Generic 20 Minute Override Control User Guide

20 Minute Override Control

Specifications:

  • Model: 20-40-60 Control
  • Power: 12V
  • Terminal Positions: Remote 6 & 7, Remote 10, Remote 4 &
    6, On-board
  • Cable Type: 22/4

Installation:

  1. Unplug the ventilation unit before starting.
  2. Choose a convenient location for the control on the wall.
  3. Route a cable (type 22/4) from the unit to the control
    location.
  4. Mark and drill mounting screw holes for the control.
  5. Strip the cable end to access the 4 wires and strip each wire
    end.
  6. Connect the wires to the control terminals using screws,
    regardless of wire color.
  7. Mount the control securely on the wall.

Usage Instructions:

  1. Based on the fresh air system installed, connect the control to
    the unit’s terminal connector following one of the four illustrated
    models.
  2. Ensure to match wire colors with the correct terminals as noted
    during installation.
  3. The indicator on the control will light up according to the
    selected duration, and the system will exchange air at maximum
    speed.

FAQ:

Q: Can this control be used with a previous generation
auxiliary control?

A: In a retrofit application, this control cannot share a 3-wire
connection with previous generation auxiliary controls. A dedicated
cable is required for proper functionality.

Q: What should I do if the indicator light does not turn
on?

A: Check the wiring connections and ensure they are secure. If
the issue persists, consult a qualified technician for further
assistance.

“`

INSTALLATION AND USER GUIDE FOR 20-40-60 CONTROL

READ AND SAVE THESE INSTRUCTIONS

The illustrations in this document are generic; your control appearance may be slightly different from the ones shown.

! WARNING
Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. Always wear safety glasses and gloves while performing these instructions.

INSTALLATION Unplug the ventilation unit.

Remote 6 & 7 positions terminals
12V LED OVR Gnd

Cut a 27/8″ x 1¾” hole in a wall, at a
convenient location for the control. Route a cable (type 22/4) for the control from the unit to this hole. See figure at right.

VC0234

Remote 10 positions terminal

Temporarily place the control over the
hole and mark both mounting screw hole positions.

Ø 3/16″, typ.

Remove the control, drill both screw
holes (3/16″ Ø) in wall and insert the wall anchors (included).

VC0210A

Strip the end of the cable to access the 4 wires (about 3″). Strip
the end of each wire (about 1/4″). Use screws to fix the wires to the control terminals, regardless of the wire color. Note which wire color has been chosen for each terminal. Pull slightly on each wire to make sure they are firmly connected.

VE0487

Remote 4 & 6 positions terminals

VE0488

On-board terminal

12V LED OVR Gnd

VC0233
Mount the control to the wall.

VE0489A
NOTE: The auxiliary wall control can be used with a 3-wire connection by removing the LED signals. In 3-wire, the control will activate LEDs according to the mode selected directly on it (20-40-60), but the LEDs will not interact after others auxiliary controls in the same installation are activated. In retrofit application, this control cannot share a 3-wire connection with previous generation auxiliary controls. A dedicated cable is required.
Plug the ventilation unit and test the wall control.

HOW TO USE THE CONTROL

VC0211
Depending on the type of fresh air system installed,
perform the electrical connection to the terminal connector of the unit as per one of the four models illustrated hereafter. For more details, refer to the installation manual of the ventilation unit.
NOTE: To avoid miswiring, refer to the notes taken at step
to match the wire color with the right terminal.

The main button works following this sequence: · Click 1 = 20 min · Click 2 = 40 min · Click 3 = 60 min · Click 4 = OFF · and so on
The indicator lights up as per the selected duration and the system exchanges air at MAX speed.

VC0212

23849 rev. E

GUIDE D’INSTALLATION ET D’UTILISATION DE LA COMMANDE 20-40-60

VEUILLEZ LIRE ET CONSERVER CES DIRECTIVES

Les illustrations de ce document sont générales; l’apparence de votre commande peut légèrement différer de celles-ci.

! AVERTISSEMENT
Le branchement électrique doit être effectué par du personnel qualifié conformément aux codes et aux standards en vigueur. Avant d’effectuer le branchement, débrancher l’appareil ou couper l’alimentation électrique au panneau de distribution et le verrouiller pour éviter une mise en marche accidentelle. Toujours porter des lunettes et des gants de sécurité lors de l’exécution de ces instructions.

INSTALLATION

Borniers distants à 6 et 7 positions

12V

Débrancher l’appareil de ventilation.

LED

OVR

NOTE: Si la commande est installée dans un boîtier électrique,

Gnd

passer à l’étape .

Découper un trou de 27/8 po x 1¾ po
dans un mur, à un endroit pratique pour l’emplacement de la commande. À partir de l’appareil, acheminer un câble (type 22/4) pour la commande jusqu’à ce trou. Voir ci-contre.

VC0234

Bornier distant à 10 positions

Placer la commande temporairement
au-dessus du trou et marquer la position des deux trous pour les vis de montage.

Ø 3/16 po, typ.

Retirer la commande, percer les deux
trous (3/16 po Ø) des vis dans le mur et y insérer les douilles à expansion (incluses).

VC0210F

VE0487

Borniers distants à 4 et 6 positions

Dégainer l’extrémité du câble pour accéder aux 4 fils (environ
3 po). Dénuder le bout de chaque fil (environ 1/4 po). Utiliser les vis pour connecter les fils aux bornes, sans tenir compte de la couleur des fils. Pour chaque borne, prendre en note la couleur de fil choisie. Tirer légèrement sur chaque fil pour s’assurer qu’ils sont bien connectés.

VE0488
Bornier intégré
CARTE ÉLECTRONIQUE

VC0233

VE0489F

12V

NOTE : La commande murale auxiliaire peut être utilisée avec une

LED

connexion à 3 fils en enlevant les signaux « LED ». Dans

OVR

une connexion à 3 fils, la commande activera ses DEL

Gnd

selon le mode choisi (20-40-60), mais ces mêmes DEL ne

seront pas activées si d’autres commandes auxiliaires dans

la même installation sont activées. Lors d’installation avec

une ancienne génération d’appareil, cette commande ne peut

utiliser une connexion à 3 fils partagée avec d’anciennes

commandes; elle doit avoir son propre câble dédié.

Brancher l’appareil de ventilation et tester la commande murale.

COMMENT UTILISER LA COMMANDE

Assembler la commande au mur.
VC0211
En fonction du type d’échangeur d’air installé, raccorder au
bornier de l’appareil selon l’un des quatre modèles illustrés ci-après. Pour plus de détails, consulter le guide d’installation de l’appareil de ventilation. NOTE: Afin d’éviter une connexion erronée, se reporter aux
notes prises à l’étape sur les couleurs de fils. VC0212

Le bouton principal fonctionne selon cette séquence: · Clic 1 = 20 min · Clic 2 = 40 min · Clic 3 = 60 min · Clic 4 = ARRÊT · Ainsi de suite
L’indicateur s’allumera selon la durée sélectionnée et le système échangera l’air à vitesse MAX.
23849 rév. E

Documents / Resources

Generic 20 Minute Override Control [pdf] User Guide
20 Minute Override Control, 20, Minute Override Control, Override Control, Control

References

Leave a comment

Your email address will not be published. Required fields are marked *