SC7X 6 Way Master Switch MINI Controller
“
Product Information
Specifications:
- Product Name: 6 Way Master Switch MINI Controller
- Input Voltage: 10-30VDC
- Max Current: 40A input, 10A output on P1 and P2, 5A output on
P3, P4, P5, P6 - Color Coding: RED (P1), BLACK (P2), YELLOW (P3), BLUE (P4),
Green (P5), GREY (P6), PURPLE (White)
Product Usage Instructions
1. Wiring Instructions:
Connect the corresponding wires to the designated terminals as
follows:
- P1: Input 10-30VDC, Max 40A
- P2-P6: Output with varying maximum currents as specified
2. ENTER Programming Mode:
2.1: Latching/Momentary Setting:
- Ensure the controller is switched OFF.
- Hold the ON/OFF master switch button and push the desired
switch from ON/OFF latching to Momentary activation. - Confirmation is indicated by an audible tone.
- Repeat for each switch.
2.2: Master/Slave Setting (Group mode):
- Power on the controller and set the master button by holding it
until a BEEP sound. - Press the button to be set as the slave.
- To cancel, hold the master button until a BEEP sound and then
press the slave button. - Note: After successful configuration, the slave button can
still be controlled independently.
3. Mounting:
3.1: 3M Sticker mount:
Use the provided 3M VHB Sticker for mounting.
3.2: Bracket mount:
Mount using a 1/4 inch threaded hole bracket.
FAQ
A: If the button is flashing, it is set as a slave. If it is
constantly on, it is set as a master. If a button is programmed as
momentary, it cannot be used as a slave; it will be constantly on.
Pressing the master button (momentary programmed) will not switch
the button to flashing.
“`
6 Way Master Switch MINI Controller
1.Wiring Instructions
P1
P2
P3
P4
P5
P6
ON/OFF
RED BLACK YELLOW BLUE Green GREY PURPLE White
INPUT 10-30VDC+/MAX 40A INPUT GROUND P1 OUTPUT /MAX 10A P2 OUTPUT /MAX 10A P3 OUTPUT /MAX 5A P4 OUTPUT /MAX 5A P5 OUTPUT /MAX 5A P6 OUTPUT /MAX 5A
2.ENTER Programming Mode
2.1:Latching/Momentary Setting
l To enter programming mode ensure that the controller is switched OFF. l PRESS and HOLD the ON/OFF master switch button,whilst depressed,push the corresponding Switch that you would like to program from ON/
OFF latching to Momentary activation which will be confirmed by an audible tone. l Repeat this procedure to program each of the 4 available switches.
Beep
2.2:Master/Slave Setting(Group mode) l Power on the controller, press and hold the button to be set as the master, keep it until a BEEP sound. Then press the button to be set as the
slave. l Cancellation: Power on, press and hold the master button, keep it until a BEEP sound, then press the slave button to cancel l Remarks: After set successfully of Master/Salve button, the salve button can still be controlled independently.
NOTE: If the button is flashing the button is set as slave, if the button is constantly on the button is set as slave. If a button is programmed as momentary the button can t be used as slave, the button will be constantly on and if you press the master button (Momentary programmed) the button will not switch to flashing.