RCW-260 Temperature Data Logger
“
Specifications:
- Model: RCW-260
- Functions: Temperature, light, vibration monitoring, 4G
network - Sensors: High-precision sensor with high measurement
accuracy - Probe Types:
- RCW-260 T: Built-in temperature
- RCW-260 TH: Built-in T&H
- RCW-260 TE: External + internal temperature
- RCW-260 THE: External T&H+ internal temperature
- RCW-260 TLE: External ultra low T + internal temperature
- Measuring Range: 0%RH~100%RH
Product Usage Instructions:
Safety Instructions:
- Battery: Use original battery only. Do not
disassemble without permission. Avoid squeezing, hitting, heating,
or burning the battery to prevent explosions or fires. - External Power Supply: Use provided power
adapter. Do not use other adapters to prevent device damage or fire
risks. - Device: Do not use in flammable or explosive
gas environments to prevent explosions or fires.
Precautions:
This product integrates temperature, light, vibration
monitoring, and 4G network functions. It uses high-precision
sensors for accurate measurements in various environments. Interact
with the device through the cloud platform or APP to manage
data.
Operative Mode:
- Operate the device using the start-stop button and
activation/flight mode button. - View data on the liquid crystal display including temperature,
humidity, time, and record notes. - Utilize the LED pilot lamp for visual indicators like battery
capacity and alarms.
FAQ:
How do I activate the device?
To activate the device, long press the button for 5 seconds
until the screen appears normally, indicating activation.
Can I use a different power adapter?
No, only use the provided power adapter to avoid damaging the
device or causing a fire.
“`
Repeated RCW-260 instruction manual
Platform login website: https://new.i-elitech.com
Safety Instructions
To ensure installing and using the product correctly, please read carefully and abide by the following instructions:
Battery Please use the original battery rather than any other ones, to avoid possible damage or error to device. Do not disassemble battery without permission. No squeezing, hitting, heating or burning the battery, otherwise battery may explode and lead to a fire.
External Power Supply When need external power supply, please use the provided power adapter. Any other power adapter which does not meet the technical specifications is not allowed. Otherwise, due to which, the device may be damaged, or even cause a fire.
the activity of lithium cell.
Device This device is prohibited to be used in environments with flammable or explosive gas, otherwise, an explosion/fire may be caused. contact manufacturer or supplier.
Precautions
° If the device will not be in use for a long period of time, the device should be removed and stored in the package box in a dry and cool environment.
° even damage the device.
° Do not use the device outdoors, to avoid short circuit, burn, and other malfunctions caused by bad weather such as raining and thunder-lightings.
° networking status.
° Use the data logger within its measurement range. ° Do not impact the data logger with force. °
³ Temperature deviation: Stabilizing time too short for placing the device in the measurement environment. Near or even exposed to a heat/cold source.
³ Humidity deviation: Stabilizing time too short for placing the device in the measurement environment. Long time exposed in steam, fog, waterfall or condensation environment.
³ Pollution: Exposed to dust or other polluted environment.
Product presentation
This product integrates temperature, light, vibration monitoring and 4G network functions. The product adopts high-precision sensor with high measurement accuracy, which can be applied to the collection and monitoring of temperature and humidity data in various complex environments. Interact with the device through the cloud platform or APP to set parameters, view and export data.
Backmounted hanging hole Start-stop button Power supply + data interface Activation / Flight mode button
Liquid crystal display Serial number Built-in sensor External sensor
LED pilot lamp Light sensor
Operative mode Function declaration Airplane mode Signal condition
Battery capacity Light and vibration alarm signs
Time and the number of record notes
Temperature and humidity value
Note: To ensure the reliability of the data, when the battery power is less than 10% to 20%, please do not open the record (20%)
1
Selection table
(standard light and vibration sensors)
Model RCW-260 T RCW-260TH
RCW-260 TE
RCW-260 THE
RCW-260 TLE
Probe Type
Built-in temperature
Built-in T&H
External + internal temperature
External T&H+ internal temperature
External ultra low T + internal temperature
Measuring Range
-30°C~60°C
-30°C ~ 60°C External:-40°C ~ 85°C 0%RH~100%RH Built-in: -30°C ~ 60°C
External:-40°C ~ 85°C Built-in: -30°C ~ 60°C
0%RH~100%RH
External:-200°C ~ 150°C Built-in: -30°C ~ 60°C
Accuracy
±0.5°C
±0.5°C ±5%RH
±0.5°C
±0.5°C ±5%RH
±0.5°C (-40°C~85°C) ±1°C (100°C~150°C)
±2°C (other)
Note: The built-in probe should not be used when charging, so as not to cause abnormal temperature; Do not charge in the environment below 0°C;
Technical parameter
Shock range Light intensity range Resolution ratio Button Led light Display screen Location mode Memory point Shadow data Interrecord gap Upload interval Data upload method Mode of starting freight Freight stop mode Repeat the start Airplane mode Alarm mode Battery type OTA upgrade Classification of waterproof Work environment Storage environment Specification and dimension
0g~16g 0~52000Lux 0.1°C/0.1%RH/0.1g/1Lux Double button design Red and green, red and blue LED indicator lights Broken code display LBS + GPS (optional) 10W Prestant +Afterstop 1min~24h; default: 5min 5min~24h; default: 60min 4G Button pressing, platform, and timing Button, platform, and fill up 3 times (not off shelf life) Key button, timing, electronic fence Overlimit, low power 3.7 V polymer lithium battery 3000mAh Upgrade is available through the data management software and the platform IP65 (built-in) -30°C~70°C, 0% RH~100% RH (no condensation) 15~30°C20~75%RH 103 x 61.3 x 30 (mm)
2
Technical parameter
1.Add equipment Log in the website of the platform: http://new.i-elitech.com, or scan the code to download and install the APP Follow the prompts to register, log in and add devices.
2.Activation Long press the button for 5 seconds, and the
screen appears normally, indicating that the device is activated.
Note: Click the button screen to display normally, indicating that the device is activated;
3.Airplane mode
Open: long press the button for 5 seconds, the screen is successfully started;
display logo indicates that the flight mode
Close: long press the button for 5 seconds, the screen
sign indicates that the flight mode is closed;
Note: For other flight modes, please operate through the platform or APP.
4.Start the record
Press the button for 5 seconds and the screen sign indicates the startup record; if the sign is flashing, the delay countdown state is entered. After the delay, the record starts automatically;
5.Stop recording
Long press the button for 5 seconds, the screen display µsign instructions to stop recording successfully;
3
6.Data export
The device is connected to the computer USB interface through the data cable, and automatically generates data reports in PDF + CSV format. You can copy the generated report to your computer for saving.
Report generation
Device is connected to the computer
The LED indicator light has the instructions
Device Status/Operation Malfunction/Low Battery (below 5%) No Calibration No Activation No Start Start Recording Delayed/Scheduled Start
Recording
Stop Recording
Recording Stopped
Report Generating USB Connecting Clear Report Label Communication Normal Communication Error Start Airplane Mode Stop Airplane Mode Clear the report logo
LED Indicator Display No Flashing Green & Red Flashing x 2 Red & Red Flashing x 2 Green & Red Flashing x 1 Green Flashing x 5 Green to Red Flashing x 1 Green Flashing x 1 (OK) Red Flashing x 1 (Alarming) Red Flashing x 5 Green Flashing x 2 (OK) Red Flashing x 2 (Alarming) Green to Red Flashing x 1 Green & Red On Green & Red Flashing Blue Flashing x 3 Red & Blue Flashing x 3 Blue Flashing x 5 Blue Flashing x 5 At the same time flashing
Triggering Method Short Press Button Short Press Button Short Press Button Short Press Button Short Press Button x 5s
Short Press Button x 10s or Auto Flashing
Long Press Right Button x 5s
Short Press Button
/ Connect USB Long Press Left Button x 5s Flashing When Connecting to Network Flashing When Connecting to Network Long Press Left Button x 5s Long Press Left Button x 5s Long Press Left Button x 5s (USB connected)
4
LCD explicit declaration
Record points Current time Data not uploaded, unable to open
not uploaded points low battery probe fault
5
V 1.3
Documents / Resources
![]() |
Elitech RCW-260 Temperature Data Logger [pdf] Instruction Manual RCW-260 T, RCW-260TH, RCW-260 TE, RCW-260 THE, RCW-260 TLE, RCW-260 Temperature Data Logger, RCW-260, Temperature Data Logger, Data Logger |