Danfoss 103E5 Electronic Time Switch

Danfoss-103E5-Electronic-Time-Switch-product

Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss-103E5-Electronic-Time-Switch-fig-1Installation Instructions

Please Note:
This product should only be installed by a qualified electrician or competent heating installer, and should be in accordance with the current edition of the IEEE wiring
regulations.

Product specification

Specification
Power supply230 Vac ± 15%, 50 Hz
Switching action1 x SPST, Type 1B
Switch rating264 Vac, 50/60Hz, 3(1)A
Timing Accuracy±1 min./month
Power ReserveMinimum 14 days
Enclosure RatingIP30
Max. Ambient Temperature45°C
Dimensions, mm (W, H, D)102 x 136 x 47
Design standardEN 60730-2-7
Control Pollution SituationDegree 2
Rated Impulse Voltage2.5kV
Ball Pressure Test75°C

Installation

NB. For FRU units – go straight to point 6.

  1. Loosen the fi xing screw in the base of the unit to release the Wiring Cover.
  2. Holding the unit face downwards, press fi rmly in the centre of the wallplate and slide it apart and lift it from the module.
  3. Fix the wallplate and terminal block to the wall, or plaster box, as required. Ensure that the screw heads do not protrude beyond the vertical centre rib of the wallplate, or this will prevent the module correctly locating onto the wallplate.
    Danfoss-103E5-Electronic-Time-Switch-fig-2
  4. Surface cables can only enter from below the unit. Cut an appropriate cable aperture in the wiring cover. If the wallplate is mounted on a plaster box, cables can enter from the rear below the terminal block.
  5. Electrical connections are simplifi ed by using a Wirin Centre. However, if this is not used, the wallplate terminal identifi cation is as shown.
    Danfoss-103E5-Electronic-Time-Switch-fig-3If the system being controlled is 230 Vac then terminals 3 and L must be linked with insulated cable capable of carrying full load current. Whilst the unit does not require an earth connection, a terminal is provided on the wallplate for earth continuity purposes.
  6. Referring to the wiring diagrams connect the unit as shown.
  7. Find out from the user whether the unit is required to operate in 24-hour mode (factory preset) or weekday/weekend mode (5/2 day). To convert to 5/2 day mode remove the small two-way connector from the pins towards the left of the recess on the rear of the module, then press the SELECT/ADVANCE/+/- buttons all at the same time to RESET the unit.
  8. Ensure all dust and debris are cleared from the area. Plug the module into the wallplate by locating it onto the wallplate and, when fl ush with it, sliding it down, ensure the hook at the top of the wallplate engages with the slot at the back of the module.
  9. Before setting the programme, check the unit and circuit. Press the SELECT button until the bar in the display lines up with the word ON. Adjust the remote thermostats to check the system operates correctly.
  10. Then press the SELECT button until the bar lines up with the word OFF and check the system does not operate.
  11. When the circuit check has been completed, replace the wiring cover and tighten the fi xing screw. Cut any cable aperture in the wiring cover which may be necessary to accommodate surface mounted cables.
  12. Finally set time of day and programmes required, noting that the unit is supplied with a pre-set programme, as stated on.

Wiring

Danfoss-103E5-Electronic-Time-Switch-fig-4

Typical Gravity DHW with pumped heating

Danfoss-103E5-Electronic-Time-Switch-fig-5

Typical control of Pump for Central Heating on a Solid Fuel System

Danfoss-103E5-Electronic-Time-Switch-fig-6

Typical Heating Only system, Boiler and Pump control

Danfoss-103E5-Electronic-Time-Switch-fig-7

Typical control of Low Voltage System requiring voltage free contacts

Danfoss-103E5-Electronic-Time-Switch-fig-8

Typical control of Heating when provided by Combination type Boiler

Danfoss-103E5-Electronic-Time-Switch-fig-9

Typical Heating & Hot Water control system using 3 port mid-position valve

Danfoss-103E5-Electronic-Time-Switch-fig-10

Replacement

Danfoss-103E5-Electronic-Time-Switch-fig-11 Danfoss-103E5-Electronic-Time-Switch-fig-12

What is a programmer?

Danfoss-103E5-Electronic-Time-Switch-fig-13

The text below has been edited and approved by the Plain English Campaign, who has issued a Crystal Mark to be displayed with it.

What is a programmer?

… an explanation for householders.
Programmers allow you to set ‘On’ and ‘Off ’ time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at different times.
Set the ‘On’ and ‘Off ’ time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off ’ heating periods, or be permanently off . The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched the heating off . And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature.

Please note: A timeswitch is a single channel programmer. It will allow you to set your system’s On and Off periods.

User Instructions

Your timeswitch

Your 103E5 timeswitch controls your hot water and heating together, turning them on and off at the same times.
The 103E5 can provide 3 ON periods and 3 OFF periods each day and can off er either 24 hour control (same programme for each day of the week) or 5/2 day control (one set of programmes for weekdays and a diff erent set for weekends)

Overview

Danfoss-103E5-Electronic-Time-Switch-fig-14

Setting the time & the programme

Before you start

  • Open the flap on the front of the unit.
  • Press all four buttons (SELECT / ADVANCE / + / -) at the same time
  • This will reset the unit, reinstate the preset programmes and set the time to 12:00pm on Monday.Danfoss-103E5-Electronic-Time-Switch-fig-15

Setting the clock

  • Press PROGRAMME once
  • Use + and – buttons to set the correct time
  • When time is correct press PROGRAMME again.Danfoss-103E5-Electronic-Time-Switch-fig-16
  • In 24-hour mode this will take you straight to programming mode, where you can select your own ON and OFF times.
  • In 5/2 day mode this will first allow you to programme the correct DAY. To do this:
    • use the + or – buttons to select the correct day
    • press PROGRAMME again to enter RUN mode

Factory preset programmes

Factory Presets

The unit is supplied with the following preset programme which will be active after the unit has been reset.

 Mon-Fri or All days in 24hr modeSat-Sun* (5/2day mode only*)
1st ON6.30am7.30am
1st OFF8.30am10.00am
2nd ON12.00pm12.00pm
2nd OFF12.00pm12.00pm
3rd ON5.00pm5.00pm
3rd OFF10.30pm10.30pm

N.B. 2nd ON and 2nd OFF are set to the same time. These 2 times are ignored by the programme therefore the heating will just come on once in the morning and once in the evening. If you want the heating to come on in the middle of the day set the 2nd ON and 2nd OFF to the times you require.

Accepting the preset times

  • If you are happy to use the settings above, you don’t need to do anything else.
  • To accept the presets press the PROGRAMME button until the colon in the display begins to flash.
  • Your unit is now in RUN mode.

Programming event times in 24 hour mode

You can programme your timeswitch to come on and go off up to 3 times each day, to suit your requirements.

Danfoss-103E5-Electronic-Time-Switch-fig-17

  • Press PROGRAMME until 1 (Event
    shows along the top of the display.
  • Use the + and – buttons to set the time you want your system to first come on in the morning
  • Press PROGRAMME again to move to the next step (Event
  • Use the + and – buttons to set the time you want your system to first go off.
  • Continue using the PROGRAMME and +/- buttons in this way to set the ON/OFF times for events 3-6 (2nd ON/OFF & 3rd ON/OFF).
    N.B. It is not possible to programme times out of sequence.
    If you do not press a button at all for 3 or 4 minutes the unit will automatically return to RUN mode.

Programming event times in 5/2 day mode

You can programme your timeswitch to come on and go of up to 3 times each day, to suit your requirements, with one set of programmes for weekdays and a diff erent set of programmes for the weekend.

Weekdays (MOTUWETHFR)

Danfoss-103E5-Electronic-Time-Switch-fig-18

  • Press PROGRAMME until 1 (Event 1) shows along the top of the display and MOTUWETHFR shows along the bottom.
  • Use the + and – buttons to set the time you want your system to first come on in the morning.
  • Press PROGRAMME again to move to Event 2
  • Use the + and – buttons to set the time you want your system to first go off.
  • Continue using the PROGRAMME and +/- buttons in this way to set the ON/OFF times for events 3-6 for weekdays.

Weekend (SASU)

Danfoss-103E5-Electronic-Time-Switch-fig-19

  • Press PROGRAMME again until 1 (Event 1) shows along the top of the display and SASU shows along the bottom of the display.
  • Use the PROGRAMME and +/- buttons to set the ON/ OFF times for the weekend.
    If at any time you wish to return to the factory preset programme, press SELECT / ADVANCE / + / – buttons together at the same time to reset the unit.
    N.B. It is not possible to programme times out of sequence.

Running your programme

The 103E5 controls your hot water and heating together, turning them on and off at the same times.
To run the central heating and hot water programme press the SELECT button.

Danfoss-103E5-Electronic-Time-Switch-fig-20

As you press SELECT a bar on the display will move between ON, OFF, ALLDAY and AUTO

RUN mode

  • ON = the hot water/heating will remain on constantly
  • OFF = the hot water/heating will not come on
  • AUTO = the hot water/heating will come on and go off according to the programmed times
  • ALLDAY = the unit will come on at the first programmed ON and will remain on until the last programmed OFF

Select the option you require, depending on your circumstances, time of year, etc.

Temporary User Overrides
Sometimes you may need to change the way you use your timeswitch temporarily, i.e due to unusually cold weather. The 103E5 has two convenient overrides which can be selected without affecting the set programme.

Danfoss-103E5-Electronic-Time-Switch-fig-21

Override buttons

+1HOUR

  • Press +1hour once if you need an extra hour of operation
  • If the system is off it will come on for an hour. If it is already on it will add an extra hour so the system stays on for an extra hour.
  • To cancel the override press +1hour again.

ADVANCE (only during AUTO mode)

  • Press the ADVANCE button once to advance to the next programmed event.
  • If the system is on it will go off . If it is off it will come on. The set programme will resume at the next programmed ON/OFF time.
  • To cancel the override press ADVANCE again.

Battery backup

  • In the event of a power cut, the built-in lithium battery will keep your time and programme settings for up to 15 days.
  • After 15 days without mains power the unit will switch off and two dots will show in the display. However, all your programmed on/off times will be remembered.
  • When the mains power is restored, the unit will need to be reactivated by pressing the PROGRAMME button, and the time and day will need to be set.

Still having problems?

Call your local heating engineer:
Name:
Tel:

For problems relating to your heating controls …

Visit our website:
www.heating.danfoss.co.uk

Email our technical department:
ukheating.technical@danfoss.com

Call our technical department
01234 320 256
(9:00-5:00 Mon-Thurs, 9:00-4:30 Fri)

For a large print version of these instructions, please contact the Marketing Services Department on 01234 364 621.

Danfoss Randall Ltd
Ampthill Road
Bedford
MK42 9ER
Tel: 01234 364621
Fax: 01234 219705

FAQ

  • Your timeswitch is not responding, what can you do?
    If your timeswitch is not responding, check the power supply, reset the unit, and ensure correct programming. If issues persist, contact customer support for assistance.