ESL VISION IntelliSense Series Backlit Panel
Product Information
Specifications:
- Product Name: INTELLISENSETM SERIES Panel
- Installation Type: Recessed
- Control Type: 0-10V Dimming
- Sensor Compatibility: Approved sensors
Product Usage Instructions
Recessed Installation:
- Lift up the four mounting clips on the sides of the fixture and twist into position.
- Insert into ceiling grid. Use protective brackets as needed for safety.
Sensor Installation:
- Remove the sensor plate.
- Remove the flat cable from the back of the plate.
- Insert the cable terminals into the approved sensor.
- Snap the sensor into the fixture securely.
CCT & Wattage Adjustment:
- Adjust Kelvin and wattage using the dip switches located on the driver.
- Select the desired Kelvin and wattage by adjusting the dip switch.
Cable Kit Mounting:
- Pull the sleeve on the end of Cable A through the provided flange and fix the flanges onto the ceiling with self-tapping screws.
- Insert the end of Cable A into the wire rope gripper attached to Cable B, adjust to desired height, and angle using the wire rope lock.
- Hook the fixture up to the swivel lobster clasp attached to Cable B and make final adjustments.
- Connect LED Driver to power.
WARNING
- To avoid electric shock, disconnect power at source prior to installation.
- The installation should be performed by qualified electricians or lighting technicians.
- Before conducting any installation, maintenance, or removal, disable all power.
- Do not touch the fixture while it is in service.
- If there is any problem with the fixture, turn off power and DO NOT attempt repair unless you are a qualified technician or the customer service member.
Recessed Installation
- Lift up the four mounting clips on the sides of the fixture and twist into position.
- Remove enclosure cover and remove knockout for AC input and 0–10V control lines. Install fittings in knockout holes if needed.
- Connect the AC line (L, N and GND) to the LED Driver using 18–14AWG wire as shown in Wiring Diagram 2. When connecting a 0-10V dimming controller, wires must be run through a separate knockout hole equipped with appropriate electrical fittings.
- Insert into ceiling grid. Use protective brackets as needed for safety.
Wiring Diagram
Sensor Installation
An approved sensor may be installed before or after fixture installation.
- Remove the sensor plate.
- Remove the flat cable from the back of the plate.
- Insert the cable terminals into the approved sensor.
- Snap the sensor into the fixture securely.
CCT & Wattage Adjustment
- Kelvin and wattage can be adjusted using the dip switches located on the driver.
- Select the desired kelvin and wattage by adjusting the dip switch.
Cable Kit Mounting
- Pull the sleeve on the end of Cable A through the provided flange and make sure the end cap is positioned in the flange. Fix the flanges onto the ceiling with selftapping screws.
- Insert the end of Cable A into the wire rope gripper attached to Cable B, then adjust Cable A to the desired height by pressing the wire rope lock and adjusting to the desired angle.
- Hook the fixture up to the swivel lobster clasp attached to the two ends of cable B and make the final adjustments.
- Connect LED Driver to power.
888.493.5559
info@eslvision.com
www.eslvision.com
Copyright © 2024 ESL Vision, LLC. All rights reserved. Rev: 07/19/24
Frequently Asked Questions
Q: Can I adjust both Kelvin and wattage settings?
A: Yes, you can adjust both Kelvin and wattage settings using the dip switches on the driver.
Q: Is it necessary to disconnect power before installation?
A: Yes, it is essential to disconnect power at the source prior to installation to avoid electric shock.