FOAMit-LOGOFOAMit FG-20N-2-TM 20 Gallon Fog Unit With Timer

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer-PRODUCT-removebg-preview

Safety

WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!

  • FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (1)Failure to read all the instructions before operating the unit may result in personal injury or death from the improper use or the chemical solution. Anyone handling, operating or using the unit must read and understand the instructions in the manual. The buyer assumes all responsibility for safety and proper use in accordance with the instructions.
  • FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (2)Using or servicing the unit without appropriate personal protective equipment (PPE) may result in serious injury such as burns, rashes, eye, throat or lung damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin, and lungs against drifting spray.
  • FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (3)Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.
  • Pressure within the equipment may cause an unexpected release of the chemical solution and cause serious injury such as burns, rashes, eye damage, throat or lung damage and death.
  • Always depressurize and clean the unit after each use. Never leave the unit unattended while pressurized.
  • Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injury or death. DO NOT use a solution with a temperature above 100°F (37.8°C).
  • Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious injury or death. Never use the unit if it is damaged or leaking.
  • Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.
  • FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (4)Using incoming air pressure exceeding 100 psi (6.9 bar) may result in pressure buildup, explosion, serious injury or death. DO NOT exceed 100 psi (6.9 bar) incoming air pressure when operating the unit.
  • FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (5)Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death. Never use hydrocarbons or flammable products with the unit.
  • FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (6)Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush the unit with fresh water  thoroughly when switching from an alkaline to an acid or an acid to an alkaline.
  • FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (7)Touching damaged electrical cords may result in electrical shock, serious injury or death. Always inspect electrical cords and extension cords for damage before connecting the unit to power supply. DO NOT touch a damaged electrical cord, or extension cord, that is connected to power supply.

NOTICE

  • Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.
  • Use of an air lubricator before the unit may result in diminished performance and damage to the unit. Do not use an air lubricator before the unit.
  • Moisture in the air lines will damage the pump and diminish the pump life. The air must be filtered, clean, dry and free of moisture. If needed, install an air dryer before the unit.

PROTECT THE ENVIRONMENT

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (8)Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.

Service Guide

WARNING
Performing any maintenance with the unit pressurized, connected to air supply, and/or connected to electrical power may result in serious injury or death. Always ensure that the unit has been depressurized, disconnected from the air supply, and electrical power before conducting any maintenance. Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.

Maintaining Your Unit

To keep your unit operating properly, periodically perform the following maintenance procedures:

  • Inspect the pump for wear and leaks.
  • Inspect all hoses for leaks or excessive wear.
  • Ensure all hose clamps are in good condition and properly secured.
  • Check suction line and strainer for debris. Clean as needed.
  • Inspect nozzles for debris. Clean as needed.
  • Drain your air compressor tank on a regular basis to help extend pump life. An air source with a high moisture content will accelerate pump wear.

Note: If your air source has a high moisture content, install a water separator to the air fitting on the backplate. See Page 8 for more details. (Back plate assembly)

Servicing Your Unit

Most repairs on the unit can be performed with the following tools:

  • Crescent wrench (2x)
  • ⁷/16 in. (11 mm) open-ended wrench
  • Flat head screwdriver
  • Thread seal tape
  • #2 Phillips head screwdriver
  • #3 Phillips head screwdriver
  • Hose cutters
  • Knife

Troubleshooting Your Unit

If your unit is not operating properly, try using these troubleshooting tips:

Issue Solution
Pump is cycling too fast
  •  Ensure the suction line ball valve at the bottom of the tank is open.
Pump is cycling too slow
  •  Inspect the outlet side of pump for build up. Clean as needed.
Air passes through the pump without cycling
  • The pump needs to be replaced.
Chemical found in the air bowl or coming out of the pump exhaust
  • The pump diaphragm is torn, replace pump.
The unit operates at a reduced pressure
  • Check suction line and strainer for debris or damage. Clean or replace as needed. To prevent damage to the unit, the strainer must always be used.
  • Check the air compressor supplying the unit. If the pressure is less than 40 psi (2.8 bar), turn off the unit until the compressor can catch up.
  • If the air supply is 50 psi (3.4 bar) or above, check the air gauge, which should read near 50 psi (3.4 bar). If the air gauge reads more or less than 50 psi (3.4 bar), adjust pressure by turning the knob on the top of the air regulator.

Tank Assembly

TNKA-20N-IN-BK:
20 gallon natural tank assembly with side inserts – black* lid – includes drain plug, wheels, suction valve, and backplate thumb nuts

LDA-7BK:
Lid assembly – includes 7 in. black* lid, lid flange, hinge pin, and mounting screws

Item number Description
1 LD-PIN Hinge pin for 7 in. lid and flange
2 LD-7BK-LID Lid – 7 in. – polypropylene – black*
3 S812-FH Screw – #8 x 1/2 in. – stainless steel – flat head Phillips
4 LD-7BK-FLNG Lid flange – 7 in. – polypropylene – black*

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (10) FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (10)

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (15) FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (15)* Additional colors available, see datasheet for options.

Item number Description
5 TNK-20N Tank – 20 gallon natural – portable
6 DPA Drain plug assembly for portable units – includes gasket

TNKA-20N-IN-BK:
20 gallon natural tank assembly with side inserts – black* lid – includes drain plug, wheels, suction valve, and backplate thumb nuts

BPTNA:
Back plate thumb nut assembly – includes bolt, thumb nut, and tether

Item number Description
1 BST1420118-VS Bolt – set – 1/4-20 x 1 1/8 in. – stainless steel – Vibra-Seal
2 TN1420 Thumb nut – 1/4-20 x 1 1/4 in. – PP – brass insert – assembled with tether

VLVA-BVPVC34:
Suction valve assembly – includes 3/4 in. PVC valve, bushing, 3/4 in. hose barb elbow, and screw band clamp

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (15) FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (15)

Item number Description
3 SSC38 Screw band clamp – stainless steel – for 3/8 in. hose
4 BVPVC34MF Ball valve – PVC – 3/4 NPT to 3/4 FNPT – Buna seal
5 HHPB3414 Hex head poly bushing – 3/4 in. MPT x 1/4 in. FPT
6 HBSSEL1438 Hose barb – stainless steel – elbow – 1/4 in. MPT x 3/8 in. barb

WHLA-AXL15:
10 in. wheel assembly – includes 15 in. stainless steel axle, axle plate, bolts, washers, and cotter pins

Item number Description
7 COT Cotter pin – stainless steel – 1/8 in. dia x 1 in. long
8 PLSS-AXL Axle plate – stainless steel – 2.5 in. x 1 in. – 2 holes
9 AXL15 Axle – stainless – 0.625 dia. x 15.45 in.
10 B142012-VS Bolt – 1/4-20 x 1/2 in. – stainless steel – truss head Phillips – Vibra-Seal
11 W10 Wheel – 10 in. – non-marking
 12  FW58 Flat washer for 5/8 in. od pipe or axle – stainless steel – 0.64 in. id x 1.2 in. od x 0.05 in. thk

Back Plate Assembly

PA-PNZ-TM:
Plate assembly for portable fog units with timer – Santoprene pump

Additional plate assembly pump options:

  • PA-PNZK-TM: Kalrez pump
  • PA-PNZV-TM: Viton pump
Item number Description
 1  A P56 Pump with Santoprene seals – includes hose barbs, air fitting, and exhaust barb
 B P56K Pump with Kalrez seals – includes hose barbs, air fitting, and exhaust barb
 C P56V Pump with Viton seals – includes hose barbs, air fitting, and exhaust barb
2 R14 Regulator – air – 4x 1/4 in. FPT ports – no gauge
 3  QF5638 Quick fit pump fitting for 3/8 in. tube – EPDM o-ring – for G57/P56 – sold individually
4 AG100 Air gauge – ⅛ in. NPT – 0-100 PSI markings – dry model
5 QFEL1438 Fixed elbow 1/4 in. MPT x 3/8 in. tube – polypropylene
6 H14BL-F ¼ in. id blue hose – hybrid TPE – available per ft.
7 QFBH38 Bulkhead 3/8 in. tube polypropylene
 8  STR38-IL-80 In line strainer – 2x 3/8 hose barb – EPDM gasket – #80 mesh SS screen – gray bowl
9 H38BL-F ⅜ in. id blue hose – hybrid TPE – available per ft.
10 QFSEL38 Plug-in elbow 3/8 in. tube x 3/8 in. polypropylene
11 TB38N-PE 3/8 in. od natural tube – polyethylene – available per ft.

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (12)

PA-PNZ-TM:
Plate assembly for portable fog units with timer – Santoprene pump

Additional plate assembly pump options:
PA-PNZK-TM: Kalrez pump
PA-PNZV-TM: Viton pump

Item number Description
1 SEL14M Stainless elbow 1/4 in. MPT x 1/4 in. MPT
2 SSSFN12 Serrated flange nut – stainless – ½ in.
3 SSA14BKH Bulkhead adapter – stainless steel – 1/4 in. NPT x 1/4 in. NPSM
4 BVB14 Ball valve – brass – nickel plated – air inlet valve – 1/4 in. FPT x 1/4 in. FPT
5 QF1438 Quick fit – 1/4 MPT x 3/8 od tube- polypropylene
6 TB38N-PE 3/8 in. od natural tube – polyethylene – available per ft.
7 QFBH38 Bulkhead 3/8 in. tube polypropylene
8 ACB-PLPF- 120VAC Air control box – PLPF – 120VAC – delay timer – push button – toggles – circuit breaker
9 AP14 Air fitting – 1/4 in. MPT quick disconnect hose coupling plug – nickel-plated brass

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (12) FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (12)

Optional Components
WSA-20CFM:
Water separator assembly – 20 CFM – ¼ in. FPT ports – includes air plug and union fittings

Item number Description
10 SN1414 Stainless hex nipple ¼ MPT x ¼ MPT
11 SSU14 Stainless steel union – ¼ in. FPT
12 WS-20CFM Tsunami water separator/air dryer – 20 CFM – 1/4 in. FPT ports
13 AP14 Air fitting – 1/4 in. MPT quick disconnect hose coupling plug – nickel-plated brass

PA-PNZ-TM:
Plate assembly for portable fog units with timer – Santoprene pump

Additional plate assembly pump options:
PA-PNZK-TM: Kalrez pump
PA-PNZV-TM: Viton pump

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (10)

Item number Description
1 HBB14P ¼ in. hose barb – brass – for G57/P56 air fitting with o-ring
2 EC14 Ear clamp – Oetiker – stainless steel for 1/4 in. hose
3 H14BL-F ¼ in. id blue hose – hybrid TPE – available per ft.
4 HBSSEL1414 Hose barb – stainless steel – elbow – 1/4 in. MPT x 1/4 in. barb
5 R14 Regulator – air – 4x 1/4 in. FPT ports – no gauge
6 SSA14BKH Bulkhead adapter – stainless steel – 1/4 in. NPT x 1/4 in. NPSM
7 SSSFN12 Serrated flange nut – stainless – ½ in.
8 QFEL1438 Fixed elbow 1/4 in. MPT x 3/8 in. tube – polypropylene
9 HHSB1418 Hex head stainless bushing 1/4 MPT x 1/8 FPT
10 AG100 Air gauge – ⅛ in. NPT – 0-100 PSI markings – dry model

Back Plate Sub-assemblies

SCTNA-PNZ:
Suction assembly for portable fog units – includes suction valve, hose, in-line strainer, and pump hose barb – for Santoprene pump

Additional suction assembly options:
SCTNA-PNZK: Kalrez pump
SCTNA-PNZV: Viton pump

Item number Description
1 A HB5638 Hose barb for P56 pump – EPDM o-ring
B HB5638K Hose barb for P56K pump – Kalrez o-ring
C HB5638V Hose barb for P56V pump – Viton o-ring
2 STR38-IL-80 In line strainer – 2x 3/8 hose barb – EPDM gasket – #80 mesh SS screen – gray bowl
3 SSC38 Screw band clamp – stainless steel – for 3/8 in. hose
4 H38BL-F ⅜ in. id blue hose – hybrid TPE – available per ft.
5 HBSSEL1438 Hose barb – stainless steel – elbow – 1/4 in. MPT x 3/8 in. barb
6 HHPB3414 Hex head poly bushing ¾ MPT x ¼ FPT
7 BVPVC34MF Ball valve – PVC – 3/4 NPT to 3/4 FNPT Buna seal

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (15)ACB-PLPF-120VAC:
Air control box assembly – 120VAC – includes delay timer, push button, toggles, circuit breaker, and air plug

Item number Description
1 PBA-664 Poly box assembly – 6 x 6 x 4 – PVC – junction box
2 QFBH38 Bulkhead 3/8 in. tube polypropylene
3 QFSEL38 Plug-in elbow 3/8 in. tube x 3/8 in. polypropylene
4 TB38N-PE 3/8 in. od natural tube – polyethylene available per ft.
5 TSW-PLT Toggle switch – ON/OFF plate – nickel-plated steel – mounting hole for 15/32 keyed bushing
6 TSW-BDY Toggle switch – body – single pole single throw – nickel-plated brass – 1/4 in. spade terminals -1/2 in. mounting hole – 15/32-32 keyed threaded bushing
7 TSW-BT Toggle switch – mounting boot – black silicone rubber – 15/32-32 integrated nut
8 TMR-MF-120VAC Timer – multi-function relay -0.05 sec. to 10230 hr. adjustable digi-set – 120 VAC – 10 A max – uses 11 pin socket
9 QF1438 Quick fit – 1/4 MPT x 3/8 od tube- polypropylene
10 FCV14-120VAC Fluid control valve – DEMA -1/4 in. FPT – 7 GPM – polypropylene body – Viton diaphragm – 120 VAC solenoid – normally closed – 18 in. 18 AWG flying leads
11 BUT78GR Push button – flush green cap – normally open
12 FW14NPT Flat washer for 1/4 in. NPT – stainless – 0.57 in. id x 1.28 in. od x 0.08 in. thk
13 CB-5 Circuit breaker assembly – 5 amp includes clear boot
14 SSA14 Stainless adapter 1/4 MPT x 1/4 FPT
15 AP14 Air fitting – 1/4 in. MPT quick disconnect hose coupling plug – nickel-plated brass

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (15) FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (15)

Nozzle Assembly

NZA-PNZX2-WBRKT-WTB:
Nozzle assembly – includes 2x pneumatic nozzles, tank mounting bracket with mounting hardware, and tubing

NZA-PNZX2-WBRKT:
Nozzle bracket assembly – includes 2x pneumatic nozzle, and tank mounting bracket with mounting hardware

Item number Description
 1  PNZ-N130 Pneumatic mixing nozzle – polypropylene body – Kynar tip – 3.7 gal/hr
2 EL14M14F 1/4 FPT x 1/4 MPT – polypro elbow
3 BRKT-TNK-PNZX2 Bracket for tank mounting 2x PNZ nozzles – stainless steel
 4  FW14NPT Flat washer for 1/4 in. NPT – stainless – 0.57 in. id x1.28 in. od x 0.08 in. thk
5 QF1438 Quick fit – 1/4 MPT x 3/8 od tube – polypropylene
6 QFSEL38 Plug-in elbow 3/8 in. tube x 3/8 in. polypropylene
7 S1034 Screw – #10 x 3/4 in. – stainless steel – round head Phillips
Item number Description
8 QFT38 Union tee 3/8 in. tube polypropylene
9 TB38N-PE 3/8 in. od natural tube – polyethylene – available per ft.

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (15)

READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS UNIT. KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS. English (Original Instructions)

Scan this code for service manual

FOAMit-FG-20N-2-TM-2--Gallon-Fog-Unit-With-Timer- (3)

Frequently Asked Questions

  • Q: Can I use any type of chemical solution with this fog unit?
    A: No, it is important to use only chemical solutions recommended for fogging units to avoid damage and ensure proper operation.
  • Q: How often should I clean the fog unit?
    A: The unit should be cleaned and maintained after each use to prevent clogs and ensure optimal performance.
  • Q: What should I do if the timer malfunctions?
    A: If the timer malfunctions, discontinue use of the unit and contact a qualified service technician for repairs.

Documents / Resources

FOAMit FG-20N-2-TM 20 Gallon Fog Unit With Timer [pdf] User Manual
FG-20N-2-TM, FG-20N-2-TM 20 Gallon Fog Unit With Timer, FG-20N-2-TM, 20 Gallon Fog Unit With Timer, Unit With Timer, Timer
FOAMit FG-20N-2-TM 20 Gallon Fog Unit With Timer [pdf] Instruction Manual
FG-20N-2-TM 20 Gallon Fog Unit With Timer, FG-20N-2-TM, 20 Gallon Fog Unit With Timer, Gallon Fog Unit With Timer, Fog Unit With Timer, Unit With Timer, Timer

References

Leave a comment

Your email address will not be published. Required fields are marked *