expella VENTILATION Series Linear Slot Diffuser
Product Information
Product Specifications:
- Model: Linear Slot Diffuser
- Code: 8168 (600mm), 8170 (780mm)
- Dimensions: 1LSG600 – 580mm, 1LSG780 – 770mm
Product Usage Instructions
Installation:
- Cut the ceiling to the required size.
- Feed the spigot into the ceiling cavity through the hole.
- Connect the duct to the spigot using duct tape and cable tie.
- Feed the plenum box into the ceiling cavity through the hole.
- Secure the spigot to the plenum box using an M5 screw.
- Install the facia into the plenum.
- (Optional) Seal any gaps with a small bead of gap sealant matching the ceiling colour.
Rough-in:
Install an inline fan system with 150mm flexible ducting routed from the fan intake to the location of the Linear Slot Grille. Allow for additional ducting as needed.
Additional Tips:
- Make sure to check for clearance of the ceiling framing before installation.
- Fold up the spring and feed it through the opening in the plenum to engage the facia securely.
Frequently Asked Questions (FAQ):
- Q: How can I ensure a proper fit during installation?
A: Double-check measurements and ensure there is enough clearance for all components within the ceiling cavity. - Q: Do I need to seal any gaps after installation?
A: It is recommended to seal any visible gaps using a matching gap sealant for a clean finish.
PARTS INCLUDED
Description |
Qty |
|
Facia (780B) | 1 | |
Facia (600B) | 1 | |
Plenum Box | (780B) | 1 |
Plenum Box (600B) | 1 | |
Spigot, Oval (150mm flex duct) | 1 | |
Screw, Button Head Cap, M5 x 16 | 1 |
INSTALLATION
Rough-in
Install an inline fan system with 150mm flexible ducting routed from the intake of the fan to the location of the Linear Slot Grille. Allow a small amount of additional ducting.
- Cut ceiling
WARNING: Check for clearance of ceiling framing.
- Feed spigot into ceiling cavity, through hole
- Connect the duct to the spigot using duct tape and cable tie
- Connect the duct to the spigot using duct tape and cable tie
- Connect spigot to plenum box
- Secure the spigot to the plenum with an M5 screw
- Install facia into plenum.
- Fold up spring. Feed spring through an opening in the plenum.
- Release the spring to engage the facia into the plenum.
- Seal Gap (optional)
For a premium finish, use a small bead of gap sealant (colour to match the ceiling) where the facia meets the ceiling.
DIMENSIONS
Model |
Cut out | Plenum Box |
Facia |
|||||||||
A | B | C | D | E | F | G | H | I | J | K | L | |
600mm | 580 | 65 | 695 | 197 | 53 | 67 | 106 | 118 | 537 | 598 | 22 | 78 |
780mm | 770 | 65 | 888 | 197 | 53 | 57 | 96 | 110 | 718 | 775 | 22 | 78 |
WARRANTY
2-year warranty from the date of purchase.
CONTACT US
- 30 Mill Road, Whanganui
- 0800 728 662
- sales@newtech.co.nz.
- www.newtech.co.nz.
Documents / Resources
![]() |