effiLUX IPSC4 Strobe Controller

Specifications
- Product Model: IPSC4
- Operating Environment: Well-ventilated places with minimal dust
- Storage Environment: Free from any liquid, chemical product or steam; free from corrosive or combustible gas; not subject to sudden temperature changes
Product Information
The IPSC4 is a high-quality product designed for specific use cases. It is important to follow the general warnings and precautions provided below to ensure safe and efficient operation of the product.
General Warnings and Precautions of Use
Operating and Storage Environments:
- Well-ventilated places with minimal dust.
- Free from any liquid, chemical product, or steam.
- Free from corrosive or combustible gas.
- Not subject to sudden temperature changes.
- Away from water taps, boilers, humidifiers, air conditioners,heaters, or stoves.
User Security:
- Incorrect use of the product may result in fire, electric shock, or other serious damages.
- If an abnormal condition occurs (fuming, heat, noises, etc.), stop using the product immediately and turn the power off.
- Do not disassemble or modify the product.
- Do not look directly at the LED light without protection.
- Do not try to fix any damages on the product by yourself.
- Make sure special protective glasses are used with UV products.
Product Usage Instructions
- Ensure the operating environment meets the specified conditions as mentioned above.
- Before using the product, read through the user manual thoroughly.
- Connect the product to a suitable power source as indicated in the manual.
- Follow any specific instructions for setup or configuration provided by the manufacturer.
- Operate the product according to its intended purpose and recommended guidelines.
GENERAL PRODUCT INFORMATION
Une version française de cette notice est disponible à partir de la page 8 de ce document
Thank you for purchasing an Effilux’s product. To ensure proper use of the product, please read this User manual before use and keep it for your future reference. Any improper use voids the warranty. This product should be used for machine vision and industrial inspection. Do not use the product for other applications, and be sure to follow the instructions below.
Datasheets and drawings in PDF and/or CAD can be downloaded from the Effilux website: www.effilux.com
The label(s) on the product always indicate(s) the reference, the power consumption and the serial number of the product. Be sure to check the content before using the product and handle the label(s) with care. The date of manufacturing is included in the serial number of the product: XXXXXXYYMM-ZZZ with YY corresponding to the year and MM to the month. If the label is missing or damaged and the content cannot be checked, please contact Effilux.
GENERAL WARNINGS AND PRECAUTIONS OF USE
Operating and storage environments
| Operating environment | Temperature: -5 to 50°C – Humidity: 20 to 85RH% (without condensation) – Altitude: Up to 2000m |
| Storage environment | Temperature: -20 to 60°C – Humidity: 20 to 85RH% (without condensation) |
| Informations | Overvoltage category I – Protective class III – Pollution degree 3 |
Except if a specific IP rating is given for your product (refer to the «Dust and Water resistance (IP rating) » section), please install the product in locations under the following conditions (Incorrect installations may cause product failure) :
| Well-ventilated places with minimal dust. | Free from any liquid, chemical product or steam. |
| Free from corrosive or combustible gas. | Not subject to sudden temperature changes. |
| Away from water taps, boilers, humidifiers, air conditioners, heaters or stoves. | |
User security
Incorrect use of the product may result in fire, electric shock, or other serious damages. Please ensure to follow below conditions. If an abnormal condition occurs (fuming, heat, noises, etc.), stop using the product immediately and turn the power off.
| Do not disassemble or modify the product. | Do not look directly at the LED light without protection. |
| Do not try to fix any damages on the product by yourself. | Make sure special protective glasses are used with UV products (<420nm). |
| Do not touch the product with wet hands. | Do not use homemade cables. |
| Wire and keep the flying leads cables in a dry area (regardless of the product’s
degree of protection). |
Make sure the product does not show any moisture or liquid inside before switching it ON. |
| Make sure the power supply and the cable/connector are adapted to the
product specifications. |
The device must be powered by a 24V safety power supply in accordance to local Electrical Safety rules |
| Do not inverse electrical polarity – check your connections and the conventions. | The product packaging must be removed before use. |
VERSIONS & PART-NUMBER
EFFILUX pulse controllers are designed for high throughput vision applications. They can control the power light to create bright flashes of high intensity that will be synchronized with the camera.
The principle is to feed the high-power LED lighting for very short times so as to provide a large amount of light for the time of acquisition.
AVAILABLE ACCESSORIES
Please refer to the datasheet for additional information on the accessories of the EFFI-Dimmer.
GENERAL SPECIFICATIONS
| Power Supply | 24V DC (+/-10%) |
| Power consumption | 132W max |
| Connectors | SUBD |
| Weight | 680g |
| Dimensions | Width x length x height = 56mm x 130mm x 142mm |
| Fastener | 4X M4 holes on the side of the device |
| IP rating | IP54 |
| Operation environment | Temperature: -5°C to 50°C – Humidity: 20 to 85%RH (with no condensation) – Altitude: Up to 2000m |
| Storage environment | Temperature: -20° to 60°C – Humidity: 20 to 85%RH (with no condensation) |
| Informations | Overvoltage category I – Protective class III – Pollution degree 3 |
| Regulations & Marking | CE – UKCA |
| Environmental Standards | RoHS Directives (2011/65/EU, 2015/863/EU and China RoHS) – REACH Regulation – WEEE Regulation |
| Country of Origin | France |
ELECTRICAL INSTALLATION
| Output Connector | ||
| Contact arrangement | Number | Designation |
![]() |
1 | -CH1, Channel 1 |
| 2 | -CH2, Channel 2 | |
| 3 | -CH3, Channel 3 | |
| 4 | -CH4, Channel 4 | |
| 5 | Not connected | |
| 6 | Not connected | |
| 7 | Analog ID | |
| 8 | Signal GND (GND for signals 7,9,10) | |
|
9 |
Trigger Output Digital Signal, 3.3V LVTTL level | |
| 10 | Digital ID (1-Wire EEPROM interface, 3.3V LVTTL level) | |
| A1 | 12V – 24V DC, max 0.5A (for lighthead cooling fan) | |
| A2 | Power GND | |
| A3 | +V, Common Output voltage | |
SOFTWARE
The included software ScLibClient allows users to set the LED lighting: current / Running mode / On Time / OFF Time. The sofware can be downloaded from EFFILUX website.
IP Adress
You need to know the PC IP adress to connect the EFFI-IPSC4.


Running mode
You can choose the running mode.

| Running mode | Trigger setting by the software |
| Off | OFF |
| External Trigger | « On Time » + « Trigger Edge » + External trigger |
| Continuous | Continuous |
| Software Trigger | « On Time » + « Test SW Trigger » |
| External Switch | Full external setting
by GBF |
| Internal Trigger | « On Time » + « Off Time » |
Settings

- Connect the EFFI-IPSC4
- Allocated IP adress (las number different for each EFFI-IPSC4 + indicate «group ID»
- Choose running mode
- Indicate Trigger setting
- Indicate current for each channel
- Indicate Voltage output
- Do not check «Optimal Autosense»
- «Send broadcast»
- To switch off: Choose «Running mode»: OFF, then «Send Broadcast»
Send settings
After you have configured setting, you need to send the setting to the LED Lighting.

MECHANICAL CONSIDERATION
| Weight | 680g |
| Dimensions | Width x length x height = 56mm x 130mm x 142mm (Drawings page 4) |
| Fastener | 4X M4 holes on the side of the device |
| IP rating | IP54 |

REGULATIONS COMPLIANCY
| Regulations & Marking | CE – UKCA |
| Environmental Standards | RoHS Directives (2011/65/EU, 2015/863/EU and China RoHS) – REACH Regulation – WEEE Regulation |
| Country of Origin | France – Manufactured by Effilux |
ENVIRONMENTAL REGULATIONS
EU RoHS Directive
The EU RoHS Directive is short for the «Restriction Of use of certain Hazardous Substances in electrical and electronic equipment». The EU RoHS Directive (2011/65/EU) restricts the use of specifics hazardous substances for the new electronic equipment marketed in the EU. The Directive (EU) 2015/863 amending 2011/65/EU was published in 2015 to restrict the use of specific hazardous substances, including six conventional substances, lead (<0.1%), mercury (<0.1%), cadmium (<0.01%), hexavalent chromium (<0.1%), polybrominated biphenyl (PBB) (0.1%) and polybrominated diphenyl ether (PBDE) (<0.1%), as well as four substances (phthalate compounds), bis(2-Ethylhexyl) phthalate (DEHP) (<0.1%), benzyl butyl phthalate (BBP) (<0.1%), dibutyl phthalate (DBP) (<0.1%), diisobutyl phthalate (DIBP) (<0.1%). Our products do not contain the above certain hazardaous substances in excess of the maximum permitted concentration. However, this does not apply if the product falls under the exemption.
China RoHS
China RoHS Directive is formally known as «Management Methods for Restricting Hazardous Substances Used in Electric and Electronic Products», which was implemented on July 1rst, 2016 in China. Same as EU RoHS Directive (2011/65/EU), this regulation restricts the usage of same six substances. This regulation requires electronic information products which are manufactured or imported, and sold in China, to clearly disclose contents of the 6 restricted substances listed below.

WARRANTY
EFFILUX products come with a warranty of 2 years (one year for radiant quantity), starting from EFFILUX shipping date. Any improper use voids the warranty.
Exceptions: UV products (<420nm): 1-year warranty / Chillers: 1-year warranty / Polarizers are excluded from warranty.
For more information, please refer to the warranty information available on Effilux’s website.
CONTACT INFORMATION
Please refer to the specific documentation (datasheet, user manual and drawing) for complementary information. Contents of this document are based on information available as of July 2025 and may be changed without prior notice.
EFFILUX
1, Rue de Terre Neuve
Mini Parc du Verger – Bâtiment E 91940 Les Ulis – FRANCE
Tel: +33 9 72 38 17 80 Fax: +33 9 72 11 21 69 Mail: sales@effilux.fr
UK Importer: Gardasoft Vision Ltd. Trinity Court, Buckingway Business Park Swavesey, Cambrige CB24 4UQ UK
Frequently Asked Questions
What should I do if I encounter abnormal behavior while using the product?
If you notice any abnormal behavior such as fuming, heat, noises, etc., immediately stop using the product and turn off the power. Refer to the user manual for troubleshooting steps or contact customer support for assistance.
Documents / Resources
![]() |
effiLUX IPSC4 Strobe Controller [pdf] User Manual IPSC4, IPSC4 Strobe Controller, Strobe Controller, Controller |