Specifications:

  • Product Name: 6 Way Master Switch MINI Controller
  • Input Voltage: 10-30VDC
  • Max Current: 40A input, 10A output on P1 and P2, 5A output on
    P3, P4, P5, P6
  • Color Coding: RED (P1), BLACK (P2), YELLOW (P3), BLUE (P4),
    Green (P5), GREY (P6), PURPLE (White)

Product Usage Instructions

1. Wiring Instructions:

Connect the corresponding wires to the designated terminals as
follows:

  • P1: Input 10-30VDC, Max 40A
  • P2-P6: Output with varying maximum currents as specified

2. ENTER Programming Mode:

2.1: Latching/Momentary Setting:

  1. Ensure the controller is switched OFF.
  2. Hold the ON/OFF master switch button and push the desired
    switch from ON/OFF latching to Momentary activation.
  3. Confirmation is indicated by an audible tone.
  4. Repeat for each switch.

2.2: Master/Slave Setting (Group mode):

  1. Power on the controller and set the master button by holding it
    until a BEEP sound.
  2. Press the button to be set as the slave.
  3. To cancel, hold the master button until a BEEP sound and then
    press the slave button.
  4. Note: After successful configuration, the slave button can
    still be controlled independently.

3. Mounting:

3.1: 3M Sticker mount:

Use the provided 3M VHB Sticker for mounting.

3.2: Bracket mount:

Mount using a 1/4 inch threaded hole bracket.

FAQ

Q: What should I do if the button is flashing?

A: If the button is flashing, it is set as a slave. If it is
constantly on, it is set as a master. If a button is programmed as
momentary, it cannot be used as a slave; it will be constantly on.
Pressing the master button (momentary programmed) will not switch
the button to flashing.

“`

6 Way Master Switch MINI Controller
1.Wiring Instructions

P1

P2

P3

P4

P5

P6

ON/OFF

RED BLACK YELLOW BLUE Green GREY PURPLE White

INPUT 10-30VDC+/MAX 40A INPUT GROUND P1 OUTPUT /MAX 10A P2 OUTPUT /MAX 10A P3 OUTPUT /MAX 5A P4 OUTPUT /MAX 5A P5 OUTPUT /MAX 5A P6 OUTPUT /MAX 5A

2.ENTER Programming Mode

2.1:Latching/Momentary Setting
l To enter programming mode ensure that the controller is switched OFF. l PRESS and HOLD the ON/OFF master switch button,whilst depressed,push the corresponding Switch that you would like to program from ON/
OFF latching to Momentary activation which will be confirmed by an audible tone. l Repeat this procedure to program each of the 4 available switches.

Beep
2.2:Master/Slave Setting(Group mode) l Power on the controller, press and hold the button to be set as the master, keep it until a BEEP sound. Then press the button to be set as the
slave. l Cancellation: Power on, press and hold the master button, keep it until a BEEP sound, then press the slave button to cancel l Remarks: After set successfully of Master/Salve button, the salve button can still be controlled independently.
NOTE: If the button is flashing the button is set as slave, if the button is constantly on the button is set as slave. If a button is programmed as momentary the button can t be used as slave, the button will be constantly on and if you press the master button (Momentary programmed) the button will not switch to flashing.

Master

Master

3.Mounting
3.1: 3M Sticker mount
3M VHB STICKER

Beep

Master

Slave