EC-RF620A-XX Dual Channel Reader
“
Specifications:
- Working frequency band: 840MHz~960MHz
- Support protocol: ISO 18000-6C/EPC C1G2
- Working mode: Frequency hopping
- Output power: Up to 500mW
- Reading and writing distance: More than 3 meters (related to
antenna and tag specifications) - Working power supply: DC 7V-30V, 1A
- Maximum power dissipation: 2W
- Working temperature: -25°C to +70°C
- Storage temperature: -40°C to +85°C
- Working humidity: 10%-95% RH (No condensation)
- Communication interface: RS232/RS485 (optional)
- Size: 76mm x 44mm x 20mm
Product Usage Instructions:
1. Power Connection:
Connect the external DC7-30V power adapter to the POWER
interface on the device.
2. RS232 Interface:
Connect the RS232 interface for data communication. Refer to the
DB9 interface pin definitions for proper connection.
3. Antenna Connection:
Connect the antenna to the ANT1 or ANT2 interface using an SMA
connector. Only connect the RF terminal to the antenna in use to
avoid damaging the device.
4. LED Display:
Monitor the LED display on the front of the device for status
indications. Red light indicates no data upload, green light
flashing indicates data upload, and blue light flashing indicates
software upgrade in progress.
Frequently Asked Questions (FAQ):
Q: What is the operating frequency of the EC-RF620A-ZM
dual-channel reader?
A: The operating frequency of the reader is between 840MHz and
960MHz.
Q: What communication interfaces are supported by the
reader?
A: The reader supports RS232 and RS485 interface data
communication.
Q: What are the dimensions of the EC-RF620A-ZM dual-channel
reader?
A: The reader has dimensions of 76mm x 44mm x 20mm.
“`
EC-LINK Automation (Shenzhen) Co. Ltd.
EC-RF620A-XX Dual-channel reader
EC-RF620A-ZM is a dual-channel fixed UHF FRID reader introduced by EC-LINK, which complies with the ISO 18000-6C standard. Its operating frequency is 840MHz~960MHz. It has a compact appearance and outstanding reading and writing performance. It supports RS232 and RS485 interface data communication.
The reader can be widely used in automation production line management, retail logistics center management, enterprise transportation management and warehousing logistics management and other fields.
ADD:1102, Building 5, Futong Haizhi Technology Park, No.17, Bulan Road, Xialilang Community,
Nanwan Street, Longgang District, Shenzhen
http://www.eclinksz.com
Tel:0086-755-8368 1813
Fax:0086-755-8323 5833
E-mail:sales@eclinksz.com
EC-LINK Automation (Shenzhen) Co. Ltd.
1Product features
Working frequency band: 840MHz~960MHz Support protocol: support ISO 18000-6C/EPC C1G2 Working mode: frequency hopping Output power: up to 500mW Reading and writing distance: more than 3 meters, related to antenna and
tag specifications. Working power supply:DC 7V-30V1A Maximum power dissipation2W Working temperature -25- +70 Storage temperature-40- +85 Working humidity1095RH No condensation Communication interface RS232RS485 is optional Size76X44X20mm
2Interface definition
1POWER Interface, external DC7-30V power adapter 2DB9 interface, connector definition:
DB9 interface definition
Pin
Definition
Illustrate
1
NC
Hang in the air
2
RS_232 TXD RS_232 send signal
3
RS_232 TXD RS_232 receiving signal
4
NC
Hang in the air
5
GND
Data ground
6
NC
Hang in the air
7
NC
Hang in the air
ADD:1102, Building 5, Futong Haizhi Technology Park, No.17, Bulan Road, Xialilang Community,
Nanwan Street, Longgang District, Shenzhen
http://www.eclinksz.com
Tel:0086-755-8368 1813
Fax:0086-755-8323 5833
E-mail:sales@eclinksz.com
EC-LINK Automation (Shenzhen) Co. Ltd.
8
NC
9
NC
Hang in the air Hang in the air
3ANT1, ANT2 interface, SMA connector, connect antenna
Note: The RF terminal is only connected to the antenna that needs to be used. Please do not open the software for unconnected antennas, otherwise empty space may damage the reader/writer!
3Human-machine interface requirements:
There is an LED display light on the front of the read-write host, which is defined as
follows:
Pilot lamp
Define
Led
Red light on – indicates no data has been uploaded (label not read)
Led
Green light flashing – indicates data upload (reading label data)
Led
Blue light flashing – indicates software upgrade in progress
ADD:1102, Building 5, Futong Haizhi Technology Park, No.17, Bulan Road, Xialilang Community,
Nanwan Street, Longgang District, Shenzhen
http://www.eclinksz.com
Tel:0086-755-8368 1813
Fax:0086-755-8323 5833
E-mail:sales@eclinksz.com
EC-LINK Automation (Shenzhen) Co. Ltd.
4Drawing
caution
This device must be professionally installed
This equipment does not allow any antenna to work with the transmitter; the permitted antenna type must be specified external antennas, for example (antenna name:Planar RFID antenna,Model:EC-UHF-ANT-NF0011)
device is generally for industrial/commercial use. it must be sold to authorized dealers or installers only,cannot be sold via retail to the general public or by mail order.
The equipment is an RFID technology RF product, and must be installed by electrical and electronic professionals with a professional certificate
ADD:1102, Building 5, Futong Haizhi Technology Park, No.17, Bulan Road, Xialilang Community,
Nanwan Street, Longgang District, Shenzhen
http://www.eclinksz.com
Tel:0086-755-8368 1813
Fax:0086-755-8323 5833
E-mail:sales@eclinksz.com
EC-LINK Automation (Shenzhen) Co. Ltd.
FCC Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. RF warning for Mobile device: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with
ADD:1102, Building 5, Futong Haizhi Technology Park, No.17, Bulan Road, Xialilang Community,
Nanwan Street, Longgang District, Shenzhen
http://www.eclinksz.com
Tel:0086-755-8368 1813
Fax:0086-755-8323 5833
E-mail:sales@eclinksz.com
EC-LINK Automation (Shenzhen) Co. Ltd.
minimum distance 20cm between the radiator & your body.
IC Caution.
CAN ICES-003(B) / NMB-003(B)
RSS-Gen Issue 3 December 2010″&”CNR-Gen 3e éditionDécembre 2010:
– English: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. – French: Le présentappareilestconforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitationestautorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareildoit accepter tout brouillageradioélectriquesubi, mêmesi le brouillageest susceptible d’encompromettre le fonctionnement.
ADD:1102, Building 5, Futong Haizhi Technology Park, No.17, Bulan Road, Xialilang Community,
Nanwan Street, Longgang District, Shenzhen
http://www.eclinksz.com
Tel:0086-755-8368 1813
Fax:0086-755-8323 5833
E-mail:sales@eclinksz.com
Documents / Resources
![]() |
EC LINK EC-RF620A-XX Dual Channel Reader [pdf] User Guide ECRF62A, 2A83H-ECRF62A, EC-RF620A-XX Dual Channel Reader, EC-RF620A-XX, Dual Channel Reader, Channel Reader, Reader |