ENGO CONTROLS E901 Wireless Programmable Smart Wifi Thermostat
- Product Name: E901 Programmable Wired Thermostat
- Power Supply: 2xAA batteries
- Features:
- 2 types of time schedules
- Possibility to choose hysteresis or built-in TPI algorithm
- Maximum/minimum temperature limitation
- Two relay types: NO (normally open) or NC (normally closed)
- Heating/Cooling modes
- PIN lock
Product Usage Instructions
- The ideal position for thermostat mounting is about 1.5m under floor level, away from heating or cooling sources. Avoid exposing the thermostat to sunlight or extreme conditions like drafts.
- Remove the thermostat cover and batteries if present.
- Use a screwdriver to push the plastic tabs and separate the front part from the back part.
- Fix the back cover to the wall using the supplied mounting screws and connect the wires to the COM/NO connector.
- Use the hinges to fold the back and front covers back into place.
FAQ
- Q: Can I use this thermostat for both heating and cooling systems?
- A: Yes, the thermostat has HEATING/COOLING modes, making it suitable for both types of systems.
- Q: How do I reset the thermostat to factory settings?
- A: To perform a factory reset, refer to section 9 in the user manual for clear step-by-step instructions.
“`
Introduction
1.1 Product Compliance
This product complies with the essential requirements and other relevant provisions of Directives 2014/53/EU and 2011/65/EU.
1.2 Safety Informations
· Before starting installation work and before using the product, read the entire manual. · The information contained in the instructions is essential for proper functioning. · To avoid accidents resulting in personal injury and material damage, please follow all safety precautions, specified in this manual. · The device should not be used by people with limited mental, sensory or mental abilities, without experience, of insufficient knowledge as well as children. · Do not use an unassembled device (eg without a cover). · The device may only be opened by a qualified person. · Keep electrical devices out of the reach of children and ensure that they do not play with it. Children should not be left unattended. If necessary, disconnect the control system for the entire room. · Do not leave the packaging, cabinet, or any loose parts of the device unattended, as they pose a risk to children.
WARNING! · Installation must be carried out by a qualified person with appropriate electrical qualifications in accordance with standards and regulations in force in the given country and in the EU. · Never try to connect the device other than as described in the manual. · Before assembly, repair or maintenance as well as during any connection works it is absolutely necessary disconnect the mains supply and make sure that the terminals and electric wires are not live. · The device may not be exposed to extreme temperatures, strong vibrations or subjected to mechanical shock. · The device should not be used in unfavorable environmental conditions or in rooms where there is a concentration of flammable gases, fumes or dust.
WARNING! · There may be additional protection requirements for the entire installation that the installer is responsible for maintaining.
Care for the natural environment is of paramount importance to us. The awareness that we manufacture electronic devices obliges us to dispose of used electronic components and devices safely. Therefore the company has received a registration number issued by the Chief Inspector for Environmental Protection. The crossed out symbol the trash can on the product means that the product must not be disposed of with ordinary waste containers. Sorting waste for recycling helps to protect the environment. It is the user’s responsibility to surrender used equipment to a designated collection point for recycling waste from electrical and electronic equipment.
Product Overview
E901 is a programmable, surface-mounted electronic room thermostat, used for wireless control of heating devices (e.g. gas, oil boilers, heat pumps) or cooling devices. It has the function of creating your own schedules. Thanks to the built-in algorithms, it offers much better temperature control accuracy than traditional mechanical thermostats. Please read these instructions carefully before using the device for the first time. The thermostat should use 2xAA, 1.5V alkaline batteries. Rechargeable batteries are not allowed.
Product features:
·
has 2 types of time schedules
·
possibility to choose hysteresis or built-in TPI algorithm
·
maximum / minimum temperature limitation
·
two relay types (selectable in thermostat settings): NO (normally open) or NC (normally closed)
·
has the HEATING / COOLING modes
·
PIN lock
4
E901 FULL USER MANUAL
2.1 Package content
1) E901 thermostat 2) Quick Guide 3) 2xAA batteries 4) Mounting screws
1
E901 thermostat
3
2
E901RF | Wireless Programmable Thermostat E901 | Hardwired Programmable Thermostat
Ver. 1 Date of issue: 14 IX 2021 Power supply: 2xAA batteries
Quick Guide
Quick Guide
4
2.2 Proper thermostat location
2xAA batteries
Mounting screws
Please note:
The ideal position to thermostat mounting is about 1,5m under floor level far from heating or cooling sources. Thermostat can’t be exposed to sunlight or any extreme conditions like for example draft.
Because of fire and explosion risk there is not allowed to use thermostat in atmosphere of explosive gases and flammable liquids (eg coal dust). In case if any of listed dangers occur you have to use additional protection measures anti-dust and explosive gases (tight cover) or prevent their formation. Furthermore, thermostat can’t be used in condensation of water vapor conditions and be exposed to water action.
E901 FULL USER MANUAL
5
2.3 Wall mounting
1
2
Remove the thermostat cover as shown in the picture. If there are batteries inside, remove them.
3
Use a screwdriver to push the plastic tabs in as shown in the figure until you feel resistance,
and tilt the front part of the housing.
4
Separate the front part from the back part in the direction shown above.
5
Then fix the back cover to the wall using the supplied mounting screws and the holes provided (see bigger arrows). Connect the wires to the COM / NO connector (see smaller
arrows).
Using the hinges, fold the back and front covers by moving as shown in the picture
above.
6
E901 FULL USER MANUAL
Connection description
a) Connection diagram to gas boiler
AC 230V L
BOILER CONNECTION*
E901
L
3V
COM
2 x AA
NO
N
N
b) Connection diagram to the pump / actuator
AC 230V L
E901
3V
COM
2 x AA
NO
MAX 165 ((35))A A
N
c) Connection diagram to the control box
E901 3V 2 x AA
COM NO
N L SL1
1 – 8 Zones
ECB08M230
control box N SL1
Legend:
Boiler – Boiler connection* – Boiler’s contacts for ON/OFF thermostat (according to the boiler’s instructions)
Pump
Valve actuator
Symbols explanation:
L, N – power supply 230V COM, NO – voltage-free output
– fuse – batteries
E901 FULL USER MANUAL
7
Before you start
Before you start (first power on)
The thermostat is powered by two 1.5V AA alkaline batteries. Insert the batteries into the compartment under the front housing, paying attention to their polarity. The thermostat will start up showing the current software version and then go to the main screen.
1
Reset
PULL OFF THERMOSTAT SLIDE COVER.
2
Reset
INSERT THE BATTERIES, PAYING ATTENTION TO THEIR POLARITY!
3
8
E901 FULL USER MANUAL
Reset
PLACE AND SLIDE THERMOSTAT FRONT HOUSING. THE LCD WILL TURN ON WHEN THE BATTERIES ARE INSERTED.
3
4.1 LCD icon description
7
6 5 4 3 2 1
8 9 10 11 12 13 14
15 16 17 18
1. Program timeline indicator 2. AM/PM 3. Clock 4. Day of the week indicator 5. Settings icon 6. Key lock function 7. Send a signal (pairing)* only E901RF 8. Holiday Mode 9. Low battery indicator
10. Frost Protection Mode 11. Comfort Mode 12. Economic Mode 13. Cooling status 14. Heating status 15. Temperature unit 16. Room / setpoint temperature 17. Temporary override 18. Program number
4.2 Button description
Button
D H M
Function Change the parameter value down Change the parameter value up Set the day of the week Set the hour Set the minutes Comfort temperature Economic temperature / Holiday mode
AUTO AUTO mode / Back button
Programming schedule / schedule type selection
PROG
Confirm button Reset Thermostat’s reboot / Time reset
E901 FULL USER MANUAL
9
Time settings
5. Time settings Day/time settings are set using the D, H and M buttons. Please see steps below how to set time/day:
1
2
Press any button to highlight the display.
3
Pressing D button set the day.
4
3
Pressing H button set the hour.
Pressing M button set the minutes.
10
E901 FULL USER MANUAL
Operation
6.1 Manual mode There are two temperature setpoint levels at our disposal. In manual mode chosen setpoint temperature level is maintained permanently until user changes operation mode or set a different temperature for each level.
– Comfort Mode – in this mode, the thermostat is to maintain a constant day temperature. When the temperature is set manually, e.g. 23°C, the thermostat maintains it until user switches to another operating mode or set a different temperature, e.g. 21°C.
– Economic Mode – in this mode, the thermostat is to maintain the reduced (night) temperature. When the temperature is set manually, e.g. 17°C, the thermostat maintains it until user switches to another mode or set a different temperature, e.g. 19°C.
6.1.1 Comfort mode
In the comfort temperature mode, the thermostat is to maintain a constant day temperature. The comfort temperature level is indicated by sun icon. To set the comfort temperature, see the steps below:
1
2
Press any button to highlight the display.
3
Press button to enter comfort temperature mode. The sun icon should be visible on the display.
4
Using or buttons set new comfort temperature value.
5
3
Confirm by button or wait until the thermostat will approve your choice itself and display the main screen.
The thermostat will return to the main screen and display the actual room temperature.
E901 FULL USER MANUAL
11
6.1.2 Economic mode
In the economic temperature mode, the thermostat is to maintain a reduced (night) temperature. This is to ensure a more economical operation of the heating system when, for example, you are away from home. The economic temperature level is indicated by the moon icon. To set the economic (night) temperature, see the steps below:
1
2
Press any button to highlight the display.
3
Press button to enter economic temperature mode. The moon icon should be visible on the display.
4
Using or buttons set new economic temperature value.
Confirm by button or wait until the thermostat will approve your choice itself and display the main screen.
5
3
The thermostat will return to the main screen and display the actual room temperature.
12
E901 FULL USER MANUAL
6.2 AUTO mode – two schedule types
– AUTO Mode – In the automatic mode, the thermostat maintains the set temperature according to the schedule selected by the user. You can choose from 2 types of schedule to manage the temperature during the week.
6.2.1 First type schedule
First type schedule mode is represented by timeline – 24 hours of a day. Empty,,boxes”means hours where Economic (Moon) setpoint temperature will be maintained, black,,boxes”means hours where Comfort (Sun) setpoint temperature will be maintained.
There are three different configurations in a schedule type 1:
· Two different programs (timelines), separate program for working days (Monday to Friday) and separate program for weekends (Saturday to Sunday) · Individual programs (timelines) for each day of the week · Same program (timeline) for the whole week
6.2.2 Second type schedule Schedule type 2 enables the programming of 6 time intervals per day, with precision up to 10 minutes. Each of the 6 time intervals allows you to set a different temperature (schedule type 1 is limited to switching between two setpoint temperatures (SUN/MOON) at full hours time periods).
When creating a schedule type 2, you must define time and temperature setpoint (thermostat will start to maintain given setpoint temperature from given time setting). There are three different schedule configurations:
· Two different programs, separate program for working days (Monday to Friday) and separate program for weekends (Saturday to Sunday) · Individual programs for each day of the week · Same program for the whole week
Schedule of the second type example
TIME DAYS OF THE WEEK DAYS OF THE WEEK INTERVAL (1 TO 5) MON-FRI (6 TO 7) SAT-SUN
Time 6:00
Time 6:00
P1
Temp. setpoint
Temp. setpoint
21 ° C
18°C
Time 8:00
Time 8:00
P2
Temp. setpoint
Temp. setpoint
14°C
20°C
Time 11:00
Time 11:00
P3
Temp. setpoint
Temp. setpoint
21°C
22°C
Time 13:00
Time 13:00
P4
Temp. setpoint
Temp. setpoint
14°C
20°C
Time 16:00
Time 16:00
P5
Temp. setpoint
Temp. setpoint
21°C
18°C
Time 21:00
Time 21:00
P6
Temp. setpoint
Temp. setpoint
14°C
14°C
DAYS OF THE WEEK (1 TO 5) MON-FRI
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
DAYS OF THE WEEK (6 TO 7) SAT-SUN
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
E901 FULL USER MANUAL
13
6.2.3 Switching between schedules (AUTO Mode) type 1 and 2
1
2
Press any button to highlight the display.
3
5 sec.
Press and hold PROG button for 5 seconds to enter to the schedule type selection.
4
3
Using or buttons choose type of schedule.
Confirm by button. Thermostat will return to the main screen saving chosen type of schedule (timeline will disappear if schedule type 2 is chosen).
14
E901 FULL USER MANUAL
6.3 First type schedule programming
6.3.1 Default program settings (1-3)
Within first type schedule mode there are 9 programs available. Programs 0 to 3 are factory-defined programs that cannot be changed. In this chapter you will find detailed information on the built-in factory programs (1-3) in the E901. These are pre-programmed time settings for the comfort and economy temperature that can be assigned to a selected day. To set up the program, see the steps below. The black squares on the timeline indicate the operating time for the comfort temperature mode, while the absence of them – for the economy temperature mode. Under the chart of each program, there is time (hour) when each mode is active. By default, program 1 is set for each day of the week.
1
2
Press any button to highlight the display.
3
Press PROG button to enter the programming mode.
4
Select the week period using or buttons. Confirm by button.
5
Using or buttons choose program number (0-3). Confirm by button. The thermostat will proceed to
program selection for the next day/days.
6
3
The thermostat will return to the main screen saving the set program.
At the bottom of the display you can see the time line, i.e. the program sequence. Comfortable temperature mode
(sun) is set from 6 to 8 and from 16 to 23 o’clock.
PLEASE NOTE! Programs should be set for all days of the week.
E901 FULL USER MANUAL
15
6.3.2 Choosing and programming user programs (4-9) In order to program your own schedule its necessary to choose user program (4-9), because only user programs are editable. Then we must draw our own timeline using Sun/Moon buttons. Thermostat will be switching between two setpoint temperatures (Comfort and Economy) which are represented by Sun and Moon icons. Switching time is represented by timeline. See steps below how to programm your own schedule:
Example: below, program 4 will be defined for the MON – FR period with a comfort temperature from 8:00 to 16:00 and economic from 0:00 to 8:00 and 16:00 to 0:00. Programming starts from 0:00.
1
2
Press any button to highlight the display.
3
Press PROG button to enter the programming mode.
4
Select the week period (MON-FR) using or buttons. Confirm by button.
Using or buttons choose program number 4.
5
6
Use the button several times to set the economic temperature until 8:00.
From 8:00 to 16:00 set comfort temperature by pressing several times button.
16
E901 FULL USER MANUAL
7
8
Then from 16:00 to 0:00 use the button several times to set the economic temperature.
9
3
The thermostat will proceed to program selection/editing for the next day/days period. Repeat steps 4-8. The
thermostat will save changes and return to the main screen.
Confirm by button.
Please note! Programs 0, 1, 2, 3 are factory set and cannot be edited.
Programs 4 to 9 are user defined (editable). One program (e.g. program 4) can be assigned to several days of the week. If this program is edited, the change affects all days to which given program is assigned to.
E901 FULL USER MANUAL
17
6.3.3 Frost Protection program setting
Frost protection mode (program 0) protects heating system against freezing. It is recommended to set this program if you are planning a long winter trip or if you do not heat up for a long time. The thermostat will maintain a constant temperature of 7°C, thus reducing energy consumption to a minimum.
1
2
Press any button to highlight the display.
3
Press PROG button to enter the programming mode.
4
Select the week period using or buttons. Confirm by button.
5
3
Using or buttons choose program number 0. Confirm by button. The thermostat will proceed to
program selection for the next day/days.
The thermostat will return to the main screen saving the set program. Snowflake – icon will appear on
the display.
PLEASE NOTE! In the frost protection mode, the temperature setpoint can’t be changed and it is maintained constantly at 7°C.
18
E901 FULL USER MANUAL
6.3.4 Temporary override mode When thermostat is running schedule (automatic mode) we can temporarily override it by new setpoint temperature:
1
2
Press any button to highlight the display.
Use or buttons to set the temperature. Confirm by button.
3
4
3
The display will show the,,hand”symbol.
The overwritten temperature is maintained until the next change forced by schedule.
5
3
Then the,,hand”symbol will disappear from the display and the thermostat will return to the automatic mode.
E901 FULL USER MANUAL
19
6.4 Second type schedule programming There are three different configurations in a schedule type 1:
· Two different programs (timelines), separate program for working days (Monday to Friday) and separate program for weekends (Saturday to Sunday) · Individual programs (timelines) for each day of the week · Same program (timeline) for the whole week
Exemplary schedule setting for working days and weekend:
1
2
Press PROG button to enter the programming mode.
3
Select the week period using or buttons. Confirm by button.
4
Using or buttons set the hour for the time period and then confirm by button.
Using or buttons set the minutes for the time period and then confirm by button.
5
3
Use or buttons to set temperature setpoint. Confirm by button. The thermostat will proceed to
program selection for the next time period (a maximum of 6 time periods/switching points can be set).
20
E901 FULL USER MANUAL
6.4.1 Temporary override mode When thermostat is running schedule mode we can temporarily override it by setting new work mode or setpoint temperature:
1
2
Press any button to highlight the display.
3
Using or buttons set temperature setpoint during active AUTO mode.
4
Confirm by button.
The hand icon will be displayed. The temperature will be maintained until
the next change forced by schedule.
E901 FULL USER MANUAL
21
6.5 Party mode In the party mode, the user can override schedule with comfort setpoint temperature by defined number of hours. To do this, follow the steps below:
1
2
Hold the button for 3 seconds.
3
Use or buttons to select the number of hours.
4
3
Confirm by button.
Comfort setpoint temperature will be maintained for defined number of hours. After that thermostat will go back
to AUTO mode (schedule).
The maximum duration of party mode is 9 hours. The temperature setpoint does not change during this mode. When party mode is enabled, pressing SUN, MOON or AUTO button twice (or 3 times if backlight is OFF) will disable it and thermostat will go back to appropriate mode.
To cancel active party mode (example):
1
2
3
To cancel the function, press any button to turn on backlight and then press 2 times button.
The thermostat will stop party mode and will return to schedule (Auto mode).
22
E901 FULL USER MANUAL
6.6 Holiday mode Holiday mode is a special program temperature setpoint which thermostat will maintain for specified days. During holiday mode thermostat is maintaining frost protection setpoint temperature. To set holiday mode, follow the steps below:
1
2
3 sec.
Press any button to highlight the display.
3
Press and hold button for 3 seconds.
4
Use or buttons to select duration of the holiday
mode (in days).
5
6
Confirm by button.
3
Use or buttons to set temperature setpoint which thermostat will maintain for defined number of days. Confirm by button.
TO STOP HOLIDAY MODE:
1
The thermostat is working in holiday mode. Plane icon is on the display.
2
Press button.
3
3
The thermostat will return to the previous mode.
Confirm by button.
E901 FULL USER MANUAL
23
6.7 Key lock function To LOCK the thermostat keys, follow the steps below:
1
3 sec.
3 sec.
Press and hold and buttons for 3 seconds.
To UNLOCK the thermostat keys, follow these steps:
1
3 sec.
3 sec.
Press and hold and buttons again for 3 seconds.
2
3
A lock icon will appear on the screen. The buttons on the thermostat have been locked.
2
3
The lock icon will disappear from the screen. The buttons on the thermostat have been unlocked.
The user has the option to set a PIN code, which he will have to enter each time he wants to unlock the buttons of the thermostat. To set a PIN code, go to parameter P12 (please refer to,,Installer settings”section).
24
E901 FULL USER MANUAL
Installer settings
1
2
5 sec.
Press and hold button for 5 seconds.
You are in the installer mode. Use or buttons to move between parameters. Enter the parameter by button. Edit the parameter using or button. Confirm the new
parameter value with the button.
INSTALLER PARAMETERS:
Pxx
Function
Value
P01
Heating/Cooling mode selection
1
2
P02
Control method temperature
3
4
5
P03
Display temperature
0,5°C
resolution
0,1°C
P04
Offset temperature
-3.5°C to + 3.5°C
NO
P05
Relay type
NC
24h
P06
Clock format
12h
°C
P07
Temperature Scale
°F
P08
Minimum setpoint 5°C – 34,5°C
P09
Maximum setpoint 5,5°C – 35°C
Description
Cooling Heating SPAN ±0,25°C SPAN ±0,5°C TPI for Underfloor Heating TPI for Radiators TPI for Electrical Heating
This parameter specifies the accuracy of the displayed (measured) temperature.
If the thermostat indicates wrong temperature, you can correct it by ± 3.5°C
Normally Open type of relay
Normally Closed type of relay 24 hour 12 hour Celsius Fahrenheit
Minimum heating / cooling temperature that can be set
Maximum heating / cooling temperature that can be set
Default value
1
0,5°C 0°C NO 24h °C 5°C 35°C
E901 FULL USER MANUAL
25
Pxx
Function
Value
NO
P10
Key sound
YES
PIN code.
NO
P11
Require PIN code for editing Service
PIN
Parameters.
P12
Require a PIN code to unlock the,Key Lock’.
NO YES
CLR
Clear settings factory reset
NO YES
Description Off On
Disabled Enabled
Function disabled Function enabled
No action Factory Reset
Default value YES NO NO NO
26
E901 FULL USER MANUAL
Thermostat’s reboot
There is a small hole on the right side of the button. This is the REBOOT button. Pressing this key will restart the thermostat and reset the time.
.
9. Clear settings – factory reset
To perform factory reset (which will remove all user/installer settings), use the CLR parameter from installer parameters menu. After confirming the parameter, the thermostat will restore the default settings.
1
2
Press any button to highlight the display.
3
5 sec.
Press and hold button for 5 seconds.
4
3
Use or buttons to move to CLR parameter.
Confirm the new parameter value with the button.
E901 FULL USER MANUAL
27
Cleaning And Maintenance
The E901 thermostat requires no special maintenance. Periodically, the outer casing can be wiped clean using a dry cloth (please DO NOT use solvents, polishes, detergents or abrasive cleaners, as these can damage the thermostat). There are no user serviceable parts within the unit; any servicing or repairs could only be carried out by ENGO Controls or their appointed agents.
Technical Informations
Power supply Rating max Output signal Temperature range Display temperature accuracy Control algorithm Communication Dimension [mm]
2 x AA batteries 5 (3) A NO/COM relay 5 – 35°C 0.1°C or 0.5°C TPI or Hysteresis: ±0.25°C and ±0.5°C Wired 150 x 84 x 22
84 mm
150 mm
28
E901 FULL USER MANUAL
Warranty
ENGO Controls warrants this product to be free from any defects in material or workmanship and to perform as specified for a period of five years from the date of installation. ENGO Controls reserves the sole responsibility for breach of this warranty by repairing or replacing the defective product. This product includes software that matches the distributor’s identification at the time of sale. The manufacturer / distributor provides a guarantee covering all functions and specifics of the product in accordance with this marking. The distributor’s warranty does not cover the correct operation of the functions and features available as a result of a product software update.
Documents / Resources
![]() |
ENGO CONTROLS E901 Wireless Programmable Smart Wifi Thermostat [pdf] User Manual E901 Wireless Programmable Smart Wifi Thermostat, E901, Wireless Programmable Smart Wifi Thermostat, Programmable Smart Wifi Thermostat, Smart Wifi Thermostat, Wifi Thermostat, Thermostat |