Key Features

  • Adapter strand 2 for functionalization of heliX® Adapter Chip Spot 2.
  • Compatible with heliX® Adapter Chip.
  • Includes Adapter strands for 50 regenerations.
  • Ideal for MIX&RUN sample preparation.
  • Adapter strand 2 carries a hydrophobic red dye (Rc) with a neutral net charge.

heliX® Adapter Chip Overview

2 spots with 2 different anchor sequences for DNA-encoded addressing.

dynamic-BIOSENSORS-heliX-plus-Adapter-Strand 2-1

Product Description

Order Number: AS-2-Rc-lfs
Table 1. Contents and Storage Information

Material Cap Concentration Amount Buffer Storage
Adapter strand 2 – Rc – lfs White 200/250 nM 5 x 200 µL TE40 [1] -20°C

For research use only.
This product has a limited shelf life, please see expiry date on label.
To avoid many freeze thaw cycles please aliquot the nanolever.

Preparation | MIX&RUN

In-solution hybridization of adapter and ligand strands:

  1. Mix Adapter strand 1 – Rc (400 nM) and conjugated Ligand strand (500 nM) at 1:1 ratio (v/v).
  2. Incubate the solution of step 1 at RT at 600 rpm for 30 min to ensure complete hybridization.
  3. Mix solution of step 2 and Adapter strand 2 – Rc – lfs (200 nM) at 1:1 ratio (v/v).
    Solution is ready to use for biochip functionalization.
    Stability of the solution is related to the stability of the ligand molecule.

dynamic-BIOSENSORS-heliX-plus-Adapter-Strand 2-2

Table 2. Additional material for functionalization of spot 1 and reference spot 2.

Material Concentration Buffer Related Product Name Order No
Adapter strand 1 – Rc 400 nM TE40 [1] Adapter strand 1 with red dye Rc AS-1-Rc
Ligand strand

carrying the conjugated ligand

500 nM 2P] E40 [ heliX® Amine Coupling Kit 1 HK-NHS-1

Example
Required volume for 3 functionalizations: 100 μL with a final concentration of 100 nM.

Vial 1 Vial 2
Adapter strand 1 – Rc

(400 nM)

Conjugated Ligand strand

(500 nM)

Adapter strand 1 – Rc – lfs

(200/250 nM)

25 µL 25 µL 50 µL

After incubation time, mix vial 1 and vial 2 to obtain 100 μL of ready-to-use DNA solution.

Contact

Dynamic Biosensors GmbH
Perchtinger Str. 8/10
81379 Munich
Germany

Dynamic Biosensors, Inc.
300 Trade Center, Suite 1400
Woburn, MA 01801
USA

Order Information order@dynamic-biosensors.com
Technical Support support@dynamic-biosensors.com
www.dynamic-biosensors.com

Instruments and chips are engineered and manufactured in Germany.
©2024 Dynamic Biosensors GmbH | Dynamic Biosensors, Inc. All rights reserved.

  1. TE40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA, 50 μM EGTA
  2. If the protein is not stable in PE40 (TE40, HE40), please check buffer compatibility with the switchSENSE® compatibility sheet.

www.dynamic-biosensors.com

Documents / Resources

dynamic BIOSENSORS heliX plus Adapter Strand 2 [pdf] User Manual
AS-2-Rc-lfs v5.1, heliX plus Adapter Strand 2, Adapter Strand 2, Strand 2
dynamic BIOSENSORS heliX plus Adapter Strand 2 [pdf] User Manual
heliX plus Adapter Strand 2, heliX plus, Adapter Strand 2, Strand 2

References

Leave a comment

Your email address will not be published. Required fields are marked *