GENERAL DESCRIPTION

This device is a ramped valve driver which accepts a setpoint potentiometer input from a control handle and drives a single coil valve. It is pulse-width modulated and has adjustable acceleration/deceleration ramping. The PWM frequency is selected by a jumper on the terminal strip. The threshold and full stroke forward outputs are adjustable. It does not have a reverse output.

DIMENSION AND CONNECTION DIAGRAM

Danfoss KE07204 Ramped Valve Driver - DIAGRAM

OUTPUT CHARACTERISTICS

SUPPLY VOLTAGE
24 Vdc
PWM FREQUENCY
50 Hz or 30 Hz
OUTPUT CURRENT
800 mA maximum
FACTORY SETTINGS WITH 26 OHM LOAD
Threshold: 250 mA
Full Stroke 600 mA

ADJUSTMENTS\

Danfoss KE07204 Ramped Valve Driver - ADJUSTMENTSK14425 UNIT SPEC