ENGO CONTROLS ECB02M230 2 Heating Circuits Module User Guide

ECB02M230 2 Heating Circuits Module

Specifications

  • Model: ECB02M230
  • Product Type: Control Box
  • Heating Circuits: 2
  • Power Supply: 230 V AC 50 Hz 6(1)A
  • Dimensions: 150 x 90 x 35 mm

Product Description

The ECB02M230 Control Box is designed for managing heating
circuits in a heating system. It features two circuits for
controlling the main pump and boiler, ensuring efficient heating
control.

Installation

  1. Ensure the control box is disconnected from the power supply
    before any installation or maintenance.
  2. Connect the power supply (230 V AC) ensuring correct
    polarity.
  3. Connect the main pump and boiler outputs to their respective
    devices following the provided instructions.

Operation

The control box activates the main pump and boiler outputs based
on signals received from room controllers. The green LED indicates
when the outputs are activated. Ensure proper functioning as per
the boiler’s manual.

Connection Contacts

The control box allows for various thermostat connections,
including battery thermostats, 230V thermostats, and wireless
thermostat receivers. Follow the provided circuit connection
contacts for each type of thermostat.

Fuse Replacement

Replace the fuse with a ceramic tube slow blow 250V ROHS fuse
(5×20 mm) only when the control box is disconnected from the power
supply. Locate the main fuse under the housing cover next to the
power supply terminals.

Safety Information

For additional protection requirements during installation, the
installer must ensure compliance with safety standards and
regulations.

Power Supply

The red LED indicates a successful connection to the power
supply. Verify proper installation and connection for safe
operation.

FAQ

Q: What should I do if the green LED does not light up?

A: Check the connections of the main pump and boiler outputs.
Ensure the signals from room controllers are reaching the control
box.

Q: Can I use this control box for underfloor heating
systems?

A: Yes, additional thermal protection can be used for underfloor
heating. Follow the instructions provided for proper
integration.

CONTROL BOX
ECB02M230 | 2 Heating circuits module

Quick Guide

Ver. 1.0 Release date: II 2024
Soft: v1.3

Producer: Engo Controls S.C. 43-262 Kobielice
4 Rolna St. Poland

Distributor: QL CONTROLS Sp z o.o. Sp. k.
43-262 Kobielice 4 Rolna St. Poland

www.engocontrols.com

Introduction
The heating circuit module makes it possible to operate two independent heat zones to which temperature controllers and circulation pumps are connected. It is used in typical single-family housing, where there are divisions into 2 heating circuits (e.g. 1 first floor circuit and 2 floor circuit). Then the signal coming from any of the heating circuits activates the outputs to the main circulation pump and the heat source in the controller. The integrator can also be used for small (e.g. two-zone) floor heating systems.
Product compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, RoHS directive 2011/65/EU.
Safety information
Use in accordance with national and EU regulations. Device is intended for indoor use only in dry conditions. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations. Before attempting to setup and install, make sure that ECB02M230 is not connected to any power source. Installation must be carried out by a qualified person. Incorrect installation may cause damage to the wiring centre. The ECB02M230 should not be installed in areas where it may be exposed to water or damp conditions.
PLEASE NOTE: For the entire installation, there may be additional protection requirements, which the installer is responsible for maintaining.

Technical Information
Power Supply Total Load Max
Outputs:
Dimensions [mm]

230 V AC 50 Hz 6(1)A
Pump230V AC max. 3(1)A Boiler (NO/COM/NC) max. 6(1)A
150 x 90 x 35

Control Box description

4

3

2

1

NC COM NO N L3 PE PE PE PE N L

BOILER

MAIN PUMP

POWER SUPPLY

FUSE 6.3A)

POWER CIRCUIT 1

1

LED

LED

CIRCUIT 2 PUMP/BOILER

2

7

LED

LED

NL

CIRCUIT 1
TK TK L1 N N L

ECB02M230
CIRCUIT 2
TK TK L2 N

5
1. Cartridge fuse 5 x 20 mm T6,3A 2. Power supply (AC 230V) 3. Main pump control output (AC 230V) 4. Boiler control output (volt free) 5. Circuit 1 – connection contacts 6. Circuit 2 – connection contacts

6
7. LED diodes indicators: · power supply connection · circuit 1 is activated · circuit 2 is activated · boiler and main pump is activated

Fuse
Please note: Replacement of the fuse to be carried out only when the control box is disconnected from power supply (230 V ~).. Main fuse is located under the housing cover next to power supply terminals and secures the control box and the devices connected to it. Use ceramic tube slow blow 250 V ROHS fuses (5×20 mm) with nominal max current 6,3A. To replace fuse remove the fuse holder with a flat screwdriver and pull out the fuse.
Power supply
230 V AC L N
PE N L POWER SUPPLY
Power supply for wiring centre is 230 V ~ 50Hz. Installation features: · three-wire, · made in accordance with applicable regulations.
The red LED indicates that the wiring centre is connected to the power supply.

Boiler and main pump outputs
The MAIN PUMP and BOILER outputs are used to control the main circulating pump and the heat source in the heating system. The outputs are turned on when a heating signal is received from any room controller connected to the integrator. The outputs are turned off when none of the controllers sends a signal for heating.
P3
Boiler ON/OFF contacts (according to the boiler’s manual)

NC COM NO N L3 PE
MAIN PUMP
230V AC output, max 3A.

BOILER
Voltage-free contacts (NO/COM/NC).

230V

The green LED indicates that the BOILER & MAIN PUMP output is activated.

Circuit connection contacts
a) – Connecting a battery thermostat (with voltage-free COM / NO contacts)

b) – 230V thermostat connection (with SL – 230V voltage output)

NL

NL

COM

NO

N

L

SL

c) – 230V thermostat connection (with COM / NO voltage-free contacts)

d) – Wireless thermostats receiver connection (with COM / NO voltage-free contacts)

NL

NL

N

L COM SL

N

L COM SL

868MHz

Circuit connection contacts
If the integrator was used for underfloor heating, additional thermal protection can be used (e.g., a bimetallic touch thermostat).

If the temperature is exceeded, the thermal protection will turn off the circulation pump in the circuit in question

If thermal protection is not used, a short circuit should be used in its place

TK TK

TK TK

NC COM
PIPE THERMOSTAT

Circulation pump/actuator output

L1 N

L1 N

lub

N

L

PE

N

L

PE

M 230V
The green LED1, LED2 indicates that the circulation pump/actuator output is activated

COM COM

5. Wiring diagrams Below are sample wiring diagrams of the integrator. Hydraulic diagrams are illustrative and are not a substitute for the design of the CO system.

a) – Connection of 2 heating circuits

Pump
P1

First floor

*boiler connection

Pump
P3

Clutch

Mixing valve

Pump
P2

RT1
Ground floor
RT2

L AC 230V N PE

PE P3
NL

*boiler connection

NC COM NO N L3 PE PE PE PE N L
BOILER MAIN PUMP POWER SUPPLY

ECB02M230

CIRCUIT 1

CIRCUIT 2

NL

TK TK L1 N N L

TK TK L2 N

NL

LN

P1 NO

PE COM

LN

P2

PE

NO

868MHz

RT1

RT2

b) – Connection of 2 underfloor heating zones

Mixing valve

Mainfold

P3
M1 M1 M2 M2

*boiler connection

L AC 230V N PE
*boiler connection

RT1

RT2

PE P3
NL

NC COM NO N L3 PE PE PE PE N L
BOILER MAIN PUMP POWER SUPPLY

ECB02M230

CIRCUIT 1

CIRCUIT 2

NL

TK TK L1 N N L

TK TK L2 N

LN
M1 M

LN
M2 M

N L NO

COM NO

RT1

RT2

Boiler *- ON/OFF contacts (according to the boiler’s manual)
Mixing valve

Pump Valve actuator

Legend
Hydraulic coupling
Radiator heating Underfloor heating

– Fuse L, N – 230V AC power suply COM, NO, NC – Voltage-free output RT1 – Circuit 1 thermostat RT2 – Circuit 2 thermostat

P1 – Circuit 1 circulation pump P2 – Circuit 2 circulation pump P3 – Main pump M1 – Circuit 1 actuator M2 – Circuit 2 actuator