Installation Guide for Danfoss models including: KE07204 Ramped Valve Driver, KE07204, Ramped Valve Driver, Valve Driver, Driver

KE07204 Ramped Valve Driver Installation Guide

PDF preview unavailable. Download the PDF instead.

AN152886482155en-000203
Phased Out Products

3500 Annapolis Lane North, Minneapolis, MN 55447 Telephone: (763) 509-2084 Telefax: (763) 559-0108

Unit Specification
KE07204 Ramped Valve Driver

ISSUE: 1

DATE: May 1993

GENERAL DESCRIPTION

This device is a ramped valve driver which accepts a setpoint potentiometer input from a control handle and drives a single coil valve. It is pulse-width modulated and has adjustable acceleration/deceleration ramping. The PWM frequency is selected by a jumper on the terminal strip. The threshold and full stroke forward outputs are adjustable. It does not have a reverse output.

DIMENSION AND CONNECTION DIAGRAM

THRESHOLD FWD F/S RAMP TIME
1 2 3 4 5 6 7 8 9 10

100,08 (3.94)
88,9 (3.50)

5,59 (0.22) 6,35 (0.25)
20,32 (0.8)

69,85 (2.75) 113,0 (4.45)

3,96 DIA (6) (0.156)
148,59 (5.85)

N/C N/C POT GND GND +24V POWER OUTPUT - FWD POT +8V POT WIPER N/C N/C

FOR 50HZ PWM JUMPER TERMINALS TB1-11 AND TB1-12 FOR 30HZ PWM REMOVE JUMPER
Dimensions in millimeters (inches).
.
OUTPUT CHARACTERISTICS

SUPPLY VOLTAGE 24 Vdc
PWM FREQUENCY 50 Hz or 30 Hz

OUTPUT CURRENT 800 mA maximum
FACTORY SETTINGS WITH 26 OHM LOAD Threshold: 250 mA Full Stroke 600 mA

© Danfoss, 2013-09

K144.25 UNIT SPEC

1687 1

OUTPUT CURRENT - mA

OUTPUT CURRENT - mA

VALVE OUTPUT - % R40 MAX CCW
R40 MAX CW

Phased Out Products

ADJUSTMENTS
2

100 75 50 25

0123456 TIME - SECONDS 1679

1000

FULL CW

800

R18

FACTORY

SETTING

600

FULL CCW
400

200

0

0 12 34 56 78 INPUT VOLTS

Threshold adjustment.

1688

1000

800

FULL CW

600

R30

FACTORY

400

SETTING

FULL

200

CCW

0

0 12 34 56 78 INPUT VOLTS

Full stroke adjustment.

1689

K14425 UNIT SPEC

© Danfoss, 2013-09


Danfoss A/S GPL Ghostscript 9.55.0