FRIGIDAIRE FG7T logo

TECHNICAL
SPECIFICATIONS

FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces

FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces - icon

FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces

Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces Induced Draft – 96% AFUE Input 60,000 – 115,000 Btuh

The high efficiency upflow gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The extended flush jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the  United States.

FEATURES and BENEFITS

  • iSEERTM : Energy efficient brushless DC (ECM) variablespeed motor can give up to 1 SEER point efficiency gain in cooling with 16 speeds in heating and cooling.
  • SmartLite® Technology: Auto-adjusts igniter on time to extend igniter life.
  • Hot Surface Igniter: Innovative application of a silicon nitride type igniter.
  • 30 Second Blower Delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
  • 30 Second Post Purge: Increases life of heat exchanger.
  • 90 Second Fixed Cooling Cycle Blower-Off Delay (TDR): Increases cooling performance when matched with a Nortek Global HVAC coil.
  • Color Coded Wire Harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • Diagnostic Lights: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
  • Integrated Control Boards: With connections for electronic air cleaner, humidifier, and dehumidification.
  • 2 Stage Inducer: Optimizes efficiency on first stage heat and reduces sound levels.
  • Heat Exchanger: Heavy gauge aluminized steel primary heat exchanger and stainless steel secondary heat exchanger assures a long life.
  • 100% Fired and Tested: All units and each component are tested on the manufacturing line.
  • Best Packaging in the Industry: Unique corner post design assures product will arrive to the homeowner dent free.
  • Flexible Category IV Venting System: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • LP Convertible: Simple burner orifice and regulator spring change for ease of convertibility (as an accessory).
  • Two Piece Door Design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
  • Blower Compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation.
  • Sealed Vestibule: Reduces burner and inducer sound levels.
  • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

LOCATION OF FURNACE COMPONENTS

FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces - FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces

FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces - DOWNFLOW FURNACE

DIMENSIONS

*TE Model #’s Dimension “A” Dimension “B” Dimension “C”
060D-VB1 17 1/2 15 7/8 16 1/8
080D-VC1 21 19 3/8 19 5/8
100D-VC1
115D-VD1 24 1/2 22 7/8 23 1/8

FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces - DIMENSIONS

*TN Model #’s Dimension “A”  Dimension “B” Dimension “C”
060D-VB1 17 1/2 15 7/8 16 1/8
080D-VC1 21 19 3/8 19 5/8
100D-VC1
115D-VD1 24 1/2 22 7/8 23 1/8

FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces - DIMENSIONS 2

BLOWER PERFORMANCE – FG7TE/TN

NOMINAL HEATING AIRFLOWS (CFM) AND TEMPERATURE RISE (°F)
“B” CABINET
RISE 30° F TO 60° F
SWITCH SETTINGS FOR HEAT (0 = OFF, 1 = ON) *TE/*TN – 060D – VB1 INPUT (BTU) 60,000
1 2 3 4 CFM TEMP RISE (° F)
1 0 0 0 1,000 53
1 0 0 1 1,100 48
1 0 1 0 1,200 44
1 0 1 1 1,300 41
1 1 0 0 1,400 38
1 1 0 1 1,500 35
1 1 1 0 1,600
1 1 1 1 1,700
“C” CABINET
RISE 35° F TO 65° F
SWITCH SETTINGS FOR HEAT (0 = OFF, 1 = ON) *TE/*TN – 080D – VC1 INPUT (BTU) 80,000 *TE/*TN – 100D – VC1 INPUT (BTU) 100,000
1 2 3 4 CFM TEMP RISE (° F) CFM TEMP RISE (° F)
# 0 0 0 1,000 1,000
# 0 0 1 1,115 63 1,115
# 0 1 0 1,230 57 1,230
# 0 1 1 1,345 52 1,345 65
# 1 0 0 1,460 48 1,460 60
# 1 0 1 1,575 45 1,575 56
# 1 1 0 1,690 42 1,690 52
# 1 1 1 1,805 39 1,805 49
“D” CABINET
RISE 40° F TO 70° F
SWITCH SETTINGS FOR HEAT (0 = OFF, 1 = ON) *TE/*TN – 115D – VD1 INPUT (BTU) 115,000
1 2 3 4 CFM TEMP RISE (° F)
# 0 0 0 1,500 68
# 0 0 1 1,615 63
# 0 1 0 1,730 59
# 0 1 1 1,845 55
# 1 0 0 1,960 52
# 1 0 1 2,075 49
# 1 1 0 2,190 46
# 1 1 1 2,305 44
  1. Two openings are recommended for airflows above 1,600 CFM if the filter(s) is (are) adjacent to the furnace.
  2. Temperature rises in the table are approximate. Actual temperature rises may vary.
  3. Temperature rises shaded in grey are for reference only. These conditions are not recommended.
  4. Rated static is .5″ ESP in W.C.

COOLING AIRFLOW

Sunrinx MG61-8-TP Fun 16 ft Round Backyard - COOLING AIRFLOW

VENTING

All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths.

FURNACE MODELS (BTU) FURNACE INSTALLATION SINGLE PIPE LENGTH (FT.)
with 1 long radius elbow**
DIRECT VENT, DUAL PIPE LENGTH (ft.) WITH
1 long radius elbow on each pipe**
OUTLET OUTLET INLET/OUTLET INLET/OUTLET
2” Diameter 3” Diameter 2” Diameter 3” Diameter
60,000 Upflow 90 90 60 90
Downflow 30 90 30 90
80,000 Upflow 40 90 40 90
Downflow 30 90 30 90
100,000 Upflow 30 90 30 90
Downflow 30 90 25 90
115,000 Upflow N/A 90 N/A 90
Downflow N/A 90 N/A 90

*NOTES:

  1. Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Subtract 5ft for each 2” tee and 8ft for  each 3” tee.
  2. Two 45 degree elbows are equivalent to one 90 degree elbow.
  3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.

MODEL IDENTIFICATION CODE

FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces - MODEL IDENTIFICATION CODE

SPECIFICATIONS

FG7TE/TN MODELS NUMBERS: -060D-VB1 -080D-VC1 -100D-VC1 -115D-VD1
Input – Btuh (a) 60,000 / 39,000 80,000 / 52,000 100,000 / 65,000 115,000 / 74,750
Heating Capacity – Btuh 57,600 / 37,440 76,800 / 49,920 96,000 / 62,400 110,400 / 71,760
AFUE 96 96 96 96
Motor FLA 6.2 8.7 8.7 11.70
Rated Ext. SP – In. W.C. 0.5 0.5 0.5 0.5
Temperature Rise Range – ºF 30-60 35-65 35-65 40-70
Shipping Weights 125lbs 135lbs 145lbs 160lbs

Note:
All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.

ACCESSORIES

FG7TE/TN KITS
Description SKU
2″ Concentric Vent Kit 904177
3″ Concentric Vent Kit 904176
2″ Concentric Vent Kit (Canadian Approved) 904952
3″ Concentric Vent Kit (Canadian Approved) 904953
“A” Cabinet Downflow Sub Base Kit 902974
“B”, “C”, “D” Cabinet Downflow Sub Base Kit 904911
2″ Side Wall Vent Kit 904617
3″ Side Wall Vent Kit 904347
U.S. LP Conversion Kit (0 to 10,000 ft.) 905028
Canada LP Conversion Kit (0 to 4,500 ft.) 905029
Bottom Return Filter 20 per Box, “B” Cabinet 904916
Bottom Return Filter 20 per Box, “D” Cabinet 904918
Side Return Filter Kit 541036
Neutralizer Kit 902377

FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces - icon 2

GENERAL TERMS OF LIMITED WARRANTY

Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (02/2018)

FRIGIDAIRE FG7T logo

730E-0218 (Replaces 730E-0617)
www.frigidairehvac.com
FRIGIDAIRE is a registered trademark of Electrolux Home Products Inc. and used under a
license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved.

Documents / Resources

FRIGIDAIRE FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces [pdf] User Manual
FG7T Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces, FG7T, Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces, Variable Speed Condensing Upflow and Downflow Gas Furnaces, Speed Condensing Upflow and Downflow Gas Furnaces, Condensing Upflow and Downflow Gas Furnaces, Upflow and Downflow Gas Furnaces, Downflow Gas Furnaces, Gas Furnaces