Instructions for converting Daviteq
Sigfox Exd-Pressure device to
Daviteq LoraWAN Exd-Pressure device.
Prepare tools:
- 1 pc x Screwdriver
- 1 pc x 12” Wrench
- 1 tube x Thread Lock Glue
- 1 bottle x Cleaning alcohol
- 1 pc x Cleaning cloth
- 1 pc x Grinding tool
- 1 pc x Heat gun
Disassemble the Daviteq Sigfox Exd Pressure device:
- Step 1: Unscrew the antenna by turning the antenna counter-clockwise and open the device housing cover by turning the upper housing cover counter-clockwise as a below figure.
- Step 2: Grind the excess part inside the housing cover to fit with new LoraWAN main board by grinding tool.
- Step 3: Remove the Sigfox mainboard by screwdriver. The position of 3 screws is marked as Figure 2.3.
- Step 4: Unscrew the antenna cable and cut out the 2 wires connecting the pressure sensor and Sigfox mainboard.
- Step 5: Heat up the connecting thread between the pressure sensor and housing by heat gun (recommended heat with temperature of 300 oC in 20-30 minutes) to melt the thread lock glue for easy disassembling. Then unscrew the sensor by turning counterclockwise using wrench.
- Step 6: Peel off all labels on the housing of Sigfox device.
- Step 7: Clean the housing and thread by alcohol and cloth.
Assemble the Daviteq LoraWAN Exd Pressure device:
Note: Only re-use housing, antenna for converting from Sigfox device to LoraWAN device. DON’T re-use the Sigfox mainboard and pressure sensor.
- Step 1: Apply thread lock glue to the connection thread and screw the new pressure sensor to the housing by turn clockwise.
Warning: Do not use to too much glue as it will take too long to dry and leak to the mainboard. Recommend using 2-3 drops of glue.
- Step 2: Select correct LoraWAN mainboard for the sensor in the step 1:
– 10 bar new sensor will be installed with LoraWAN mainboard having item code on the main board label of WSLRWEX-PPS-10-01
– 100 bar new sensor will be installed with LoraWAN mainboard having item code on the main board label of WSLRWEX-PPS-100-01 - Step 3: Note out the serial number on the selected LoraWAN mainboard label for later usage in labelling step.
- Step 4: Screw the antenna cable on the LoraWAN mainboard to antenna and plug socket of sensor cable to the socket on the LoraWan mainboard.
Warning: Arrange the wires neatly to avoid the wires being stuck.
- Step 5: Fix the LoraWan mainboard to the housing in the position as shown by screwdriver. The position of 2 screws is marked as Figure 3.4.
- Step 6: Stick the sensor manual QRCode label inside the housing cover as Figure 3.5.
https://www.iot.daviteq.com//manual-for-wireless-sensors/manual-for-wslrwex-pps-%7C-fw3
- Step 7: Screw the housing cover and antenna. Make sure Oring is available on housing cover.
Stick labels on the housing of Daviteq LoraWAN Exd Pressure device:
There are 4 types of labels for the LoraWAN Exd Pressure device:
1 x LoraWAN label,
1 x Device information label
1 x Magnet reed-switch label
1 x Manual QRCode of Daviteq LoraWAN Exd Pressure firmware3 device label
And 4 types of label and LoraWAN mainboard in the package.
- Step 1: Screw the housing cover tighty then stick the LoraWAN label vertically. The direction of the label as Figure 4.1.
- Step 2: Stick the device information label at the position at Figure 4.2.
Note: Make sure the serial number on the label is the same as one on the main board label. The serial number on the mainboard label is noted out in step 3 of section “3. Assemble the Daviteq LoraWAN Exd Pressure device”
The the device information label is next to sensor mounting semi-circular hole.
- Step 3: Stick the magnet reed-switch label as position as Figure 4.3.
- After completing labelling, the sensor will be as below figure 4.4.
5. Check operation of the LoraWAN device after converting
- Follow instruction at section 1.7 Guide for Quick Test of WSLRWEX-PPS firmware manual. Link of online manual: https://www.iot.daviteq.com//manual-for-wireless-sensors/manual-for-wslrwex-pps-%7C- fw3
Please note that, log in is required to access the online manual of WSLRWEX-PPS firmware 3. The user needs to visit https://www.iot.daviteq.com to register the user for accessing the online manual.
Revision #13
Created Thu, Jan 25, 2024 2:04 AM by Vũ Hoàng Anh Tài
Updated Wed, Jan 31, 2024 8:44 AM by Phan Van Luc
Documents / Resources
![]() |
Daviteq LoRaWAN Exd Pressure Device [pdf] User Guide LoRaWAN Exd Pressure Device, LoRaWAN, Exd Pressure Device, Pressure Device, Device |