ELSYS PT100 module Technical manual User Manual

Technical Manual
The PT100 module is a module that fits inside the ELT LoRa and is intended for connecting a PT100 platinum sensor with 2- or 4-wire connection.
Features
- Easy use with PT-100 (RTD platinum sensor)
- 2- or 4-wire connection
- Measures -200 to 790 °C
- Fits inside the ELT LoRa box
- Powered by the ELT LoRa internal battery
- Very low energy consumtion
- Terminal block for easy connection

Accuracy (RTD)
± 0.1 °C (-40 to 200°C) + sensor deviation.
± 0.5 °C (full span) + sensor deviation. 2-wire connection 4-wire connection
2-wire connection
4-wire connection
Using the PT100 module with a PT100 RTD
- Set external sensor in the ELT Lo Ra to “PT100”
- Make sure the external period isn’t set to zero.
- Read temperature value in degrees Celsius with data type “External temperature” (0x0C)

Electronic system i Umea AB Tvistevägen 48, 907 36, Umea, Sweden
E-mail: info@elsys.se ǀ Web: www.elsys.se
Specifications in this document are subject to change without notice.
©Electronic system i Umea AB 2023