FERPORT XLX22024L ARMAS Externally Driven Flash
Specifications
- Dimensions: Lamp L78xH97xP36, Base L50xH25xP48
- Power Supply: 24Vac, 24Vdc, or 230Vac
- Flashing Options: Autolampeggio (2Hz) or with externally driven flash
- J1 Settings: C = Flashing externally managed, F = Flashing automatically managed
- STO1: Bracket for wall or pole mount
- FUSE: 1A Fuse
Product Usage Instructions
Power Supply Connection
Connect the power supply to the appropriate voltage source (24Vac, 24Vdc, or 230Vac) following the specified connections for DC or AC.
Flashing Settings
Use jumper J1 to select the flashing mode. Insert the bridge for:
- C = Flashing externally managed
- F = Flashing automatically managed
Mounting Instructions
Mount the flashlight in a vertical position with the dome upward. Ensure there is no voltage in the cables before installation.
OPERATING AND INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATIONS
- Working with auto flash (2 Hz) or with externally driven flash (selectable with jumper)
- Power of the device by choosing the power supply terminal, it can be 24Vac, 24Vdc or 230Vac
- In-line fuse
DIAGRAM
- 220Vac 230 Vac power-supply
- 24 V dc Connection for 24V DC power-supply
- 24 V ac Connection for 24V AC power-supply
- J1 Insert the bridge for:
- C = Flashing externally managed
- F = Flashing automatically managed
- STO1
Bracket for wall or pole mount - FUSE
1 A Fuse
Any connection to the board must be carried out by qualified people only after having disconnected the unit.
Mount the flashlight in a vertical position, dome upward and inserting the wires the provided holes.
FERPORT s.a.s. is not liable for damages due to incorrect connections and/or tampering of the receivers neither are such damages covered by guarantee
Via Chienti 6-20052 Monza, Italy – Tel. 039-734095 – Fax 039-734951
internet: http://wwww.ferport.it
e-mail: ferport@ferport.it
FAQ
What should I do if there is a power supply issue?
Check the power connections and ensure the correct voltage is supplied to the device. Verify the fuse is intact.
How can I change the flashing mode?
Use jumper J1 to switch between externally managed flashing (C) and automatically managed flashing (F).
Can I mount the device on a pole?
Yes, you can use the STO1 bracket for mounting on a pole or wall.
Documents / Resources
![]() |
FERPORT XLX22024L ARMAS Externally Driven Flash [pdf] Installation Guide XLX22024L ARMAS Externally Driven Flash, XLX22024L, ARMAS Externally Driven Flash, Externally Driven Flash, Driven Flash, Flash |