Danfoss TP5001 Programmable Room Thermostat User Guide
Danfoss TP5001 Programmable Room Thermostat

LCD Overview

Symbols Function description Symbols Function description
Mon – Sun Current set day  Symbol Heating active
1 2 3 4 Current on/off period  Symbol Frost protect active
Symbol Current set time / parameter number in setup Symbol Schedule mode
 Symbol Room temperature  Symbol Away mode
 Symbol  Temperature indication  Symbol RF Status (TP5001RF only)
 Symbol Set temperature  Symbol Battery low indicator (TP5001B & TP5001RF only)

LCD Overview

Buttons

Symbols Function description
Symbol Power on/of
Symbol Timer and program operation
M Mode change / option setting
Symbol Mode change / option setting

Power ON/OFF

Turn the thermostat ON or OFF (standby) by pressing Symbol .

Setting the Temperature

  • Press < or > at any time to change the desired temperature value. SET is shown in the display.
  • When releasing < or >, the display returns to showing the actual temperature.
  • The adjustment step is 0.5 °C.

Select Away Mode

  • Press M to enter Away mode and Symbol will be displayed.
  • Away mode temperature can be set in parameter settings, P07.
  • Press M again to exit Away mode.

Set Date & Time

  • Press Symbol ; Year digit Flashes. Press < or > buttons to adjust year.
  • Press again Symbol ; Month digit flashes. Press < or > buttons to adjust month.
  • Press again Symbol ; Day digit flashes. Press < or > buttons to adjust day of the month.
  • Press againSymbol; Hour digit flashes. Press < or > buttons to adjust hour.
  • Pres again: Symbol; Minute digit flashes. Press < or > buttons to adjust minute.
  • Press to exitSymbol , automatic exit after 20 seconds, any changes are retained.

Frost Protection Temperature

  • You can switch the thermostat OFF (Standby) by alternately pressing . In OFF (Standby) mode, the thermostat is set to a Frost Protection temperature setting and will switch On only if the measured temperature falls below this temperature (5 °C by default).
  • The frost protect icon and current temperature will be displayed.

Advanced Programmable Timer

The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is not required.
Example below for 5/2 day setup, 4 Temperature settings.

The function consists of 2 programs:
P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.) P2 with 4 events in 2 days (Sat. Sun.)

P1: Press  for 3 secs to display Mo. Tu. We. Th. Fr.
P1, Event 1:
  1. Use < or > to select the start hour.
  2. Press  to accept the setting
  3. Use < or > to set the minute.
  4. Press  to accept the setting.
  5. Use < or > to select the temperature.
  6. Press  to accept the setting.
    P1, Event 2-4:Repeat the Event 1 procedure for programming Event 2-4.
P2: Sa. Su. are now shown in the display.
P2, Event 1:
  1. Use < or > to select the start hour.
  2. Press  to accept the setting.
  3. Use < or > to set the minute.
  4. Press  to accept the setting.
  5. Use < or > to select the temperature.
  6. Press  to accept the setting.
    P2, Event 2-4:Repeat the Event 1 procedure for programming Event 2-4.

f schedule working mode is set to 24hr, only P1 program will be available, see parameter P01. Mo. to Su. will be set together with the same times and temperatures.
The thermostat will continue the 4-event program based on the present time and day.

To set and change the room temperature temporarily:

  1. Press < or > at any time to change the desired temperature value. SET is shown in the display.
  2. When releasing the < or >, the display returns to showing the actual temperature. This temperature change is only temporary and will be maintained only until the next programmed setting!

A default program provides timer control if the customer does not create own programs:

Days Event 1 Event 2 Event 3 Event 4
Start time Temp. Start time Temp. Start time Temp. Start time Temp.
Mo. – Fr. 6:30 20° C 8:30 15° C 16:30 20° C 22:30 15° C
Sa. – Su. 7:30 20° C 9:30 15° C 16:30 20° C 22:30 15° C

24hr mode default program same as Mo. – Fr. above.

Set Control Parameters

  • • Press M button for 6 seconds to enter the parameter setting mode. Press M for parameter selection and set the parameter range via < or >. Complete all adjustments.
  • To exit press Symbol , which is available for this purpose (automatic exit after 20 seconds with no operation).

The digits indicate the set value as follows:

No. Parameter settings Settings range Default
 P01  Working mode
  1. Manual
  2. Schedule timer 5/2 day
  3. Schedule timer 24hr
 02
P02 Heat control mode
  1. On/off load compensation
  2. On/off standard
01
 P03  Heat control start-up mode
  1. Normal start control
  2. Delayed start control
  3. Optimised start control
 01
P04 Temperature limit high Between low (P05) and 35° C 35° C
P05 Temperature limit low Between 5° C and high (P04) 5° C
P06 Frost protect temperature Between 5° C and 15° C 5° C
P07 Away mode temperature Between low (P05) and high (P04) 18° C
P08 Timer display 01: 24hr02: 12hr 24hr
P09 Service due setup Installer setting only
P10 RF Pairing (TP5001RF only) 00: RF pairing mode off 01: RF pairing mode on 00
P11 Auto daylight saving 01: On02: Off 01

 Error Messages

E1 Sensor failure
EE EEPROM failure
Lo Measured temperature below 0 °C
Hi Measured temperature above 50 °C
E3 RF Pairing failed
E4 RF Signal lost
E6 Real Time Clock (RTC) faliure

Danfoss Limited XA
Climate Solutions danfoss.uk  0330 8086 888  customerservice.uk@danfoss.com Danfoss Ltd., Building 4, Uxbridge Business Park, Sanderson Road, UB8 1 DH, Uxbridge, Buckinghamshire, UK.

Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product.

All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.

Danfoss Logo

Documents / Resources

Danfoss TP5001 Programmable Room Thermostat [pdf] User Guide
TP5001 Programmable Room Thermostat, TP5001, Programmable Room Thermostat, Room Thermostat, Thermostat
Danfoss TP5001 Programmable Room Thermostat [pdf] User Guide
BC337370422703en-000102, 087R1003, TP5001, Programmable Room Thermostat, TP5001 Programmable Room Thermostat, Room Thermostat, Thermostat
Danfoss TP5001 Programmable Room Thermostat [pdf] User Guide
TP5001, TP5001RF, TP5001B, TP5001 Programmable Room Thermostat, Programmable Room Thermostat, Room Thermostat, Thermostat
Danfoss TP5001 Programmable Room Thermostat [pdf] User Guide
BC337370422703en-000102, 087R1003, TP5001 Programmable Room Thermostat, TP5001, Programmable Room Thermostat, Room Thermostat, Thermostat
Danfoss TP5001 Programmable Room Thermostat [pdf] User Guide
TP5001 Programmable Room Thermostat, TP5001, Programmable Room Thermostat, Room Thermostat, Thermostat
Danfoss TP5001 Programmable Room Thermostat [pdf] User Guide
TP5001 Programmable Room Thermostat, TP5001, Programmable Room Thermostat, Room Thermostat, Thermostat