Elitech LogEt 6 Temperature Data Logger Instruction Manual

LogEt 6 Temperature Data Logger

Specifications

  • Storage capacity: Not specified
  • Data interface: USB
  • Battery: Not specified
  • Shelf-life: Not specified
  • Battery life: Not specified
  • Communication module/mode: USB
  • Protection grade: Not specified
  • Product dimensions (height*length*width): Not specified
  • Weight: Not specified
  • Work environment: Not specified
  • Physical buttons: Start button, Stop button
  • Alarm method: Not specified
  • Adaptation software: Not specified

Product Usage Instructions

Safety Instructions and Precautions

To ensure safe usage of the product, please adhere to the
following safety instructions:

  1. Use original or technically compatible batteries.
  2. Do not disassemble, squeeze, hit, or heat batteries.
  3. Use the designated power adapter for external power
    supply.
  4. Avoid using the device in flammable or explosive
    environments.
  5. If any unusual odor is detected, disconnect the power supply
    immediately.

Attention

Be mindful of the following factors to avoid errors:

  • Temperature error: Ensure stability in the measurement
    environment.
  • Humidity error: Avoid exposure to moisture for extended
    periods.
  • Pollution: Keep the device away from dusty or polluted
    environments.

Product Overview and Appearance

The product is equipped with physical buttons for operation and
features a display for temperature data and other information.

Operating Instructions

The key functions and status indications are as follows:

  • Start button: Press to display temperature
    data and switch between different information. Hold for 5 seconds
    to start recording.
  • Stop button: Hold for 5 seconds to stop
    recording.
  • Legend status indication: Provides information
    on timed start, recording status, temperature limits, and
    more.

FAQ (Frequently Asked Questions)

Q: What should I do if the device emits an unusual odor?

A: Immediately disconnect the power supply and contact the
manufacturer or supplier for assistance.

Q: How do I start recording on the device?

A: Press and hold the Start button for 5 seconds to initiate
recording.

“`

Multilingual specification
LogEt 6

Directory

1.

01

2. English instruction manual

02

1

2
(),

LogEt 6-85°C PDF16000302

USB LED LCD

///MTK/

/

/ / (**)

LogEt 6 PT / -8550 ±0.5-20~40±1 0.1
16000 USB A LS14250 2 305min USB IP65 100*46*19mm 60g -85°C50°C / LED +

5s 5s
1

1. / 2. 3. 4. 5. 6. 7. MKT 8. 9. 3 10. 2 11. 1 12. 1 13. 2

14. 15. 16. 17. 18.
19. /
20. 21. PDF 22. 23. 24. 25. USB

1 www.e-elitech.com/xiazaizhongxin www.elitechlog.com/softwares
2 USB PDF/
LCD 3 /

*1

1 7( ),
1. 2. 3. 4. 5.()
1
V1.0

Safety instructions and precautions
1. Safety instructions To ensure that you install and use this product correctly, please read and strictly comply with the following terms:

Battery

Please use original or technically compatible batteries. Do not use batteries that do not meet product specifications to prevent damage to equipment or other malfunctions. Do not disassemble, squeeze, hit, or heat batteries privately, and do not place batteries in fire, as this may cause battery explosions and fires

External power supply:
Equipment

When external power supply is required, please use the power adapter configured for this device. Do not use other power adapters that do not meet the external connection technical specifications, otherwise it may damage the instrument and equipment, and even cause a fire power supply
In flammable and explosive gas environments, please use this equipment in accordance with compliance requirements, otherwise it may cause explosions and fires During the use of the device, if the device emits a burnt or other odor, the power supply should be immediately cut off and the manufacturer or supplier should be contacted in a timely manner

2. Attention:
If the equipment is not used for a long time, it should be removed and stored in the packaging box in a dry and cool environment Users are not allowed to make any unauthorized changes to this device. Any unauthorized changes may affect the accuracy of the device and even damage it Do not use the device in harsh environments to avoid instrument short circuits, burns, and other malfunctions caused by adverse weather conditions such as rain and lightning When the recorder is offline (no data upload), please confirm the networking status of the device Please use within the measurement range of the recorder Please mistakenly place the external probe directly in a liquid environment to avoid equipment damage Please do not forcefully impact this recorder The measured values of the recorder may be affected by the following factors
Temperature error: Placed in the measurement environment for too short a stable time Close to heat sources, cold sources, or directly in a water soaked state
Humidity error: Placed in the measurement environment for too short a stable time Long term exposure to steam, water mist, water curtains, or condensation environments
Pollution: Being in a dusty or other polluted environment

1.Product Overview and Appearance
LogEt 6 is a disposable dry ice recorder with a built-in probe. Equipped with ultra-low temperature sensors as standard, the entire machine can directly record temperature in an environment of -85 ° C. It can export reports or automatically generate PDF files through data center software, with 16000 sets of storage, 30 days of battery life, 2 years of shelf life, and support for shadow data function before and after. Widely used in freezers, medical insulation boxes, laboratories, and other scenarios.

æ USB interface ç LED è LCD screen é Stop button

ê Start button ë External probe interface (reserved) ì Battery holder

æ max/min/avr/MTK/log quantity ç upper limit è lower limit é working condition

ê battery level ë Temperature/humidity values ì date í time

2.Model list and specifications
Model List
Model configuration probe Type Main sensor parameters Temperature measurement range Temperature measurement accuracy Temperature resolution
Specifications
Storage capacity Data interface Battery Shelf-life Battery life Communication module/mode Protection grade Product dimensions (height*length*width) Weight Work environment Physical buttons Alarm method Adaptation software

LogEt 6 PT Built in ultra-low temperature (dry ice) temperature sensor -85¥j50¥ ±0.5¥c-20¥~40¥±1¥cother 0.1¥
16000 USB A LS14250 lithium battery 2Years 30Daysclog interval5min USB interface IP65 100*46*19mm 60g -85°Cj50°C Start/Stop LED Elitechlog

3.Operating instructions

Key functions: Start button: In normal display mode, press the start button to display the current temperature, and continue pressing to switch temperature data, date and time, number of records, maximum value, and minimum value; Press and hold for 5 seconds to start recording; Stop button: Long press for 5 seconds to stop recording;
1. Legend status indication:

1. Timed start/Delay start 2. Not start 3. Started 4. Recorded points 5. Maximum temperature 6. Minimum temperature 7. MKT value 8. Average temperature 9. High temperature limit 3 10. High temperature limit 2 11. High temperature limit 1 12. Low temperature limit 1 13. Low temperature limit 2

14. High humidity limit 15. Low humidity limit 16. Maximum humidity 17. Minimum humidity 18. Average humidity
19. Current date 8 time
20. Sensor error 21. PDF generation progress 22. No alarm 23. Alarmed 24. Marked 25.USB communicating

4.Software operation
1. Download software: Download and install the “Jingchuang Data Center” software www.e-elitech.com/xiazaizhongxin (China), www.elitechlog.com/software (other countries)
2. Read data æ Connect the computer using a USB interface ç Open the “Jingchuang Data Center” and wait for the link to complete. è Open the PDF file directly on my computer or open the summary/historical data of “Jingchuang Data Center” to view the data.
Notes: Data can be directly read without the need for the “Jingchuang Data Center” software After the device is taken out of a low-temperature environment, it needs to be left to stand for a period of time and wait for it to return to room temperature before the LCD screen displays data
3. Export data Click on Summary/Historical Data, select Export Data, and choose the format to export
5.Accessories List
Host * 1, instruction manual (electronic version), calibration certificate (electronic version)
6.Warranty and after-sales service
Product warranty: 1 year This product can be returned, replaced or repaired within 7 days from the date of purchase due to performance failure. The warranty period is one year from the date of purchase (based on valid purchase receipts). During the warranty period, any malfunctions caused by quality problems of the product under normal use will be repaired free of charge. The shipping cost for repairing the product shall be borne unilaterally by the sender.
If any of the following situations are met, it is not within the scope of after-sales guarantee: 1. Damage caused by force majeure, such as earthquakes, fires, floods, typhoons, etc; 2. Damage caused by human factors such as improper use, maintenance, and storage by consumers; 3. Damage caused by maintenance, disassembly, etc. by non precision service personnel or authorized service providers; 4. Exceeding the warranty period and scope; 5. Natural wear and tear, consumption, and aging of products (such as shells, cables, etc.).
2
V1.0

Documents / Resources

Elitech LogEt 6 Temperature Data Logger [pdf] Instruction Manual
01, 02, LogEt 6 Temperature Data Logger, LogEt 6, Temperature Data Logger, Data Logger, Logger

References

Leave a comment

Your email address will not be published. Required fields are marked *