ECB02M230 2 Heating Circuits Module
Specifications
- Model: ECB02M230
- Product Type: Control Box
- Heating Circuits: 2
- Power Supply: 230 V AC 50 Hz 6(1)A
- Dimensions: 150 x 90 x 35 mm
Product Description
The ECB02M230 Control Box is designed for managing heating
circuits in a heating system. It features two circuits for
controlling the main pump and boiler, ensuring efficient heating
control.
Installation
- Ensure the control box is disconnected from the power supply
before any installation or maintenance. - Connect the power supply (230 V AC) ensuring correct
polarity. - Connect the main pump and boiler outputs to their respective
devices following the provided instructions.
Operation
The control box activates the main pump and boiler outputs based
on signals received from room controllers. The green LED indicates
when the outputs are activated. Ensure proper functioning as per
the boiler’s manual.
Connection Contacts
The control box allows for various thermostat connections,
including battery thermostats, 230V thermostats, and wireless
thermostat receivers. Follow the provided circuit connection
contacts for each type of thermostat.
Fuse Replacement
Replace the fuse with a ceramic tube slow blow 250V ROHS fuse
(5×20 mm) only when the control box is disconnected from the power
supply. Locate the main fuse under the housing cover next to the
power supply terminals.
Safety Information
For additional protection requirements during installation, the
installer must ensure compliance with safety standards and
regulations.
Power Supply
The red LED indicates a successful connection to the power
supply. Verify proper installation and connection for safe
operation.
FAQ
Q: What should I do if the green LED does not light up?
A: Check the connections of the main pump and boiler outputs.
Ensure the signals from room controllers are reaching the control
box.
Q: Can I use this control box for underfloor heating
systems?
A: Yes, additional thermal protection can be used for underfloor
heating. Follow the instructions provided for proper
integration.
CONTROL BOX
ECB02M230 | 2 Heating circuits module
Quick Guide
Ver. 1.0 Release date: II 2024
Soft: v1.3
Producer: Engo Controls S.C. 43-262 Kobielice
4 Rolna St. Poland
Distributor: QL CONTROLS Sp z o.o. Sp. k.
43-262 Kobielice 4 Rolna St. Poland
www.engocontrols.com
Introduction
The heating circuit module makes it possible to operate two independent heat zones to which temperature controllers and circulation pumps are connected. It is used in typical single-family housing, where there are divisions into 2 heating circuits (e.g. 1 first floor circuit and 2 floor circuit). Then the signal coming from any of the heating circuits activates the outputs to the main circulation pump and the heat source in the controller. The integrator can also be used for small (e.g. two-zone) floor heating systems.
Product compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, RoHS directive 2011/65/EU.
Safety information
Use in accordance with national and EU regulations. Device is intended for indoor use only in dry conditions. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations. Before attempting to setup and install, make sure that ECB02M230 is not connected to any power source. Installation must be carried out by a qualified person. Incorrect installation may cause damage to the wiring centre. The ECB02M230 should not be installed in areas where it may be exposed to water or damp conditions.
PLEASE NOTE: For the entire installation, there may be additional protection requirements, which the installer is responsible for maintaining.
Technical Information
Power Supply Total Load Max
Outputs:
Dimensions [mm]
230 V AC 50 Hz 6(1)A
Pump230V AC max. 3(1)A Boiler (NO/COM/NC) max. 6(1)A
150 x 90 x 35
Control Box description
4
3
2
1
NC COM NO N L3 PE PE PE PE N L
BOILER
MAIN PUMP
POWER SUPPLY
FUSE 6.3A)
POWER CIRCUIT 1
1
LED
LED
CIRCUIT 2 PUMP/BOILER
2
7
LED
LED
NL
CIRCUIT 1
TK TK L1 N N L
ECB02M230
CIRCUIT 2
TK TK L2 N
5
1. Cartridge fuse 5 x 20 mm T6,3A 2. Power supply (AC 230V) 3. Main pump control output (AC 230V) 4. Boiler control output (volt free) 5. Circuit 1 – connection contacts 6. Circuit 2 – connection contacts
6
7. LED diodes indicators: · power supply connection · circuit 1 is activated · circuit 2 is activated · boiler and main pump is activated
Fuse
Please note: Replacement of the fuse to be carried out only when the control box is disconnected from power supply (230 V ~).. Main fuse is located under the housing cover next to power supply terminals and secures the control box and the devices connected to it. Use ceramic tube slow blow 250 V ROHS fuses (5×20 mm) with nominal max current 6,3A. To replace fuse remove the fuse holder with a flat screwdriver and pull out the fuse.
Power supply
230 V AC L N
PE N L POWER SUPPLY
Power supply for wiring centre is 230 V ~ 50Hz. Installation features: · three-wire, · made in accordance with applicable regulations.
The red LED indicates that the wiring centre is connected to the power supply.
Boiler and main pump outputs
The MAIN PUMP and BOILER outputs are used to control the main circulating pump and the heat source in the heating system. The outputs are turned on when a heating signal is received from any room controller connected to the integrator. The outputs are turned off when none of the controllers sends a signal for heating.
P3
Boiler ON/OFF contacts (according to the boiler’s manual)
NC COM NO N L3 PE
MAIN PUMP
230V AC output, max 3A.
BOILER
Voltage-free contacts (NO/COM/NC).
230V
The green LED indicates that the BOILER & MAIN PUMP output is activated.
Circuit connection contacts
a) – Connecting a battery thermostat (with voltage-free COM / NO contacts)
b) – 230V thermostat connection (with SL – 230V voltage output)
NL
NL
COM
NO
N
L
SL
c) – 230V thermostat connection (with COM / NO voltage-free contacts)
d) – Wireless thermostats receiver connection (with COM / NO voltage-free contacts)
NL
NL
N
L COM SL
N
L COM SL
868MHz
Circuit connection contacts
If the integrator was used for underfloor heating, additional thermal protection can be used (e.g., a bimetallic touch thermostat).
If the temperature is exceeded, the thermal protection will turn off the circulation pump in the circuit in question
If thermal protection is not used, a short circuit should be used in its place
TK TK
TK TK
NC COM
PIPE THERMOSTAT
Circulation pump/actuator output
L1 N
L1 N
lub
N
L
PE
N
L
PE
M 230V
The green LED1, LED2 indicates that the circulation pump/actuator output is activated
COM COM
5. Wiring diagrams Below are sample wiring diagrams of the integrator. Hydraulic diagrams are illustrative and are not a substitute for the design of the CO system.
a) – Connection of 2 heating circuits
Pump
P1
First floor
*boiler connection
Pump
P3
Clutch
Mixing valve
Pump
P2
RT1
Ground floor
RT2
L AC 230V N PE
PE P3
NL
*boiler connection
NC COM NO N L3 PE PE PE PE N L
BOILER MAIN PUMP POWER SUPPLY
ECB02M230
CIRCUIT 1
CIRCUIT 2
NL
TK TK L1 N N L
TK TK L2 N
NL
LN
P1 NO
PE COM
LN
P2
PE
NO
868MHz
RT1
RT2
b) – Connection of 2 underfloor heating zones
Mixing valve
Mainfold
P3
M1 M1 M2 M2
*boiler connection
L AC 230V N PE
*boiler connection
RT1
RT2
PE P3
NL
NC COM NO N L3 PE PE PE PE N L
BOILER MAIN PUMP POWER SUPPLY
ECB02M230
CIRCUIT 1
CIRCUIT 2
NL
TK TK L1 N N L
TK TK L2 N
LN
M1 M
LN
M2 M
N L NO
COM NO
RT1
RT2
Boiler *- ON/OFF contacts (according to the boiler’s manual)
Mixing valve
Pump Valve actuator
Legend
Hydraulic coupling
Radiator heating Underfloor heating
– Fuse L, N – 230V AC power suply COM, NO, NC – Voltage-free output RT1 – Circuit 1 thermostat RT2 – Circuit 2 thermostat
P1 – Circuit 1 circulation pump P2 – Circuit 2 circulation pump P3 – Main pump M1 – Circuit 1 actuator M2 – Circuit 2 actuator
Documents / Resources
![]() |
ENGO CONTROLS ECB02M230 2 Heating Circuits Module [pdf] User Guide ECB02M230 2 Heating Circuits Module, ECB02M230 2, Heating Circuits Module, Circuits Module, Module |