1. Johdanto
The CAD Audio E100SX is a large-diaphragm supercardioid condenser microphone designed for capturing vocals and instruments with clarity and detail. It features a supercardioid polar pattern for excellent off-axis rejection, a switchable 100 Hz hi-pass filter, and a 10 dB pad for versatile control in various recording environments. The microphone is housed in a robust design with an integrated shock mount to minimize handling noise and vibrations.

Image 1.1: The CAD Audio E100SX microphone, showcasing its features for studio versatility, including the 100Hz Hi-Pass Filter, High Sensitivity, Low Frequency Response, and Versatile Applications.
2. Mitä laatikossa on
Upon unpacking your CAD Audio E100SX, please ensure all components are present and in good condition:
- CAD Audio E100SX Large-Diaphragm Supercardioid Condenser Microphone with integrated shock mount
3. Asennus
Follow these steps to set up your E100SX microphone:
- Asennus: Secure the integrated shock mount onto a standard microphone stand. Ensure the stand is stable and capable of supporting the microphone's weight.
- Yhteys: Connect a balanced XLR cable (not included) to the XLR output connector located at the base of the microphone. Connect the other end of the XLR cable to your audio interface, mixer, or preampelävämpi.
- Phantom-voima: The E100SX is a condenser microphone and requires 48V phantom power to operate. Activate the 48V phantom power on your audio interface, mixer, or preamplifier. The microphone will not function without proper phantom power.
- Paikannus: Position the microphone appropriately for your recording source. The supercardioid pattern is most sensitive directly in front of the microphone, with significant rejection from the sides and rear.

Kuva 3.1: Pohja view of the CAD Audio E100SX, illustrating the XLR output connector for audio signal transmission.

Kuva 3.2: Edessä view of the CAD Audio E100SX microphone, showing its grille and integrated shock mount for stable positioning.
4. Käyttöohjeet
The E100SX features two important switches for sound control:
- Hi-Pass Filter (100 Hz): This switch activates a low-cut filter at 100 Hz. Engage this filter to reduce unwanted low-frequency rumble, stage noise, or proximity effect when close-miking. This helps to clean up the low end of your recordings.
- Pad (10 dB): The 10 dB pad attenuates the input signal by 10 decibels. Engage this switch when recording very loud sound sources (e.g., drums, loud guitar amplifiers) to prevent overloading the microphone's capsule or your preamplifier'in panos.
Napakuvio: The E100SX utilizes a supercardioid polar pattern. This pattern offers a tight pickup area directly in front of the microphone, providing excellent isolation from sounds originating from the sides and rear. This is beneficial for minimizing bleed from other instruments in a live setting or untreated room, and for focusing on a single sound source.

Kuva 4.1: Lähikuva view of the CAD Audio E100SX, showing the Hi-Pass filter and 10 dB Pad switches for audio control.
5. Huolto
Proper maintenance ensures the longevity and optimal performance of your E100SX microphone:
- Puhdistus: Use a soft, dry cloth to wipe the microphone body. Avoid using liquid cleaners, solvents, or abrasive materials, as these can damage the finish or internal components. Do not attempt to clean the microphone grille with liquids.
- Varastointi: When not in use, store the microphone in a protective case or pouch to shield it from dust, moisture, and physical impact. Avoid exposing the microphone to extreme temperatures or high humidity.
- Käsittely: Always handle the microphone with care. Avoid dropping it or subjecting it to strong vibrations, which can affect the sensitive capsule.
6. Vianmääritys
If you encounter issues with your E100SX microphone, refer to the following common problems and solutions:
- Ei äänilähtöä:
- Ensure 48V phantom power is activated on your audio device.
- Check all XLR cable connections for proper seating and integrity. Try a different XLR cable if available.
- Varmista, että ääniliitännän tai mikserin tulosignaalin vahvistus on säädetty riittäväksi.
- Vähäinen äänenvoimakkuus tai heikko signaali:
- Confirm that the 10 dB pad switch is not engaged unless necessary for a very loud source.
- Lisää ääniliitännän tai mikserin tulosignaalin vahvistusta.
- Ensure the microphone is positioned correctly towards the sound source.
- Vääristynyt ääni:
- If the sound source is very loud, engage the 10 dB pad switch.
- Vähennä äänikortin tai mikserin tulosignaalin vahvistusta.
- Ensure the microphone is not positioned too close to an extremely loud source.
- Liiallinen matalataajuinen kohina/jyrinä:
- Engage the 100 Hz hi-pass filter switch to reduce unwanted low-end frequencies.
- Ensure the microphone stand is stable and isolated from floor vibrations.
7. Tekniset tiedot
Detailed technical specifications for the CAD Audio E100SX microphone:

Image 7.1: The CAD Audio E100SX microphone with a visual representation of its key specifications.
| Erittely | Arvo |
|---|---|
| Napainen kuvio | Supercardioidi |
| Toimintaperiaate | Lauhdutin |
| Taajuusvaste | 20 Hz – 18 kHz |
| Herkkyys | 32 dBV (25mV) @ 1 Pa |
| Impedanssi | 150 ohmia |
| Max SPL | 136 dB (with pad engaged) |
| Hi-pass suodatin | 100 Hz, 6 dB / oktaavi |
| Pad | 10 dB |
| Tehovaatimukset | 48V Phantom Power (1.6mA) |
| Itsemelu | 9.5 dBA |
| Signaali-kohinasuhde | 32 dB |
| Materiaali | Nikkelipinnoitettu |
| Tuotteen paino | 1.41 lbs (0.64 kg) |
| Tuotteen mitat (P x L x K) | 7.28 x 5.12 x 4.72 tuumaa |
| UPC | 631922109351 |
8. Takuutiedot
CAD Audio products are designed for reliability and performance. For specific warranty terms and conditions applicable to your E100SX microphone, please refer to the warranty card included with your purchase or visit the official CAD Audio websivusto. Säilytä ostokuittisi mahdollisten takuuvaatimusten varalta.
9. Tukea
For further assistance, technical support, or inquiries regarding your CAD Audio E100SX microphone, please contact CAD Audio customer service or visit their official websivusto:
- Websivusto: www.cadaudio.com
- Refer to the contact section on the websivusto puhelinnumeroita tai sähköpostitukea varten.