 99.9% Precision up to 0.1L per pulse | Last Gasp | Soportado |
Interfaces externas | Inductive pulse, Infrared | Sensor de temperatura | Soportado |
AMBITO DE FUNCIONAMENTO | |||
Temperatura de funcionamento | -20 °C a +55 °C | Temperatura de almacenamento | -20 °C a +55 °C |
Humidade de funcionamento | <95% RH sen condensación | Humidade de almacenamento | <99% RH sen condensación |
Protección de entrada | IP68 | Entrusted protection | Impact IK08 |
ALIMENTACIÓN | |||
Tipo de batería | Litio | Corrente de arranque da transmisión |
< 80mA |
Duración da batería | 15 years (transmission interval, by default 1 time/day), 10 years (transmission interval is 3 times/day) | MIU power consumption during transmission |
Datos Sampling per times: <0.30uAh Data Report per times: 15uAh |
Consumo de enerxía | < 200mW | Capacidade nominal da batería | 19 Ah |
Modo de espera | <100uW | Fuga de almacenamento da batería | <1% ao ano @ +25 °C |
SISTEMA | |||
Dispoñibilidade | Baixo demanda | Single cast | Soportado |
Device trigger/activation | Magnetic sense | ||
CUMPRIMENTO | |||
Seguridade | EN 61010-1:2010+A1:2019 | radio RF | EN 300220-1, EN 300220-2
FCC Parte 15 |
EMC | EN IEC 61326-1:2021 | Ambiental | EN 60068-2-30:2005, EN 60068-2-2:2007
EN 60068-2-1:2007, IEC 60068-2-38:2021 |
RoHS | EN 62321 | Protección de entrada | IEC 60529:1989+A1:1999+A2:2013 |
Entrusted | IEC 62262:2002+A1:2021 | Fiabilidade | IEC 62059-31-1 |
CERTIFICATIONS / QUALITY | |||
Europa | CE VERMELLO | Explosivo | ATEX |
STEURS ISO 9001 | Deseño e desenvolvemento | STEURS ISO 14001 | Manufacture, Supply, Installation, Maintenance |
MECÁNICA | |||
Dimensións | 121 (L) x 100 (P) x 51 (Al) mm | Material de carcasa | ABS UV treated |
Peso | 0.26 kg | Cor da carcasa | Pantone Color: Cold grey 1C |
Dimensión
Declaración da FCC
Este equipo cumpre cos límites de exposición á radiación da FCC establecidos para un ambiente non controlado. Este equipo debe instalarse e operarse cunha distancia mínima de 20 cm entre o radiador e o seu corpo.
Aviso da FCC
Este dispositivo cumpre coa Parte 15 das normas da FCC. O funcionamento está suxeito ás dúas condicións seguintes:
- Este dispositivo pode non causar interferencias prexudiciais e
- este dispositivo debe aceptar calquera interferencia recibida, incluídas as que poidan causar un funcionamento non desexado.
Nota: Este equipo foi probado e comprobouse que cumpre cos límites para un dispositivo dixital de Clase B, segundo a parte 15 das normas da FCC.
Estes límites están deseñados para proporcionar unha protección razoable contra interferencias daniñas nunha instalación residencial. Este equipo xera, utiliza e pode irradiar enerxía de radiofrecuencia e, se non se instala e se usa de acordo coas instrucións, pode causar interferencias prexudiciais nas comunicacións por radio. Non obstante, non hai garantía de que non se produzan interferencias nunha determinada instalación. Se este equipo causa interferencias daniñas na recepción de radio ou televisión, o que se pode determinar acendendo e apagando o equipo, recoméndase ao usuario que intente corrixir a interferencia mediante unha ou máis das seguintes medidas:
- Reorienta ou reubica a antena receptora.
- Aumentar a separación entre o equipo e o receptor.
- Conecte o equipo a unha toma dun circuíto diferente ao que está conectado o receptor.
- Consulte ao distribuidor ou a un técnico experimentado de radio/TV para obter axuda.
NOTA 2: Calquera cambio ou modificación desta unidade non aprobada expresamente pola parte responsable do cumprimento pode anular a autoridade do usuario para utilizar o equipo.
CONTACTO
- ST Engineering Urban Solutions Ltd.
- www.stengg.com
- URS-Marketing@stengg.com
- © 2021 ST Engineering Electronics Ltd. All rights reserved.
FAQ
- Q: What should I do if I encounter a storage exception alarm?
- A: If you receive a storage exception alarm, check the storage capacity of the unit and ensure it is not exceeded. Clear out unnecessary data or increase storage capacity as needed.
- Q: How do I know if tampering is detected by the unit?
- A: The unit will trigger a tampering alert indicating any unauthorized access or interference with the device. Review o tamper event log in the unit’s interface for details.
- Q: Can I adjust the temperature threshold for high temperature alerts?
- A: Yes, you can typically adjust the temperature threshold in the unit’s settings to customize when high temperature alerts are triggered based on your specific requirements.