
FEIG MRM103 Mid Range Reader Module

MODELS

NOTE
With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guarantee for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to human health. To avoid damage, injury or death the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they are free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
Safety Instructions
- The device may only be used for the intended purpose designed by for the manufacturer.
- The operation manual should be conveniently kept available at all times for each user.
- Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
- The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device.
- Repairs may only be executed by the manufacturer.
- Installation, operation, and maintenance procedures have to be carried out by professional and qualified personnel.
- Use of the device and its installation must be in accordance with national legal requirements and local electrical codes.
- When working on devices the valid safety regulations must be observed.
- Before touching the device, the power supply must always be interrupted. Make sure that the device is without voltage by measuring. The fading of an operation control (LED) is no indicator for an interrupted power supply or the device being out of voltage!
NOTE:
- Wearers of pacemakers
- Although this device does not exceed the permissible limits for electromagnetic fields, you should keep a minimum distance of 25 cm between the device and your pacemaker and not stay in the immediate vicinity of the device or the antenna for long periods of time.
History of documentation
| Revision | Data | Description |
| 0e | August 2025 | Initial Version |
| 1e | October 2025 | Bug fix |
Supported documents
| No. | Supported documents | Doc.No. |
| [1] | Further Information https://www.feig.de/en/login/ | |
| [2] | Manual | H50420-xe-ID-B |
| [3] | Quick Start PR(M)103-USB | M50630-xde-ID-B |
| [4] | Quick Start MR(M)103-A | M50628-xde-ID-B |
| [5] | Quick Start MR103-E | M50629-xde-ID-B |
| [6] | Quick Start MR(M)103-USBC | M50627-xde-ID-B |
Explanation of symbols
| Symbol | Explanation |
| VDC/ |
Direct voltage symbol |
Performance feature
General Information
- All reader variants described here have been developed for contactless data exchange with transponders whose operating frequency is 13.56 MHz.
- The ID PR103 has an integrated antenna and works with a transponder-dependent, typical reading range of 20 cm. The reader is equipped with a USB interface for communication with the host.
- The ID MR103 variants are equipped with a connection for an external antenna and work with a transponder-dependent, typical reading range of 40 cm.
- The following interfaces are available for communication with the host: RS232, USB, USBC, Ethernet.
- The “Anticollision” function enables the simultaneous reading of up to 100 x ISO15693 or 20 x I-CODE1 transponders.
- The reader variants are available as a housing version and as a module version.
Reader type code
| Reader type | Version | Interface |
| 79 (Hex.: 0x4F) | A | RS232 |
| USB | USB 2.0 | |
| USBC | USBC | |
| E (Ethernet) | LAN |
Tab 1: Reader type
Overview

Reader versions
| Reader Type | Firmware | Version | Interface |
| ID MR103-USB | Standard | Housing | USB |
| ID MRM103-USB | Standard | Modul | USB |
| ID MR103-USBC | Standard | Housing | USBC |
| ID MR103-A | Standard | Housing | RS232 |
| ID MRM103-A | Standard | Modul | RS232 |
| ID MR103-E | Ethernet | Housing | LAN |
| ID PR103-USB | Standard | Housing | USB |
| ID PRM103-USB | Standard | Modul | USB |
Tab 2: Reader version
Supported operating modes

Tab 3: Operating Mode
Scope of delivery
- 1 x Device
- 1 x Quick Start document
Cyber Security
Cyber Security (MR103-E)
Commissioning of the device
IMPORTANT NOTICE In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), the following points must be taken into account for the product ID MR103-E:
- When using the network interface (Ethernet), it may be necessary to create at least one user to enable various functions such as changing the configuration. The user and the password MUST be set by the person who puts the device into operation on first use before it is logically connected to a network or by an authorized entity within a network where access is limited to authorized entities.
- When security and/or network assets (keys, certificates, ethernet configuration parameters) are transferred via network interface (Ethernet) TLS encryption must be used to secure the communication.
Cyber Security related Firmware Updates
IMPORTANT NOTICE: In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), you are required to register in the FEIG download area under https://www.feig.de/en/ and subscribe to notifications for cybersecurity-related firmware and software updates for the product ID MR103-E.
Firmware downgrade
IMPORTANT NOTICE: A firmware downgrade to older major release versions is not possible in order to prevent old major versions with known cyber security vulnerabilities from being executed on the device.
Installation
Housing version
- The readers are designed for indoor applications.
- Wall and under-counter mounting are possible with the optionally available mounting kit.
See 8.1 Wall mounting or under-counter mounting
Dimensions

Modul version
The Module version is intended for installation in customer housings.
Modul dimension [mm]

Interface Overview and Connections
Depending on the reader variant, different connections and interfaces are available.

Interface designation
| Connector | Description |
| X1 | Power supply 12 – 24V DC/ ± 10% |
| X2 | RS232 & Power supply 12 – 24V DC/ ± 10% |
| X3 | USB / USBC |
| X4 | 10/100Tbase Network interface (RJ45) LAN |
| ANT 1 | Connector ext. antenna (Impedance Ω) |
Tab 4: Connector description
Antenna connection ANT1
There is an SMA socket on the circuit board or on the housing for connecting the external antenna.
NOTE:
- The antenna must be adjusted to the value 50 Ω (50 Ω L 15°).
- The optimum operating quality of the antenna should be in the range QB = 10…20. To determine the operating quality, the antenna must be supplied with a 50 Ω source, e.g. a network analyzer or a frequency generator.
- When connecting an antenna, make sure that it does not exceed the permissible limit values of the national regulations regarding radio equipment.
- The maximum tightening torque of the SMA sockets is 0.45 Nm.
DC Voltage on antenna connector ANT1
A DC voltage can be applied from the reader to the ANT1 antenna connection. This DC voltage can be used to supply an LED, for example.
NOTE:
- The DC voltage is only designed for low currents. The DC voltage (6,9 V± 1 V) can be loaded up to a maximum of 5mA.
- Only antennas that are suitable for DC voltage and do not short-circuit the DC voltage may be connected.
- When connecting other devices (e.g. VSWR meters), make sure that they are also suitable for DC voltage.
- This DC voltage is not suitable for supplying the automatic antenna tuner ID ISC.DAT.
Overview Power supply
| ID PR(M)103-USB | X3 | 5 VDC / 500 mA (via USB) |
| ID MR(M)103-A | X2 | Pin 1 = GND
Pin 2 = RxD Pin 3 = TxD Pin 4 = GND Pin 5 = 12 bis 24V DC/ |
| ID MR103-E | X1 | External Power Supply Unit (12 bis 24V DC/ |
| ID MR(M)103-USB | X1 | External Power Supply Unit (12 bis 24V DC/ |
| ID MR103-USBC | X3 | 5V DC/ |
Tab 5: Power Supply
X1: External Power Supply*
- The device may only be supplied by a power source in accordance with EN 62368-1 Chapter Q.1 Power sources of limited power or with a power supply unit certified in accordance with NEC Class 2/LPS.
- For more information on available power supply units, see Accessories.
Connector for external Power Supply Unit
X2: RS232 Interface (ID MR103-A)
The transmission parameters can be configured via software protocol.
Connector X2 / Pin Assignment
X3: USB-Interface (ID PR103-USB / ID MR103-USB, USBC)
The USB interface is connected via socket X3 (ID PR103-USB / ID MR103-USB / -USBC). The assignment is standardized. The data rate of the reader is limited to 12 Mbit (USB Full Speed). A standard USBC cable can be used.
NOTE: Maximum length of the USB cab e: ≤ 3 m
X4: Ethernet-Interface (ID MR103-E)
- The reader has an integrated 10/100 base-T network interface with standard RJ-45 connection. The connection is made via X4 and has automatic crossover detection in accordance with the 1000BASE-T standard.
- For structured cabling, at least CAT5 category cables should be used. This guarantees problem-free operation at 10 Mbps or 100 Mbps.
- A prerequisite for using the TCP/IP protocol is that each device on the network has its own IP address. All readers have a factory-set IP address.
- The transmission parameters can be configured via software protocol.
| Network | Address |
| IP-Address | 192.168.10.10 |
| Subnet-Mask | 255.255.255.0 |
| Port | 10001 |
| DHCP | ON |
Tab 8: Default setting Ethernet Interface
NOTE:
- The reader has a DHCP-capable TCP/IP interface.
- A shielded STP (shielded and twisted pair) CAT5 cable must be used.
Operating and Display Elements
Default settings for LED indication

Radio Approvals
Declaration of conformity (CE)
- CE Declaration of Conformity
- Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID PRM103 / ID MRM103 is in compliance with Directive 2014/53/EU.
- The full text of the EU Declaration of Conformity is available at the following internet address: https://www.feig.de/en/service/.
USA (FCC) and Canada (IC)
NOTE: The RFID reader ID PR103 / MR103 contains the RFID module ID PRM103 / MRM103.
| Product name: | ID PR103 / MR103 |
| FCC ID: IC: | PJMPRM103 PJMMRM103 6633A-PRM103 6633A-MRM103 |
| Notice for
USA and Canada |
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal Communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. |
| Radiofrequency radiation exposure Information: | This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. |
NOTE: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
Installation with FCC / IC Approval
FCC-/IC-NOTICE: To comply with FCC-Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States / Canada.
Label Information
- UThe following information must be placed at the outer side of the housing in which the reader is mounted.
- Contains FCC ID PJMPRM103 Contains FCC ID PJMMRM103
- Contains IC: 6633A-PRM103 Contains IC: 6633A-MRM103
Technical Data
| Mechanical Data | |
| Housing PR103 / MR103 | Plastic ABS |
| Weight
PR103 MR103 |
150 g
150 g |
| Dimension PR103 / MR103
(w x h x d) |
(145 x 85 x 22) mm |
| Dimension PR103 / MR103 Module
(w x h x d) |
(145 x 77 x 17) mm |
| Weight Modul | 56 g |
| Protection class PR103 / MR103 | IP 30 |
| Color housing | RAL 9018 (white) |
| Electrical Data | |
| Power Supply
· ID PR103-USB · ID MR103-A/-USB · ID MRM103-A/-USB · ID MR103-E · ID MR103-USBC |
· 5V DC · 12V DC up to 24V DC · 12V DC up to 24V DC · 12V DC up to 24V DC · Via USB-Type-C (Current at 1.5A) |
| Power consumption
ID PR103-USB ID MR103-A, USB, USBC, E |
max. 2.5W max. 6W |
| Antenna
PR(M)103-USB |
integrated |
| Antenna connector MR(M)103 | 1x SMA-socket (50 W) |
| Supply voltage on antenna output
MR103 |
6,9V DC ± 1V (5 mA) Antenna output |
| Operating frequency
PR103-USB ID MR103-A, USB, USBC, E |
13,56 MHz |
| Transmitting power
ID PR103-USB ID MR103-A, USB, USBC, E |
0.6W ± 2dB
1,2W ± 1dB 1,5W ± 1dB |
| Supported transponder | ISO15693, (ISO 18000-3 MODE 1), I-CODE1 |
| Reader modes
ID PR(M)103-USB ID MR(M)103-A, USB, USBC, ID MR(M)103-E |
ISO Host Mode, Scan Mode ISO Host Mode, Scan Mode
ISO Host Mode, Notification Mode |
| 1 x LED | 1 x multicolor LED; (green, blue, red) |
| Interfaces
· ID PR(M)103-USB · ID MR(M)103-A |
· USB
· RS232 |
| · ID MR(M)103-USB
· IS MR(M)103-USBC · ID MR(M)103-E |
· USB
· USB · Ethernet (TCP/IP) |
| Feature | Short-circuit detection (antenna)
Temperature monitoring |
| Environmental conditions | |
| Temperature range | -25°C to +55°C
-40°C to +85°C |
| Operation Storage | |
| Relative air humidity | 5% – 95% (noncondensing) |
| Vibration | EN60068-2-6
10 Hz bis 150 Hz: 0,075 mm / 1 g |
| Shock | EN60068-2-27
Acceleration: 30 g |
| Approvals | |
| Radio approval | · EN 300 330
· FCC 47 CFR-Part 15 · RSS-Gen Issue 1, RSS-210 |
| · Europa / UK
· USA · Canada |
|
| EMV | EN 301 489 |
| Safety and Health | EN 62368-1
EN 50364 EN 18031 |
| Low voltage Human Exposure
Cyber Security (MR103-E) |
|
Accessories
| Order No. | Type | Description | |
| 1688.002.00 | ID NET.12V-B-EU Power Supply Unit 12V | Supply unit 100 – 240V AC, (Angled plug, EU),
Output: 12V DC/ ; 50Hz / 60Hz, 700mA |
|
| 3886.000.00 | ID NET.12V-B-GB Power Supply Unit 12V | Supply unit 100 – 240V AC, (Angled plug, GB) | |
| 3887.000.00 | ID NET.12V-B-US Power Supply Unit 12V | Supply unit 100 – 240V AC, (Angled plug, US) | |
| 7224.000.00 | ID MS.MR103/PR103-A | Wall mounting or under-counter mounting | |
| 7102.000.00 | ID CAB.RS-T | Cable for RS232 and Power Supply (ID MR103-A) | |
| 7103.000.00 | ID CAB.USB-AC | USB Interface cable, USB-A auf USBC | |
| 7104.000.00 | ID CAB.USB-CC | USB Interface cable, USBC auf USBC | |
| External Antennas | |||
| 1663.000.00 | ID ISC.ANT340/240-A | Dim.: Protection.: | 340mm x 240mm x 9mm IP20 |
| 2396.000.00 | ID ISC.ANT340/240-B | External antenna without housing | |
| 3249.000.00 | ID ISC.ANT310/310-A | Dim.: Protection.: | 318mm x 338mm x 30mm IP65 |
| 3512.000.00 | ID ISC.ANTS370/270 | Dim.: Protection.: | 370mm x 270mm x 27mm IP20 |
| 6612.000.00 | ID ANT240/180-A | Dim.: Protection: | 40mm x 180mm x 13mm IP30 |
| 6616.000.00 | ID ANTS240/180-A | Dim.: Protection: | 240mm x 180mm x 15mm IP30 |
| 1968.000.00 | ID ISC.ANT100/100-A | External antenna without housing Dim.: 40mm x 30mm x 6mm | |
| 1967.000.00 | ID ISC.ANT40/30-A | External antenna without housing
Dim.: 100mm x 100mm x 6mm |
|
Tab 10: Accessories
Wall mounting or under counter mounting
- Remove the screws on the back of the reader.
- The mounting brackets are fastened with the previously removed screws.
- They can also be mounted rotated by 90° as an option.

Note: The mounting kit “ID MS.MR103/PR103-A” includes the four mounting brackets (See Accessories).
Serial Data Cable ID CAB.RS-T
| PIN | Signal | Farbe / Color | X2 |
| 1 | GND | Yellow | ![]() |
| 2 | RxD | Orange | |
| 3 | TxD | Brown | |
| 4 | GND | Black | |
| 5 | 12 bis 24V DC/ |
Red |

- Document: Installation
- Id-Nr. Document Version: M50720-0e-ID-B
- Date: 30.10.25
CONTACT INFORMATION
- © Copyright
- All brand names, product names or trademarks mentioned are the property of their respective owners.
- FEIG ELECTRONIC GmbH
- Industriestraße 1a
- 35781 Weilburg, Germany
- Tel.: +49 6471 3109-0
- Homepage: https://www.feig.de/en/
- Email: identification-support@feig.de.
FAQs
- Can I make modifications to the device?
- No, unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
- Who can perform repairs on the device?
- Repairs may only be executed by the manufacturer.
- What should I do before handling the device?
- Before touching the device, the power supply must always be interrupted. Make sure that the device is without voltage by measuring. The fading of an operation control (LED) is no indicator for an
- interrupted power supply or the device being out of voltage!
- Where can I find the latest version of the manual?
- With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. For the most current information, it is recommended to contact FEIG ELECTRONIC GmbH.
Documents / Resources
![]() | MRM103 Mid Range Reader Module |
References
- CAB.RScab.rs
- Doc.Nodoc.no
- mailto:Identification-support@feig.defeig.de
- nord.denord.de
- feig.de/en/www.feig.de
- feig.de/en/login/www.feig.de
- feig.de/en/service/www.feig.de
- User Manualmanual.tools


