WI-FI-Module performance parameter

Nominal Voltage 5V
Connection Type Wi-Fi/Bluetooth
Protocol 802.11 B/G/N20
Channel 1-14@2.4GHz (CH1-11 for US/CA, CH1-13 for EU/CN)
Output Power +20dBm
User Manual
Safety Precautions

Warning Symbol c8 Warning

  1. Please do not put the system into water or fire, in case of explosion or any other situation that might endanger your life.
  2. Please connect wires properly while installation.
  3. Please do not stab, hit, trample or strike the system in any other way.
  4. Please use dry powder extinguisher to put out the flame when encountering a fire hazard, liquid extinguisher could result in the risk of secondary disaster.
  5. For your safety, please do not arbitrarily dismantle any component in any circumstances unless a specialist or an authorized one from our company, device breakdown due to improper operation will not be covered under warranty.

Warning Symbol c8 Caution

  1. We have strict inspection to ensure the quality when products are shipped out, however, please contact us if case bulging or another abnormal phenomenon.
  2. For your safety, device shall be ground connected properly before normal use.
  3. To assure the proper use please make sure parameters among the relevant device are compatible.
  4. Please do not mixed-use batteries from different manufacturers, different types and models, as well as old and new together.
  5. Ambient and storage method could impact the life span and product reliability, please consider the operation environment abundantly to make sure device works in proper condition.
Preface
Manual description

The Wi-Fi module, also known as the serial wi-fi module, belongs to the Transmission layer of the Internet of Things, and its function is to convert the serial port or TTL level into an embedded module that complies with wi-fi wireless network communication standards. It is equipped with ieEE802.11B.G.N protocol stack and TCP/IP protocol stack. Traditional hardware devices embedded with Wi-Fi modules can directly use Wi-Fi to connect to the Internet, which is an important part of the implementation of wireless smart home, M2M and other Internet of Things applications, and is an important component of intelligent hardware.

This platform is the third generation photovoltaic monitoring operation and maintenance platform, through which you can manage the power station more conveniently. This operation guide will guide you to log in your account, create a power station, add equipment, and authorize users, so that you can get started as soon as possible.

This document describes in detail the basic structure, parameters, installation, and operation of the device.

1. Introduction

1.1. Brief Introduction

Dyness Wi-Fi module System is a very convenient product. The addition of Wi-Fi System makes the battery more intelligent. The users can monitor the battery data through Dyness Smart Pro APP anytime and anywhere, which is very convenient.

1.2. Product Properties

The WIFI-module System’s features as below:

  • Built-in low power KM4 MCU, can also be used as application processor
  • Frequency 100 MHZ, Operating voltage: 4.5V-5.5V
  • Wi-Fi / Bluetooth connectivity
  • 802.11B/G/N20, channel 1-14@2.4GHz (CH1-11forUS/CA,CH1-13for EU/CN)
  • support Bluetooth 4.2 Low Energy
    +20dBm output power in 802.11b mode
  • SmartConfig (for Android and IOS devices)
  • External IPEX FPC antenna
  • CE, FCC certification
1.3. Product identity definition
Caution 179 Be careful with your actions and be aware of the dangers
INSTRUCTION Manual Read the user manual before using
Disposal Icon 8 The WIFI Systems cannot be put into the garbage can and must be professionally recycled
Recycle Icon 13 After theWIFI-M01 System life is terminated, the WIFI-M01 System can continue to be used after it recycled by the professional recycling organization and do not discard it at will
CE Icon This WIFI Systems product meets European directive requirements
FCC Icon 1 This WIFI Systems product meets USA directive requirements

2. Product Specification

2.1. Size

Table2-1   WIFI-Module performance parameter

DYNESS DL5.0C Wi-Fi Loger Stick - 2

2.2. Performance Parameter

Table2-2   WIFI-Module performance parameter

Nominal Voltage 5V
Connection Type Wi-Fi/Bluetooth
Protocol 802.11 B/G/N20
Channel 1-14@2.4GHz (CH1-11 for US/CA, CH1-13 for EU/CN)
Output Power +20dBm
2.3. Interface Definition

WIFI-Module product panel interface configuration and function. This section details the interface functions of the front panel of the device.

2.3.1. Figure2-3.1 WIFI-Module Front Panel of battery module

DYNESS DL5.0C Wi-Fi Loger Stick - 1

After connecting the acquisition rod to the equipment, check the status of COM light, NET light and STAT light and whether there is data on the platform.

When the router is connected to the network normally, the normal operation status of the collection rod after power on:

  1. COM light is always on, and the acquisition rod is connected to the device successfully
  2. NET light is always on after the collection rod is powered on (the server connection is successful)
  3. STAT light flashes (acquisition rod works normally)
ID Meaning of LED Status Description
COM Communication status between collector and equipment
  1. The light is always on: the collection rod and the equipment are connected.
  2. The lamp is off: the connection between the collecting rod and the equipment fails. 
  3. The lamp is on for 1s/off for 1s (slow flashing): the acquisition rod is communicating with the equipment.
NET Communication between collector and router state
  1. The lamp is off: the router connection failed.
  2. Lights on for 1s/lights off for 1s (slow flashing): the router is connected successfully.
  3. The light is always on: the server connection is successful. 
  4. The lamp is on for 100ms/off for 100ms (flash): in the fast distribution network.
STAT Working state of collector
  1. The lamp is off: the collection rod works abnormally.
  2. The light is on for 1s/off for 1s (slow flashing): the collecting rod works normally.
  3. The lamp is on for 100ms/off for 100ms (flash): the collection rod returns to the factory value State.
2.3.2. Communication port Pin Definition

DYNESS DL5.0C Wi-Fi Loger Stick - 3

Foot position Definition
PIN1 5V
PIN2 RXD
PIN3 TXD
PIN4 GND

3. Installation and Configuration

3.1. Ready for installation
3.1.1. Environmental requirements
  • Working temperature: -20°C~+85°C
  • Storage temperature: -10°C~+40°C
  • Relative humidity: 5%~85% RH
  • Elevation: no more than 4000m
  • Operating environment: Indoor installation, sites avoid the sun and no wind, no conductive dust and corrosive gas.
  • And the following conditions are met: Installation location should be away from the sea to avoid brine and high humidity environment; The ground is flat and level; There is no flammable explosive near to the installation places;
    The optimal ambient temperature is 15~30°C.
  • Keep away from dust and messy zones.
3.1.2. Equipment preparation

Equipment that may be used are shown in table 3-1:

Table 3-1

Name
Dyness battery (with Wi-Fi function)
Wi-Fi module
mobile phone (the Dyness smart pro app has been downloaded)
Wi-Fi (2.4GHz)
3.2. Equipment connection
3.2.1. connection preparation

Download the Dyness Smart Pro App from the App Store(iOS) or Scan QR code(Android).

DYNESS DL5.0C Wi-Fi Loger Stick - QR Code DYNESS DL5.0C Wi-Fi Loger Stick - 4

Register after the APP is installed, click “Sign Up”, enter the registration page.

DYNESS DL5.0C Wi-Fi Loger Stick - 5 DYNESS DL5.0C Wi-Fi Loger Stick - 6

After registration, use your account and password to Log In.

3.2.2. steps of connection

APP:

1. Create Plants
Please login account and click ‘Plants’, and click the ‘…’ at the top right to select ’Create Plants’ to enter the power station creation page.

DYNESS DL5.0C Wi-Fi Loger Stick - 7

2. Supplement new power station information
Please complete the power station information according to the prompts.
The more complete the information is, the better it will be for you to manage the power station.
a. Improve basic information
Please follow the prompts to improve the basic information of the power station:
the name, location and time zone of the power station. When completing the basic information on the power station creation page, if you do not create it near the power station, you can click the “Location” column to find the power station location, and the system will automatically match the rest of the information for you.
When creating a power station, the APP client will automatically locate your current location. If you create a power station nearby, you do not need to change the relevant information.
b. system information
Please improve the system information of the power station according to the actual situation of the power station to be created by the user: power station type, grid connection type, installed capacity, azimuth angle, inclination angle, and production date.
TIP: The APP user terminal will display the layout of the power station according to the grid connection type, and analyze the data of the power station according to the installed capacity, so please fill in after confirmation. System information of new power station

DYNESS DL5.0C Wi-Fi Loger Stick - 8

c. other information
Please improve the remaining information according to the actual situation of the user. The more complete the information you input, the better you can manage the power station; The currency unit in the income information will affect the income calculation of the system.
Please confirm.
In order to better handle after-sales problems, please fill in the organization code: EC03B0;

3. User authorization 
Please click the “Plant Visitor” column to enter the email number of the user to be authorized and add it as shown in the figure below to authorize the user.

4. Creation completed
After all the above steps are completed, click “Finish” in the upper right corner to complete the creation of the power station.

5. Add Device
Click the “Add” button below the power station and select the collector model.
You can continue to select the barcode or QR code on the direct scanning equipment to add, or enter the serial number to add.
After inputting the serial number correctly, the equipment can be loaded;
Click the “Finish” button in the upper right corner as shown in the figure below to complete the addition.

DYNESS DL5.0C Wi-Fi Loger Stick - 9 DYNESS DL5.0C Wi-Fi Loger Stick - 10

DYNESS DL5.0C Wi-Fi Loger Stick - 11 DYNESS DL5.0C Wi-Fi Loger Stick - 12

WEB:

1. CreatePlants
Login URL:https://server.dyness-tech.com/, Login account, and click ‘Plants’-‘New Plant’ to create new plant.
(Select the creation page of the plant according to the actual business needs)

DYNESS DL5.0C Wi-Fi Loger Stick - 13

2. Improve the information of new plant
Please complete the information of the power station according to the prompts. The ones with asterisks are required, and the more complete the other information is, the better it will be for you to manage the power station.

DYNESS DL5.0C Wi-Fi Loger Stick - 14

a. Basic information
Please improve the power station system information according to the actual situation of the power station that the user wants to create: power station type, power station name, grid connection type, installed capacity, and station construction date.
TIP: The web client will display the power station layout according to the grid connection type, and analyze the power station data according to the installed capacity, so please fill in after confirmation.
b. Other information
Please improve the remaining information according to the actual situation of the user. The more complete the information you input, the better you can manage the power station; The currency unit in the income information will affect the income calculation of the system. Please confirm.
c. Position setting
After completing the power station information, directly click Next in the lower right corner. To set the location, you can enter the location to search directly.
d. Add Visitors
Enter the guest mailbox to add a guest. In order to better handle after-sales problems, please fill in the organization code: EC03B0.

DYNESS DL5.0C Wi-Fi Loger Stick - 15

All information is completed, click Submit, and the power station is created successfully.

3. Add Device
As shown in the figure below, please click “New Collector” on the detail page of the power station.

DYNESS DL5.0C Wi-Fi Loger Stick - 16

DYNESS DL5.0C Wi-Fi Loger Stick - 17

Select the equipment model in the pop-up dialog box and correctly fill in the equipment serial number you want to add.
After confirmation, submit it.

DYNESS DL5.0C Wi-Fi Loger Stick - 18

3.2.3. steps of connection

1. Insert the module into the battery USB port as shown in the figure, Press and hold the white reset button for 2-3 seconds, then release it, and the net light flashes in the distribution network mode.

DYNESS DL5.0C Wi-Fi Loger Stick - 19

2. Open the APP and switch to the “Me” page after login, Click “Config Network”, select the wireless network, enter the password, and scan the SN number of the collector to be distributed.

DYNESS DL5.0C Wi-Fi Loger Stick - 20 DYNESS DL5.0C Wi-Fi Loger Stick - 21

3. Click the “Start Config” button to configure the network, and wait for the configuration to succeed.

DYNESS DL5.0C Wi-Fi Loger Stick - 22 DYNESS DL5.0C Wi-Fi Loger Stick - 23

4. Serial Number

The SN code of the WIFI module is shown in the figure below.

DYNESS DL5.0C Wi-Fi Loger Stick - 24

5. Troubleshooting

Table4-1   WIFI-Module troubleshooting

Trouble Indicate Troubleshooting
COM OFF Abnormal communication of WIFI module Check whether the connection between the collection rod and the equipment is abnormal, and re plug the collection rod.
SATA Slow flash
COM ON Abnormal communication between acquisition rod and route
  1. Check whether the wireless network is configured 
  2. Router signal problem. It is recommended to improve the routing signal strength
NET OFF
SATA Slow flash
COM ON The connection between the collection rod and the route is normal, but the connection with the remote server is abnormal
  1. Check whether the router can access the Internet 
  2. Check the router settings to see if connections are restricted
  3. Contact after-sales to solve the problem
NET Slow flash
SATA Slow flash
COM OFF Abnormal power supply
  1. Check the connection status and plug it again.
  2. Contact after-sales to solve the problem
NET OFF
SATA OFF

19 Hayezira St. Industrial Zone Ramla 7255616          Technical support *2023

www.telran.co.il | office@telran.co.il | fax. 03-5214524 | phone: 03-5575110

Documents / Resources

DYNESS DL5.0C Wi-Fi Loger Stick [pdf] User Guide
DL5.0C Wi-Fi Loger Stick, DL5.0C, Wi-Fi Loger Stick, Loger Stick, Stick

References

Leave a comment

Your email address will not be published. Required fields are marked *