Formlabs logo

SLS POWDERS


Nylon 12 GF Powder


For stiff, stable, functional parts.

A high-performance SLS material for in-house production of parts that require high rigidity, dimensional accuracy, and thermal stability.

Specifically developed for use on the Fuse Series Printers.


Fixtures Undergoing Long-Term Sustained Loading

Stiff Structural Components

End-Use Industrial Parts

Functional Prototypes for composite products

Thermally Stressed Housings

 

Nylon 12 GF Formlabs Authorised Partner 0

(V1) FLP12B01


Prepared 02/01/2022
Rev. 01 02/01/2022 1
To the best of our knowledge the information contained herein is accurate. However, Formlabs, Inc. makes no warranty, expressed or implied, regarding the accuracy of these results to be obtained from the use thereof.

Material Properties METRIC 1,2 IMPERIAL 1,2 METHOD
Mechanical Properties METRIC 1,2 IMPERIAL 1,2 METHOD
Ultimate Tensile Strength 38 MPa 5510 psi ASTM D638-14 Type 1 
Tensile Modulus 2800 MPa 406 ksi ASTM D638-14 Type 1
Elongation at Break (X/Y) 4% ASTM D638-14 Type 1
Elongation at Break (Z) 3% ASTM D638-14 Type 1
Flexural Properties METRIC1,2 IMPERIAL1,2 METHOD
Flexural Strength 56 MPa 8122 psi ASTM D790-15
Flexural Modulus 2400 MPa 348 ksi ASTM D790-15
Impact Properties METRIC1,2 IMPERIAL1,2 METHOD
Notched Izod 36 J/m 0.67 ft-lb/in ASTM D256-10
Thermal Properties METRIC1,2 IMPERIAL1,2 METHOD
Heat Deflection Temp. @ 1.8 MPa 113 °C 235 °F ASTM D648-16
Heat Deflection Temp. @ 0.45 MPa 170 °C 338 °F ASTM D648-16
Vicat Softening Temperature 175 °C 347 °F ASTM D1525
Other Properties METRIC1,2 IMPERIAL1,2 METHOD
Moisture Content (powder 0.23% ISO 15512 Method D
Water Absorption (printed part) 0.24% ASTM D570

Samples printed with Nylon 12 GF Powder have been evaluated in accordance with ISO 10993-1:2018, and has passed the requirements for the following biocompatibility risks:

ISO Standard Description3,4
ISO 10993-5:2009 Not cytotoxic
ISO 10993-10:2010/(R)2014 Not an irritant
ISO 10993-10:2010/(R)2014 Not a sensitizer
Flammability Properties
Testing Standard Rating
UL 94 Section 7 HB *

* Thickness of the sample tested = 3.00mm

SOLVENT COMPATIBILITY

Percent weight gain over 24 hours for a printed and post-cured 1 x 1 x 1 cm cube immersed in respective solvent:

Solvent 24 hr weight gain, %
Acetic Acid 5% 0.2
Acetone 0.2
Bleach ~5% NaOCl 0.2
Butyl Acetate 0.2
Diesel Fuel 0.6
Diethyl glycol Monomethyl Ether 0.5
Hydraulic Oil 1.0
Hydrogen peroxide (3%) 0.2
Isooctane (aka gasoline) 0.0
Isopropyl Alcohol 0.2
Mineral oil (Heavy) 1.0
Mineral oil (Light) 1.3
Salt Water (3.5% NaCl) 0.2
Skydrol 5 0.8
Sodium Hydroxide solution (0.025% PH 10) 0.2
Strong Acid (HCl conc) 0.8
Tripropylene glycol monomethyl ether  0.8
Water 0.1
Xylene 0.2

1 Material properties may vary with part geometry, print orientation and temperature.

2 Parts were printed using Fuse 1, with Nylon 12 GF powder. Parts were conditioned at 50% relative humidity and 23 °C for 7 days before testing.

3 Material properties may vary based on part design and manufacturing practices. It is the manufacturer’s responsibility to validate the suitability of the printed parts for the intended use.

4 Nylon 12 GF was tested at NAMSA World Headquarters, OH, USA.